SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Torild Petronella) "

Sökning: WFRF:(Torild Petronella)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Råmunddal, Truls, 1973, et al. (författare)
  • Safety and Feasibility Using a Fluid-Filled Wire to Avoid Hydrostatic Errors in Physiological Intracoronary Measurements.
  • 2024
  • Ingår i: Cardiology research and practice. - 2090-8016. ; 2024
  • Tidskriftsartikel (refereegranskat)abstract
    • Using a fluid-filled wire with a pressure sensor outside the patient compared to a conventional pressure wire may avoid the systematic error introduced by the hydrostatic pressure within the coronary circulation.To assess the safety and effectiveness of the novel fluid-filled wire, Wirecath (Cavis Technologies, Uppsala, Sweden), as well as its ability to avoid the hydrostatic pressure error.The Wirecath pressure wire was used in 45 eligible patients who underwent invasive coronary angiography and had a clinical indication for invasive coronary pressure measurement at Sahlgrenska University Hospital, Gothenburg, Sweden. In 29 patients, a simultaneous measurement was performed with a conventional coronary pressure wire (PressureWire X, Abbott Medical, Plymouth, MN, USA), and in 19 patients, the vertical height difference between the tip of the guide catheter and the wire measure point was measured in a 90-degree lateral angiographic projection. No adverse events caused by the pressure wires were reported. The mean Pd/Pa and mean FFR using the fluid-filled wire and the sensor-tipped wire differed significantly; however, after correcting for the hydrostatic effect, the sensor-tipped wire pressure correlated well with the fluid-filled wire pressure (R=0.74 vs. R=0.89 at rest and R=0.89 vs. R=0.98 at hyperemia).Hydrostatic errors in physiologic measurements can be avoided by using the fluid-filled Wirecath wire, which was safe to use in the present study. This trial is registered with NCT04776577 and NCT04802681.
  •  
2.
  • Sparv, David, et al. (författare)
  • The Analgesic Effect of Oxygen in Suspected Acute Myocardial Infarction : A Substudy of the DETO2X-AMI Trial
  • 2018
  • Ingår i: JACC: Cardiovascular Interventions. - : Elsevier BV. - 1936-8798 .- 1876-7605. ; 39, s. 546-546
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: In this substudy of the DETO2X-AMI (An Efficacy and Outcome Study of Supplemental Oxygen Treatment in Patients With Suspected Myocardial Infarction) trial, the authors aimed to assess the analgesic effect of moderate-flow oxygen supplementation in patients with suspected acute myocardial infarction (AMI) treated with percutaneous coronary intervention (PCI) and to study the effect of oxygen supplementation on the use of opiates and sedatives during PCI. Background: Routine oxygen in normoxemic patients with AMI does not provide clinical benefit. However, oxygen may relieve ischemic pain. Methods: Patients were randomly allocated to oxygen or ambient air according to the main study protocol. After PCI, peak level of pain during PCI was measured by the Visual Analogue Scale. The total amount of opiates and sedatives was reported. Results: A total of 622 patients were enrolled: 330 in the oxygen group and 292 in the ambient air group. There was no significant difference in peak level of pain (oxygen 4.0 [1.0 to 6.0] vs. air 3.0 [0.6 to 6.0]; p = 0.37), use of opiates (mg) (oxygen 0.0 [0.0 to 3.0] vs. air 0.0 [0.0 to 3.0]; p = 0.31), or use of sedatives between the groups (median [interquartile range]) (oxygen 2.5 [0.0 to 2.5] vs. air 2.5 [0.0 to 2.5]; p = 0.74). Conclusions: In the present study, the authors did not find any analgesic effect of routine oxygen as compared with ambient air, and no differences in the use of sedatives and opiates during PCI. Our results indicate that moderate-flow oxygen supplementation does not relieve pain in normoxemic patients with suspected AMI undergoing treatment with PCI and should thus not be used for this purpose.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy