SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Timmermans Philippe) "

Sökning: WFRF:(Timmermans Philippe)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alexander, Stephen P. H., et al. (författare)
  • The Concise Guide to PHARMACOLOGY 2023/24: G protein-coupled receptors
  • 2023
  • Ingår i: BRITISH JOURNAL OF PHARMACOLOGY. - : British pharmacological society. - 0007-1188 .- 1476-5381. ; 180
  • Tidskriftsartikel (refereegranskat)abstract
    • The Concise Guide to PHARMACOLOGY 2023/24 is the sixth in this series of biennial publications. The Concise Guide provides concise overviews, mostly in tabular format, of the key properties of approximately 1800 drug targets, and about 6000 interactions with about 3900 ligands. There is an emphasis on selective pharmacology (where available), plus links to the open access knowledgebase source of drug targets and their ligands (), which provides more detailed views of target and ligand properties. Although the Concise Guide constitutes almost 500 pages, the material presented is substantially reduced compared to information and links presented on the website. It provides a permanent, citable, point-in-time record that will survive database updates. The full contents of this section can be found at . G protein-coupled receptors are one of the six major pharmacological targets into which the Guide is divided, with the others being: ion channels, nuclear hormone receptors, catalytic receptors, enzymes and transporters. These are presented with nomenclature guidance and summary information on the best available pharmacological tools, alongside key references and suggestions for further reading. The landscape format of the Concise Guide is designed to facilitate comparison of related targets from material contemporary to mid-2023, and supersedes data presented in the 2021/22, 2019/20, 2017/18, 2015/16 and 2013/14 Concise Guides and previous Guides to Receptors and Channels. It is produced in close conjunction with the Nomenclature and Standards Committee of the International Union of Basic and Clinical Pharmacology (NC-IUPHAR), therefore, providing official IUPHAR classification and nomenclature for human drug targets, where appropriate.
  •  
2.
  • Álvarez-Muñiz, Jaime, et al. (författare)
  • The Giant Radio Array for Neutrino Detection (GRAND) : Science and design
  • 2020
  • Ingår i: Science China Physics, Mechanics & Astronomy. - : Springer Science and Business Media LLC. - 1674-7348 .- 1869-1927. ; 63:1
  • Forskningsöversikt (refereegranskat)abstract
    • The Giant Radio Array for Neutrino Detection (GRAND) is a planned large-scale observatory of ultra-high-energy (UHE) cosmic particles, with energies exceeding 108 GeV. Its goal is to solve the long-standing mystery of the origin of UHE cosmic rays. To do this, GRAND will detect an unprecedented number of UHE cosmic rays and search for the undiscovered UHE neutrinos and gamma rays associated to them with unmatched sensitivity. GRAND will use large arrays of antennas to detect the radio emission coming from extensive air showers initiated by UHE particles in the atmosphere. Its design is modular: 20 separate, independent sub-arrays, each of 10000 radio antennas deployed over 10000 km(2). A staged construction plan will validate key detection techniques while achieving important science goals early. Here we present the science goals, detection strategy, preliminary design, performance goals, and construction plans for GRAND.
  •  
3.
  • Christopoulos, Arthur, et al. (författare)
  • THE CONCISE GUIDE TO PHARMACOLOGY 2021/22: G protein-coupled receptors.
  • 2021
  • Ingår i: British journal of pharmacology. - : Wiley. - 1476-5381 .- 0007-1188. ; 178 Suppl 1
  • Forskningsöversikt (refereegranskat)abstract
    • The Concise Guide to PHARMACOLOGY 2021/22 is the fifth in this series of biennial publications. The Concise Guide provides concise overviews, mostly in tabular format, of the key properties of nearly 1900 human drug targets with an emphasis on selective pharmacology (where available), plus links to the open access knowledgebase source of drug targets and their ligands (www.guidetopharmacology.org), which provides more detailed views of target and ligand properties. Although the Concise Guide constitutes over 500 pages, the material presented is substantially reduced compared to information and links presented on the website. It provides a permanent, citable, point-in-time record that will survive database updates. The full contents of this section can be found at http://onlinelibrary.wiley.com/doi/bph.15538. G protein-coupled receptors are one of the six major pharmacological targets into which the Guide is divided, with the others being: ion channels, nuclear hormone receptors, catalytic receptors, enzymes and transporters. These are presented with nomenclature guidance and summary information on the best available pharmacological tools, alongside key references and suggestions for further reading. The landscape format of the Concise Guide is designed to facilitate comparison of related targets from material contemporary to mid-2021, and supersedes data presented in the 2019/20, 2017/18, 2015/16 and 2013/14 Concise Guides and previous Guides to Receptors and Channels. It is produced in close conjunction with the Nomenclature and Standards Committee of the International Union of Basic and Clinical Pharmacology (NC-IUPHAR), therefore, providing official IUPHAR classification and nomenclature for human drug targets, where appropriate.
  •  
4.
  • Ammirati, Enrico, et al. (författare)
  • Outcome of patients on heart transplant list treated with a continuous-flow left ventricular assist device : Insights from the TRans-Atlantic registry on VAd and TrAnsplant (TRAViATA)
  • 2021
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273. ; 324
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Geographic variations in management and outcomes of individuals supported by continuous-flow left ventricular assist devices (CF-LVAD) between the United States (US) and Europe (EU) is largely unknown. Methods: We created a retrospective, multinational registry of 524 patients who received a CF-LVAD (either HVAD or Heartmate II) between January 2008 and April 2017. Follow up spanned from date of CF-LVAD implant to post-HTx period with a median follow up of 44.8 months. Results: The cohort included 299 (57.1%) EU and 225 (42.9%) US patients. Although the US cohort was significantly older with a higher prevalence of comorbidities, survival was similar between the cohorts (US 63.1%, EU 68.4% at 5 years, unadjusted log-rank test p = 0.43).Multivariate analyses suggested that older age, higher body mass index, elevated creatinine, use of temporary mechanical circulatory support prior CF-LVAD, and implantation of HVAD were associated with increased mortality. Among CF-LVAD patients undergoing HTx, the median time on CF-LVAD support was shorter in the US, meanwhile US donors were younger. Finally, the pattern of adverse events (stroke, gastrointestinal bleedings, late right ventricular failure, and driveline infection) during support differed significantly between US and EU. Conclusions: Although waitlisted patients in the US on CF-LVAD have higher risk comorbid conditions, the overall outcome is similar in US and EU. Geographic variations with regards to donor characteristics, duration of CF-LVAD support prior to transplant, and adverse events on support can explain the disparity in the utilization of mechanical bridge to transplant strategy between US and EU.
  •  
5.
  • Attié, David, et al. (författare)
  • A time projection chamber with GEM-based readout
  • 2017
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 856, s. 109-118
  • Tidskriftsartikel (refereegranskat)abstract
    • For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1. T solenoidal field and read out with three independent Gas Electron Multiplier (GEM) based readout modules, are reported. The TPC was exposed to a 6. GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
  •  
6.
  • Gasparovic, Hrvoje, et al. (författare)
  • Impact of progressive aortic regurgitation on outcomes after left ventricular assist device implantation
  • 2022
  • Ingår i: Heart and Vessels. - : Springer Science and Business Media LLC. - 0910-8327 .- 1615-2573. ; 37:12, s. 1985-1994
  • Tidskriftsartikel (refereegranskat)abstract
    • Aortic regurgitation (AR) following continuous flow left ventricular assist device implantation (cf-LVAD) may adversely impact outcomes. We aimed to assess the incidence and impact of progressive AR after cf-LVAD on prognosis, biomarkers, functional capacity and echocardiographic findings. In an analysis of the PCHF-VAD database encompassing 12 European heart failure centers, patients were dichotomized according to the progression of AR following LVAD implantation. Patients with de-novo AR or AR progression (AR_1) were compared to patients without worsening AR (AR_0). Among 396 patients (mean age 53 ± 12 years, 82% male), 153 (39%) experienced progression of AR over a median of 1.4 years on LVAD support. Before LVAD implantation, AR_1 patients were less frequently diabetic, had lower body mass indices and higher baseline NT-proBNP values. Progressive AR did not adversely impact mortality (26% in both groups, HR 0.91 [95% CI 0.61–1.36]; P = 0.65). No intergroup variability was observed in NT-proBNP values and 6-minute walk test results at index hospitalization discharge and at 6-month follow-up. However, AR_1 patients were more likely to remain in NYHA class III and had worse right ventricular function at 6-month follow-up. Lack of aortic valve opening was related to de-novo or worsening AR (P < 0.001), irrespective of systolic blood pressure (P = 0.67). Patients commonly experience de-novo or worsening AR when exposed to continuous flow of contemporary LVADs. While reducing effective forward flow, worsening AR did not influence survival. However, less complete functional recovery and worse RV performance among AR_1 patients were observed. Lack of aortic valve opening was associated with progressive AR.
  •  
7.
  • Jakus, Nina, et al. (författare)
  • Improved survival of left ventricular assist device carriers in Europe according to implantation eras : results from the PCHF-VAD registry
  • 2022
  • Ingår i: European Journal of Heart Failure. - : Wiley. - 1388-9842 .- 1879-0844. ; 24:7, s. 1305-1315
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Temporal changes in patient selection and major technological developments have occurred in the field of left ventricular assist devices (LVADs), yet analyses depicting this trend are lacking for Europe. We describe the advances of European LVAD programmes from the PCHF-VAD registry across device implantation eras. Methods and results: Of 583 patients from 13 European centres in the registry, 556 patients (mean age 53 ± 12 years, 82% male) were eligible for this analysis. Patients were divided into eras (E) by date of LVAD implantation: E1 from December 2006 to December 2012 (6 years), E2 from January 2013 to January 2020 (7 years). Patients implanted more recently were older with more comorbidities, but less acutely ill. Receiving an LVAD in E2 was associated with improved 1-year survival in adjusted analysis (hazard ratio [HR] 0.58, 95% confidence interval [CI] 0.35–0.98; p = 0.043). LVAD implantation in E2 was associated with a significantly lower chance of heart transplantation (adjusted HR 0.40, 95% CI 0.23–0.67; p = 0.001), and lower risk of LVAD-related infections (adjusted HR 0.64, 95% CI 0.43–0.95; p = 0.027), both in unadjusted and adjusted analyses. The adjusted risk of haemocompatibility-related events decreased (HR 0.60, 95% CI 0.39–0.91; p = 0.016), while heart failure-related events increased in E2 (HR 1.67, 95% CI 1.02–2.75; p = 0.043). Conclusion: In an analysis depicting the evolving landscape of continuous-flow LVAD carriers in Europe over 13 years, a trend towards better survival was seen in recent years, despite older recipients with more comorbidities, potentially attributable to increasing expertise of LVAD centres, improved patient selection and pump technology. However, a smaller chance of undergoing heart transplantation was noted in the second era, underscoring the relevance of improved outcomes on LVAD support.
  •  
8.
  • Radhoe, Sumant P., et al. (författare)
  • How does age affect outcomes after left ventricular assist device implantation : results from the PCHF-VAD registry
  • 2023
  • Ingår i: ESC Heart Failure. - : Wiley. - 2055-5822. ; 10:2, s. 884-894
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Use of left ventricular assist devices (LVADs) in older patients has increased, and assessing outcomes in older LVAD recipients is important. Therefore, this study aimed to investigate associations between age and outcomes after continuous-flow LVAD (cf-LVAD) implantation. Methods and results: Cf-LVAD patients from the multicentre European PCHF-VAD registry were included and categorized into those <50, 50–64, and ≥65 years old. The primary endpoint was all-cause mortality. Among secondary outcomes were heart failure (HF) hospitalizations, right ventricular (RV) failure, haemocompatibility score, bleeding events, non-fatal thromboembolic events, and device-related infections. Of 562 patients, 184 (32.7%) were <50, 305 (54.3%) were aged 50–64, whereas 73 (13.0%) were ≥65 years old. Median follow-up was 1.1 years. Patients in the oldest age group were significantly more often designated as destination therapy (DT) candidates (61%). A 10 year increase in age was associated with a significantly higher risk of mortality (hazard ratio [HR] 1.34, 95% confidence interval [CI] [1.15–1.57]), intracranial bleeding (HR 1.49, 95% CI [1.10–2.02]), and non-intracranial bleeding (HR 1.30, 95% CI [1.09–1.56]), which was confirmed by a higher mean haemocompatibility score (1.37 vs. 0.77, oldest vs. youngest groups, respectively, P = 0.033). Older patients suffered from less device-related infections requiring systemic antibiotics. No age-related differences were observed in HF-related hospitalizations, ventricular arrhythmias, pump thrombosis, non-fatal thromboembolic events, or RV failure. Conclusions: In the PCHF-VAD registry, higher age was associated with increased risk of mortality, and especially with increased risk of major bleeding, which is particularly relevant for the DT population. The risks of HF hospitalizations, pump thrombosis, ventricular arrhythmia, or RV failure were comparable. Strikingly, older patients had less device-related infections.
  •  
9.
  • Radhoe, Sumant P., et al. (författare)
  • Sex-related differences in left ventricular assist device utilization and outcomes : results from the PCHF-VAD registry
  • 2023
  • Ingår i: ESC Heart Failure. - : Wiley. - 2055-5822. ; 10:2, s. 1054-1065
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Data on sex and left ventricular assist device (LVAD) utilization and outcomes have been conflicting and mostly confined to US studies incorporating older devices. This study aimed to investigate sex-related differences in LVAD utilization and outcomes in a contemporary European LVAD cohort. Methods and results: This analysis is part of the multicentre PCHF-VAD registry studying continuous-flow LVAD patients. The primary outcome was all-cause mortality. Secondary outcomes included ventricular arrhythmias, right ventricular failure, bleeding, thromboembolism, and the haemocompatibility score. Multivariable Cox regression models were used to assess associations between sex and outcomes. Overall, 457 men (81%) and 105 women (19%) were analysed. At LVAD implant, women were more often in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1 or 2 (55% vs. 41%, P = 0.009) and more often required temporary mechanical circulatory support (39% vs. 23%, P = 0.001). Mean age was comparable (52.1 vs. 53.4 years, P = 0.33), and median follow-up duration was 344 [range 147–823] days for women and 435 [range 190–816] days for men (P = 0.40). No significant sex-related differences were found in all-cause mortality (hazard ratio [HR] 0.79 for female vs. male sex, 95% confidence interval [CI] [0.50–1.27]). Female LVAD patients had a lower risk of ventricular arrhythmias (HR 0.56, 95% CI [0.33–0.95]) but more often experienced right ventricular failure. No significant sex-related differences were found in other outcomes. Conclusions: In this contemporary European cohort of LVAD patients, far fewer women than men underwent LVAD implantation despite similar clinical outcomes. This is important as the proportion of female LVAD patients (19%) was lower than the proportion of females with advanced HF as reported in previous studies, suggesting underutilization. Also, female patients were remarkably more often in INTERMACS profile 1 or 2, suggesting later referral for LVAD therapy. Additional research in female patients is warranted.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy