SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Van Belle S) "

Sökning: WFRF:(Van Belle S)

  • Resultat 1-10 av 25
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Van Holsbeke, C., et al. (författare)
  • Prospective external validation of the 'ovarian crescent sign' as a single ultrasound parameter to distinguish between benign and malignant adnexal pathology
  • 2010
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 36:1, s. 81-87
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To determine the sensitivity and specificity of the 'ovarian crescent sign' (OCS) - a rim of normal ovarian tissue seen adjacent to an ipsilateral adnexal mass as a sonographic feature to discriminate between benign and malignant adnexal masses. Methods The patients included were a subgroup of patients participating in the International Ovarian Tumor Analysis (IOTA) Phase 2 study, which is an international multicenter study. The subgroup comprised 1938 patients, with an adnexal mass, recruited from 19 ultrasound centers in different countries. All patients were scanned using the same standardized ultrasound protocol. Information on more than 40 demographic and ultrasound variables were collected, but the evaluation of the OCS was optional. Only patients from centers that had evaluated the OCS in >= 90% of their cases were included. The gold standard was the histological diagnosis of the adnexal mass. The ability of the OCS to discriminate between borderline or invasively malignant vs. benign adnexal masses, as well as between invasively malignant vs. other (benign and borderline) tumors, was determined and compared with the performance of subjective evaluation of ultrasound findings by the ultrasound examiner. Results The OCS was evaluated in 1377 adnexal masses from 12 centers, 938 (68%) masses being benign, 86 (6%) borderline, 305 (22%) primary invasive and 48 (3%) metastases. The OCS was present in 398 (42%) of 938 benign masses, in 14 (16%) of 86 borderline tumors, in 18 (6%) of 305 primary invasive tumors (one malignant struma ovarii, one uterine clear cell adenocarcinoma and 16 epithelial carcinomas, i.e. four Stage I and 12 Stage II-IV) and in two (4%) of 48 ovarian metastases. Hence, the sensitivity and specificity for absent OCS to identify a malignancy was 92% and 42%, respectively, and the positive and negative likelihood ratios (LR+ and LR-, respectively) were 1.60 and 0.18. Subjective impression performed significantly better than the OCS. Sensitivity and specificity were 90% and 92%, respectively, LR+ was 11.0 and LR- was 0.10. For discrimination between invasive vs. benign or borderline tumors, the sensitivity for absent OCS was 94%, the specificity was 40%, the LR+ was 1.58 and the LR- was 0.14. Conclusion This study confirms previous reports that the presence of the OCS decreases the likelihood of invasive malignancy in adnexal masses. However it is a poor discriminator between benign and malignant adnexal masses. Copyright (C) 2010 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
7.
  • Escaned, Javier, et al. (författare)
  • Safety of the Deferral of Coronary Revascularization on the Basis of Instantaneous Wave-Free Ratio and Fractional Flow Reserve Measurements in Stable Coronary Artery Disease and Acute Coronary Syndromes
  • 2018
  • Ingår i: JACC. - : Elsevier. - 1936-8798 .- 1876-7605. ; 11:15, s. 1437-1449
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES The aim of this study was to investigate the clinical outcomes of patients deferred from coronary revascularization on the basis of instantaneous wave-free ratio (iFR) or fractional flow reserve (FFR) measurements in stable angina pectoris (SAP) and acute coronary syndromes (ACS). BACKGROUND Assessment of coronary stenosis severity with pressure guidewires is recommended to determine the need for myocardial revascularization. METHODS The safety of deferral of coronary revascularization in the pooled per-protocol population (n = 4,486) of the DEFINE-FLAIR (Functional Lesion Assessment of Intermediate Stenosis to Guide Revascularisation) and iFR-SWEDEHEART (Instantaneous Wave-Free Ratio Versus Fractional Flow Reserve in Patients With Stable Angina Pectoris or Acute Coronary Syndrome) randomized clinical trials was investigated. Patients were stratified according to revascularization decision making on the basis of iFR or FFR and to clinical presentation (SAP or ACS). The primary endpoint was major adverse cardiac events (MACE), defined as the composite of all-cause death, nonfatal myocardial infarction, or unplanned revascularization at 1 year. RESULTS Coronary revascularization was deferred in 2,130 patients. Deferral was performed in 1,117 patients (50%) in the iFR group and 1,013 patients (45%) in the FFR group (p < 0.01). At 1 year, the MACE rate in the deferred population was similar between the iFR and FFR groups (4.12% vs. 4.05%; fully adjusted hazard ratio: 1.13; 95% confidence interval: 0.72 to 1.79; p = 0.60). A clinical presentation with ACS was associated with a higher MACE rate compared with SAP in deferred patients (5.91% vs. 3.64% in ACS and SAP, respectively; fully adjusted hazard ratio: 0.61 in favor of SAP; 95% confidence interval: 0.38 to 0.99; p = 0.04). CONCLUSIONS Overall, deferral of revascularization is equally safe with both iFR and FFR, with a low MACE rate of about 4%. Lesions were more frequently deferred when iFR was used to assess physiological significance. In deferred patients presenting with ACS, the event rate was significantly increased compared with SAP at 1 year. (C) 2018 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
  •  
8.
  •  
9.
  • Van Holsbeke, C., et al. (författare)
  • Acoustic streaming cannot discriminate reliably between endometriomas and other types of adnexal lesion: a multicenter study of 633 adnexal masses
  • 2010
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 35:3, s. 349-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To determine the ability of acoustic streaming to discriminate between endometriomas and other adnexal masses. Methods We used data from 1938 patients with an adnexal mass included in Phase 2 of the International Ovarian Tumor Analysis (IOTA) study. All patients had been examined by transvaginal gray-scale and Doppler ultrasound following a standardized research protocol. Assessment of acoustic streaming was voluntary and was carried out only in lesions containing echogenic cyst fluid. Acoustic streaming was defined as movement of particles inside the cyst fluid during gray-scale and/or color Doppler examination provided that the probe had been held still for two seconds to ensure that the movement of the particles was not caused by movement of the probe or the patient. Only centers where acoustic streaming had been evaluated in > 90% of cases were included. Sensitivity, specificity, positive and negative likelihood ratios (LR+, LR-), and positive and negative predictive values (PPV and NPV) of acoustic streaming with regard to endometrioma were calculated. Results 460 (24%) masses were excluded because they were examined in centers where <= 90% of the masses with echogenic cyst fluid had been evaluated for the presence of acoustic streaming. Acoustic streaming was evaluated in 633 of 646 lesions containing echogenic cyst fluid. It was present in 19 (9%) of 209 endometriomas and in 55 (13%) of 424 other lesions. This corresponds to a sensitivity of absent acoustic streaming with regard to endometrioma of 91% (190/209), a specificity of 13% (55/424), LR+ of 1.04, LR- of 0.69, PPV of 34% (190/559) and NPV of 74% (55/74). Conclusions Acoustic streaming cannot discriminate reliably between endometrioinas and other adnexal lesions, and the presence of acoustic streaming does not exclude an endometrioma. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
10.
  • Boyajian, T., et al. (författare)
  • Stellar diameters and temperatures - VI. High angular resolution measurements of the transiting exoplanet host stars HD 189733 and HD 209458 and implications for models of cool dwarfs
  • 2015
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : Oxford University Press (OUP). - 0035-8711 .- 1365-2966. ; 447:1, s. 846-857
  • Tidskriftsartikel (refereegranskat)abstract
    • We present direct radii measurements of the well-known transiting exoplanet host stars HD 189733 and HD 209458 using the CHARA Array interferometer. We find the limb-darkened angular diameters to be thetaLD = 0.3848 +/- 0.0055 and 0.2254 +/- 0.0072 milliarcsec for HD 189733 and HD 209458, respectively. HD 189733 and HD 209458 are currently the only two transiting exoplanet systems where detection of the respective planetary companion's orbital motion from high resolution spectroscopy has revealed absolute masses for both star and planet. We use our new measurements together with the orbital information from radial velocity and photometric time series data, Hipparcos distances, and newly measured bolometric fluxes to determine the stellar effective temperatures (Teff = 4875 +/- 43, 6093 +/- 103 K), stellar linear radii (R* = 0.805 +/- 0.016, 1.203 +/- 0.061 Rsun), mean stellar densities (rho* = 1.62 +/- 0.11, 0.58 +/- 0.14 rhosun), planetary radii (Rp = 1.216 +/- 0.024, 1.451 +/- 0.074 RJup), and mean planetary densities (rhop = 0.605 +/- 0.029, 0.196 +/- 0.033 rhoJup) for HD 189733 b and HD 209458 b, respectively. The stellar parameters for HD 209458, a F9 dwarf, are consistent with indirect estimates derived from spectroscopic and evolutionary modeling. However, we find that models are unable to reproduce the observational results for the K2 dwarf, HD 189733. We show that, for stellar evolutionary models to match the observed stellar properties of HD 189733, adjustments lowering the solar-calibrated mixing length parameter from 1.83 to 1.34 need to be employed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 25

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy