1.
  • Alisic, S., et al. (författare)
  • Final report on EURAMET comparison on 1 kg stainless steel mass standards
  • 2020
  • Ingår i: Metrologia. - : Institute of Physics Publishing. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to demonstrate the equivalence in calibration of mass standards among National Metrology Institutes (NMIs) of EURAMET this key comparison (KC) on 1 kg stainless steel mass standards has been carried out under the auspices of EURAMET. The comparison was undertaken with reference to the International Prototype Kilogram (IPK) as the definition of the unit of mass. The overall result shows good consistency among the participants. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
2.
  • Altlntaş, A., et al. (författare)
  • Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure
  • 2020
  • Ingår i: Metrologia. - : Institute of Physics Publishing. - 0026-1394 .- 1681-7575. ; 57:1
  • Tidskriftsartikel (refereegranskat)abstract
    • A EURAMET key comparison of the national pressure standards in the range 0.7 MPa to 7.0 MPa of gas gauge pressure was carried out. The circulation of the transfer standard began in November 2011 and lasted until November 2016. The measurand of the comparison was the effective area of the piston-cylinder assembly determined by gauge pressure measurements in the range from 0.7 MPa to 7.0 MPa. As the comparison reference value, the weighted mean of the results of the laboratories with primary pressure standards was used. With this reference value, all the participants who delivered the results demonstrated equivalence respective to the reference value within expanded uncertainties (k = 2) on all the range. The results of this comparison were linked to CCM key comparison CCM.P-K1.c. Also in relation to the reference values of CCM.P-K1.c, all participants demonstrated agreement within expanded uncertainties (k = 2) at all pressure points.
  •  