SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Turin P.) "

Sökning: WFRF:(Turin P.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Maksimovic, M., et al. (författare)
  • First observations and performance of the RPW instrument on board the Solar Orbiter mission
  • 2021
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 656
  • Tidskriftsartikel (refereegranskat)abstract
    • The Radio and Plasma Waves (RPW) instrument on the ESA Solar Orbiter mission is designed to measure in situ magnetic and electric fields and waves from the continuum up to several hundred kHz. The RPW also observes solar and heliospheric radio emissions up to 16 MHz. It was switched on and its antennae were successfully deployed two days after the launch of Solar Orbiter on February 10, 2020. Since then, the instrument has acquired enough data to make it possible to assess its performance and the electromagnetic disturbances it experiences. In this article, we assess its scientific performance and present the first RPW observations. In particular, we focus on a statistical analysis of the first observations of interplanetary dust by the instrument's Thermal Noise Receiver. We also review the electro-magnetic disturbances that RPW suffers, especially those which potential users of the instrument data should be aware of before starting their research work.
  •  
2.
  • Maksimovic, M., et al. (författare)
  • The Solar Orbiter Radio and Plasma Waves (RPW) instrument
  • 2020
  • Ingår i: Astronomy and Astrophysics. - : EDP SCIENCES S A. - 0004-6361 .- 1432-0746. ; 642
  • Tidskriftsartikel (refereegranskat)abstract
    • The Radio and Plasma Waves (RPW) instrument on the ESA Solar Orbiter mission is described in this paper. This instrument is designed to measure in-situ magnetic and electric fields and waves from the continuous to a few hundreds of kHz. RPW will also observe solar radio emissions up to 16 MHz. The RPW instrument is of primary importance to the Solar Orbiter mission and science requirements since it is essential to answer three of the four mission overarching science objectives. In addition RPW will exchange on-board data with the other in-situ instruments in order to process algorithms for interplanetary shocks and type III langmuir waves detections.
  •  
3.
  • Fortier, A., et al. (författare)
  • CHEOPS in-flight performance: A comprehensive look at the first 3.5 yr of operations
  • 2024
  • Ingår i: Astronomy and Astrophysics. - 0004-6361 .- 1432-0746. ; 687
  • Tidskriftsartikel (refereegranskat)abstract
    • Context. Since the discovery of the first exoplanet almost three decades ago, the number of known exoplanets has increased dramatically. By beginning of the 2000s it was clear that dedicated facilities to advance our studies in this field were needed. The CHaracterising ExOPlanet Satellite (CHEOPS) is a space telescope specifically designed to monitor transiting exoplanets orbiting bright stars. In September 2023, CHEOPS completed its nominal mission duration of 3.5 yr and remains in excellent operational conditions. As a testament to this, the mission has been extended until the end of 2026. Aims. Scientific and instrumental data have been collected throughout in-orbit commissioning and nominal operations, enabling a comprehensive analysis of the missiona's performance. In this article, we present the results of this analysis with a twofold goal. First, we aim to inform the scientific community about the present status of the mission and what can be expected as the instrument ages. Secondly, we intend for this publication to serve as a legacy document for future missions, providing insights and lessons learned from the successful operation of CHEOPS. Methods. To evaluate the instrument performance in flight, we developed a comprehensive monitoring and characterisation (M&C) programme. It consists of dedicated observations that allow us to characterise the instrumenta's response and continuously monitor its behaviour. In addition to the standard collection of nominal science and housekeeping data, these observations provide valuable input for detecting, modelling, and correcting instrument systematics, discovering and addressing anomalies, and comparing the instrumenta's actual performance with expectations. Results. The precision of the CHEOPS measurements has enabled the mission objectives to be met and exceeded. The satellitea's performance remains stable and reliable, ensuring accurate data collection throughout its operational life. Careful modelling of the instrumental systematics allows the data quality to be significantly improved during the light curve analysis phase, resulting in more precise scientific measurements. Conclusions. CHEOPS is compliant with the driving scientific requirements of the mission. Although visible, the ageing of the instrument has not affected the missiona's performance. The satellitea's capabilities remain robust, and we are confident that we will continue to acquire high-quality data during the mission extension.
  •  
4.
  • Bale, S. D., et al. (författare)
  • The FIELDS Instrument Suite for Solar Probe Plus
  • 2016
  • Ingår i: Space Science Reviews. - : Springer Science and Business Media LLC. - 0038-6308 .- 1572-9672. ; 204:1-4, s. 49-82
  • Forskningsöversikt (refereegranskat)abstract
    • NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
  •  
5.
  • Coresh, Josef, et al. (författare)
  • Decline in estimated glomerular filtration rate and subsequent risk of end-stage renal disease and mortality
  • 2014
  • Ingår i: Journal of the American Medical Association (JAMA). - : American Medical Association (AMA). - 0098-7484 .- 1538-3598. ; 311:24, s. 2518-2531
  • Tidskriftsartikel (refereegranskat)abstract
    • IMPORTANCE: The established chronic kidney disease (CKD) progression end point of end-stage renal disease (ESRD) or a doubling of serum creatinine concentration (corresponding to a change in estimated glomerular filtration rate [GFR] of −57% or greater) is a late event.OBJECTIVE: To characterize the association of decline in estimated GFR with subsequent progression to ESRD with implications for using lesser declines in estimated GFR as potential alternative end points for CKD progression. Because most people with CKD die before reaching ESRD, mortality risk also was investigated.DATA SOURCES AND STUDY SELECTION: Individual meta-analysis of 1.7 million participants with 12,344 ESRD events and 223,944 deaths from 35 cohorts in the CKD Prognosis Consortium with a repeated measure of serum creatinine concentration over 1 to 3 years and outcome data.DATA EXTRACTION AND SYNTHESIS: Transfer of individual participant data or standardized analysis of outputs for random-effects meta-analysis conducted between July 2012 and September 2013, with baseline estimated GFR values collected from 1975 through 2012.MAIN OUTCOMES AND MEASURES: End-stage renal disease (initiation of dialysis or transplantation) or all-cause mortality risk related to percentage change in estimated GFR over 2 years, adjusted for potential confounders and first estimated GFR.RESULTS: The adjusted hazard ratios (HRs) of ESRD and mortality were higher with larger estimated GFR decline. Among participants with baseline estimated GFR of less than 60 mL/min/1.73 m2, the adjusted HRs for ESRD were 32.1 (95% CI, 22.3-46.3) for changes of −57% in estimated GFR and 5.4 (95% CI, 4.5-6.4) for changes of −30%. However, changes of −30% or greater (6.9% [95% CI, 6.4%-7.4%] of the entire consortium) were more common than changes of −57% (0.79% [95% CI, 0.52%-1.06%]). This association was strong and consistent across the length of the baseline period (1 to 3 years), baseline estimated GFR, age, diabetes status, or albuminuria. Average adjusted 10-year risk of ESRD (in patients with a baseline estimated GFR of 35 mL/min/1.73 m2) was 99% (95% CI, 95%-100%) for estimated GFR change of −57%, was 83% (95% CI, 71%-93%) for estimated GFR change of −40%, and was 64% (95% CI, 52%-77%) for estimated GFR change of −30% vs 18% (95% CI, 15%-22%) for estimated GFR change of 0%. Corresponding mortality risks were 77% (95% CI, 71%-82%), 60% (95% CI, 56%-63%), and 50% (95% CI, 47%-52%) vs 32% (95% CI, 31%-33%), showing a similar but weaker pattern.CONCLUSIONS AND RELEVANCE: Declines in estimated GFR smaller than a doubling of serum creatinine concentration occurred more commonly and were strongly and consistently associated with the risk of ESRD and mortality, supporting consideration of lesser declines in estimated GFR (such as a 30% reduction over 2 years) as an alternative end point for CKD progression.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy