SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Toshito T.) "

Sökning: WFRF:(Toshito T.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Toshito, T., et al. (författare)
  • Measurements of projectile-like Be-8 and B-9 production in 200-400 MeV/nucleon C-12 on water
  • 2008
  • Ingår i: Physical Review C - Nuclear Physics. - 2469-9985 .- 2469-9993. ; 78:6, s. 4-
  • Tidskriftsartikel (refereegranskat)abstract
    • We have studied the production of the projectile-like fragments Be-8 and B-9 produced in interactions of 200 to 400 MeV/nucleon carbon ions with water, using emulsion detectors. In this Brief Report we present the first published production cross section of the projectile-like fragment B-9 in the energy region above 100 MeV/nucleon. The measured production cross sections of these nuclides were compared to calculations using a semiempirical model. We found that the measured cross sections deviate from the calculated values by a factor up to about six. This information is of importance for benchmarking and improving heavy ion nuclear reaction models.
  •  
2.
  • Toshito, T., et al. (författare)
  • Measurements of total and partial charge-changing cross sections for 200-to 400-MeV/nucleon C-12 on water and polycarbonate
  • 2007
  • Ingår i: Physical Review C - Nuclear Physics. - 2469-9985 .- 2469-9993. ; 75:5, s. 8-
  • Tidskriftsartikel (refereegranskat)abstract
    • We have studied charged nuclear fragments produced by 200- to 400-MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements and model predictions. This study is of importance for validating and improving carbon-ion therapy treatment planning systems and for estimating the radiological risks for personnel on space missions, because carbon is a significant component of galactic cosmic rays.
  •  
3.
  • Arce, P., et al. (författare)
  • Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
  • 2021
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 48:1, s. 19-56
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. Aims: To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. Materials and Methods: G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. Results: This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. Discussion: Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. Conclusion: The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy