SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ullschmied U.) "

Sökning: WFRF:(Ullschmied U.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Torrisi, Lorenzo, et al. (författare)
  • High intensity laser-generating plasmas in forward direction in thin films and Thomson parabola spectrometer monitorage
  • 2010
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Asterix laser at PALS Laboratory of Prague, operating at 1315 nm fundamental wavelength, 300 ps pulse duration, 1016 W/cm2 intensity and single pulse mode, was employed to irradiate thin hydrogenated targets placed in high vacuum. Non-equilibrium plasmas were obtained in forward direction, i.e. along the normal to the target surface on the rear of the irradiated thin films. Plasmas were monitored with different ion detectors, placed around the direction normal to the target. The main detector was a Thomson parabola spectrometer aligned along the normal in forward direction. This spectrometer permits to provide many plasma parameters concerning the involved ions (energy, charge state, mass,...) obtained in a single laser shot. The spectrometer images, obtained by using a MCP coupled to a fast CCD camera, can be processed by a comparison with the simulation data obtained by a proper software. High ion energies and charge states have been obtained as a function of the laser parameters, target thickness and composition and irradiation conditions.
  •  
2.
  • Torrisi, Lorenzo, et al. (författare)
  • Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas
  • 2009
  • Ingår i: Journal of Applied Physics. - : American Institute of Physics (AIP). - 0021-8979 .- 1089-7550. ; 105, s. 123304-1-123304-7
  • Tidskriftsartikel (refereegranskat)abstract
    • A single-crystal silicon carbide SiC detector was used for measurements of soft x rays, electrons, and ion emission from laser-generated plasma obtained with the use of the Prague Asterix Laser System PALS at intensities of the order of 1016 W/cm2 and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the nature of the irradiated target. The spectra obtained by using the SiC detector show not only the photopeak due to UV and softx-ray detection, but also various peaks due to the detection of energetic charged particles. Time-of-flight technique was employed to determine the ion kinetic energy of particles emitted from the plasma and to perform a comparison between SiC and traditional ion collectors. The detector was also employed by inserting absorber films of different thickness in front of the SiC surface inorder to determine, as a first approximation, the mean energy of the soft x-ray emission from the plasma.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy