SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Timsit Marc Olivier) "

Sökning: WFRF:(Timsit Marc Olivier)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gaillard, Francois, et al. (författare)
  • Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors
  • 2017
  • Ingår i: European Radiology. - : SPRINGER. - 0938-7994 .- 1432-1084. ; 27:2, s. 651-659
  • Tidskriftsartikel (refereegranskat)abstract
    • Screening of living kidney donors may require scintigraphy to split glomerular filtration rate (GFR). To determine the usefulness of computed tomography (CT) to split GFR, we compared scintigraphy-split GFR to CT-split GFR. We evaluated CT-split GFR as a screening test to detect scintigraphy-split GFR lower than 40 mL/min/1.73 m(2)/kidney. This was a monocentric retrospective study on 346 potential living donors who had GFR measurement, renal scintigraphy, and CT. We predicted GFR for each kidney by splitting GFR using the following formula: Volume-split GFR for a given kidney = measured GFR*[volume of this kidney/(volume of this kidney + volume of the opposite kidney)]. The same formula was used for length-split GFR. We compared length- and volume-split GFR to scintigraphy-split GFR at donation and with a 4-year follow-up. A better correlation was observed between length-split GFR and scintigraphy-split GFR (r = 0.92) than between volume-split GFR and scintigraphy-split GFR (r = 0.89). A length-split GFR threshold of 45 mL/min/1.73 m(2)/kidney had a sensitivity of 100 % and a specificity of 75 % to detect scintigraphy-split GFR less than 40 mL/min/1.73 m(2)/kidney. Both techniques with their respective thresholds detected living donors with similar eGFR evolution during follow-up. Length-split GFR can be used to detect patients requiring scintigraphy. aEuro cent Excellent correlation between kidney length and scintigraphy predicted GFR aEuro cent Kidney length screening detects all donors with GFR lower than 40 mL/min/1.73 m (2) aEuro cent Kidney length screening can replace scintigraphy screening.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy