SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vader J P) "

Sökning: WFRF:(Vader J P)

  • Resultat 1-10 av 17
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Froehlich, F, et al. (författare)
  • EPAGE Study Group. Current sedation and monitoring practice for colonoscopy: an international observational study (EPAGE)
  • 2006
  • Ingår i: Endoscopy. - : Georg Thieme Verlag KG. - 1438-8812 .- 0013-726X. ; 38:5, s. 461-469
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Study Aims: Sedation and monitoring practice during colonoscopy varies between centers and over time. Knowledge of current practice is needed to ensure quality of care and help focus future research. The objective of this study was to examine sedation and monitoring practice in endoscopy centers internationally. Patients and Methods: This observational study included consecutive patients referred for colonoscopy at 21 centers in 11 countries. Endoscopists reported sedation and monitoring practice, using a standard questionnaire for each patient. Results: 6004 patients were included in this study, of whom 53 % received conscious/moderate sedation during colonoscopy, 30 % received deep sedation, and 17 % received no sedation. Sedation agents most commonly used were midazolam (47 %) and opioids (33 %). Pulse oximetry was done during colonoscopy in 77 % of patients, blood pressure monitoring in 34 %, and electrocardiography in 24 %. Pulse oximetry was most commonly used for moderately sedated patients, while blood pressure monitoring and electrocardiography were used predominantly for deeply sedated patients. Sedation and monitoring use ranged from 0 % to 100 % between centers. Oxygen desaturation (≤ 85 %) occurred in 5 % of patients, of whom 80 % were moderately sedated. On average, three staff members were involved in procedures. An anesthesiologist was present during 27 % of colonoscopies, and during 85 % of colonoscopies using deep sedation. Conclusions: Internationally, sedation and monitoring practice during colonoscopy varied widely. Moderate sedation was the most common sedation method used and electronic monitoring was used in three-quarters of patients. Deep sedation tended to be more resource-intensive, implying a greater use of staff and monitoring.
  •  
3.
  • Nordin, Joel Z., et al. (författare)
  • Ultrafiltration with size-exclusion liquid chromatography for high yield isolation of extracellular vesicles preserving intact biophysical and functional properties
  • 2015
  • Ingår i: Nanomedicine. - : Elsevier BV. - 1549-9634 .- 1549-9642. ; 11:4, s. 879-883
  • Tidskriftsartikel (refereegranskat)abstract
    • Extracellular vesicles (EVs) are natural nanoparticles that mediate intercellular transfer of RNA and proteins and are of great medical interest; serving as novel biomarkers and potential therapeutic agents. However, there is little consensus on the most appropriate method to isolate high-yield and high-purity EVs from various biological fluids. Here, we describe a systematic comparison between two protocols for EV purification: ultrafiltration with subsequent liquid chromatography (UF-LC) and differential ultracentrifugation (UC). A significantly higher EV yield resulted from UF-LC as compared to UC, without affecting vesicle protein composition. Importantly, we provide novel evidence that, in contrast to UC-purified EVs, the biophysical properties of UF-LC-purified EVs are preserved, leading toadifferent in vivo biodistribution, with less accumulation in lungs. Finally, we show that UF-LC is scalable and adaptable for EV isolation from complex media types such as stem cell media, which is of huge significance for future clinical applications involving EVs.
  •  
4.
  • Harris, JK, et al. (författare)
  • Factors associated with the technical performance of colonoscopy: An EPAGE study.
  • 2007
  • Ingår i: Digestive and Liver Disease. - : Elsevier BV. - 1590-8658. ; 39:7, s. 678-689
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Variations in colonoscopy practice exist, which may be related to healthcare quality. Aims To determine factors associated with three performance indicators of colonoscopy: complete colonoscopy, adenomatous polyp diagnosis, and duration. Patients Consecutive patients referred for colonoscopy from 21 centres in 11 countries. Methods This prospective observational study used multiple variable regression analyses to identify determinants of the quality indicators. Results Six thousand and four patients were included in the study. Patients from private, open-access centres (odds ratio: 3.17, 95% confidence interval: 1.87–5.38) were more likely to have a complete colonoscopy than patients from public, gatekeeper centres. Patients from centres where over 50% of the endoscopists were of senior rank were roughly twice as likely to have an adenoma diagnosed, and longer average withdrawal duration (odds ratio: 1.08, 95% confidence interval: 1.07–1.09) was associated with more frequent adenoma diagnoses. Patients who had difficulty during colonoscopy had longer durations to caecum (time ratio: 2.87, 95% confidence interval: 2.72–3.01) and withdrawal durations (time ratio: 1.26, 95% confidence interval: 1.18–1.33) than patients who had no difficulties. Conclusions Multiple factors have been identified as being associated with key quality indicators. The non-modifiable factors permit the identification of patients who may be at greater risk of not having quality colonoscopy, while changes to the modifiable factors may help improve the quality of colonoscopy.
  •  
5.
  •  
6.
  • Aoki, Y, et al. (författare)
  • Corrigendum
  • 2018
  • Ingår i: Brain : a journal of neurology. - : Oxford University Press (OUP). - 1460-2156. ; 141:5, s. e42-
  • Tidskriftsartikel (refereegranskat)
  •  
7.
  • de Jong, OG, et al. (författare)
  • A CRISPR-Cas9-based reporter system for single-cell detection of extracellular vesicle-mediated functional transfer of RNA
  • 2020
  • Ingår i: Nature communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 11:1, s. 1113-
  • Tidskriftsartikel (refereegranskat)abstract
    • Extracellular vesicles (EVs) form an endogenous transport system for intercellular transfer of biological cargo, including RNA, that plays a pivotal role in physiological and pathological processes. Unfortunately, whereas biological effects of EV-mediated RNA transfer are abundantly studied, regulatory pathways and mechanisms remain poorly defined due to a lack of suitable readout systems. Here, we describe a highly-sensitive CRISPR-Cas9-based reporter system that allows direct functional study of EV-mediated transfer of small non-coding RNA molecules at single-cell resolution. Using this CRISPR operated stoplight system for functional intercellular RNA exchange (CROSS-FIRE) we uncover various genes involved in EV subtype biogenesis that play a regulatory role in RNA transfer. Moreover we identify multiple genes involved in endocytosis and intracellular membrane trafficking that strongly regulate EV-mediated functional RNA delivery. Altogether, this approach allows the elucidation of regulatory mechanisms in EV-mediated RNA transfer at the level of EV biogenesis, endocytosis, intracellular trafficking, and RNA delivery.
  •  
8.
  •  
9.
  •  
10.
  • Sork, Helena, et al. (författare)
  • Lipid-based Transfection Reagents Exhibit Cryo-induced Increase in Transfection Efficiency
  • 2016
  • Ingår i: Molecular Therapy Nucleic Acids. - : Elsevier BV. - 2162-2531. ; 5
  • Tidskriftsartikel (refereegranskat)abstract
    • The advantages of lipid-based transfection reagents have permitted their widespread use in molecular biology and gene therapy. This study outlines the effect of cryo-manipulation of a cationic lipid-based formulation, Lipofectamine 2000, which, after being frozen and thawed, showed orders of magnitude higher plasmid delivery efficiency throughout eight different cell lines, without compromising cell viability. Increased transfection efficiency with the freeze-thawed reagent was also seen with 2'-O-methyl phosphorothioate oligonucleotide delivery and in a splice-correction assay. Most importantly, a log-scale improvement in gene delivery using the freeze-thawed reagent was seen in vivo. Using three different methods, we detected considerable differences in the polydispersity of the different nucleic acid complexes as well as observed a clear difference in their surface spreading and sedimentation, with the freeze-thawed ones displaying substantially higher rate of dispersion and deposition on the glass surface. This hitherto overlooked elevated potency of the freeze-thawed reagent facilitates the targeting of hard-to-transfect cells, accomplishes higher transfection rates, and decreases the overall amount of reagent needed for delivery. Additionally, as we also saw a slight increase in plasmid delivery using other freeze-thawed transfection reagents, we postulate that freeze-thawing might prove to be useful for an even wider variety of transfection reagents.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 17

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy