SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Van Belle V.) "

Sökning: WFRF:(Van Belle V.)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Demenais, F, et al. (författare)
  • Association of MC1R Variants and Host Phenotypes With Melanoma Risk in CDKN2A Mutation Carriers: A GenoMEL Study.
  • 2010
  • Ingår i: Journal of the National Cancer Institute. - : Oxford University Press (OUP). - 1460-2105 .- 0027-8874. ; 102, s. 1568-1583
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Carrying the cyclin-dependent kinase inhibitor 2A (CDKN2A) germline mutations is associated with a high risk for melanoma. Penetrance of CDKN2A mutations is modified by pigmentation characteristics, nevus phenotypes, and some variants of the melanocortin-1 receptor gene (MC1R), which is known to have a role in the pigmentation process. However, investigation of the associations of both MC1R variants and host phenotypes with melanoma risk has been limited. Methods We included 815 CDKN2A mutation carriers (473 affected, and 342 unaffected, with melanoma) from 186 families from 15 centers in Europe, North America, and Australia who participated in the Melanoma Genetics Consortium. In this family-based study, we assessed the associations of the four most frequent MC1R variants (V60L, V92M, R151C, and R160W) and the number of variants (1, ≥2 variants), alone or jointly with the host phenotypes (hair color, propensity to sunburn, and number of nevi), with melanoma risk in CDKN2A mutation carriers. These associations were estimated and tested using generalized estimating equations. All statistical tests were two-sided. Results Carrying any one of the four most frequent MC1R variants (V60L, V92M, R151C, R160W) in CDKN2A mutation carriers was associated with a statistically significantly increased risk for melanoma across all continents (1.24 × 10(-6) ≤ P ≤ .0007). A consistent pattern of increase in melanoma risk was also associated with increase in number of MC1R variants. The risk of melanoma associated with at least two MC1R variants was 2.6-fold higher than the risk associated with only one variant (odds ratio = 5.83 [95% confidence interval = 3.60 to 9.46] vs 2.25 [95% confidence interval = 1.44 to 3.52]; P(trend) = 1.86 × 10(-8)). The joint analysis of MC1R variants and host phenotypes showed statistically significant associations of melanoma risk, together with MC1R variants (.0001 ≤ P ≤ .04), hair color (.006 ≤ P ≤ .06), and number of nevi (6.9 × 10(-6) ≤ P ≤ .02). Conclusion Results show that MC1R variants, hair color, and number of nevi were jointly associated with melanoma risk in CDKN2A mutation carriers. This joint association may have important consequences for risk assessments in familial settings.
  •  
5.
  •  
6.
  • Testa, A. C., et al. (författare)
  • Intravenous contrast ultrasound examination using contrast-tuned imaging (CnTI (TM)) and the contrast medium SonoVue (R) for discrimination between benign and malignant adnexal masses with solid components
  • 2009
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 34:6, s. 699-710
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To determine whether intravenous contrast ultrasound examination is superior to gray-scale or power Doppler ultrasound for discrimination between benign and malignant adnexal masses with complex ultrasound morphology. Methods In an international multicenter study, 134 patients with an ovarian mass with solid components or a multilocular cyst with more than 10 cyst locules, underwent a standardized transvaginal ultrasound examination followed by contrast examination using the contrast-tuned imaging technique and intravenous injection of the contrast medium SonoVue (R). Time intensity curves were constructed, and peak intensity, area under the intensity curve, time to peak, sharpness and half wash-out time were calculated. The sensitivity and specificity with regard to malignancy were calculated and receiver-operating characteristics (ROC) curves were drawn for gray-scale, power Doppler and contrast variables and for pattern recognition (subjective assignment of a certainly benign, probably benign, uncertain or malignant diagnosis, using gray-scale and power Doppler ultrasound findings). The gold standard was the histological diagnosis of the surgically removed tumors. Results After exclusions (surgical removal of the mass > 3 months after the ultrasound examination, technical problems), 72 adnexal masses with solid components were used in our statistical analyses. The values for peak contrast signal intensity and area under the contrast signal intensity curve in malignant tumors were significantly higher than those in borderline tumors and benign tumors, while those for the benign and borderline tumors were similar. The area under the ROC curve of the best contrast variable with regard to diagnosing borderline or invasive malignancy (0.84) was larger than that of the best gray-scale (0.75) and power Doppler ultrasound variable (0.79) but smaller than that of pattern recognition (0.93). Conclusion Findings on ultrasound contrast examination differed between benign and malignant tumors but there was a substantial overlap in contrast findings between benign and borderline tumors. It appears that ultrasound contrast examination is not superior to conventional ultrasound techniques, which also have difficulty in distinguishing between benign and borderline tumors, but can easily differentiate invasive malignancies from other tumors. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
7.
  • Van Holsbeke, C., et al. (författare)
  • Acoustic streaming cannot discriminate reliably between endometriomas and other types of adnexal lesion: a multicenter study of 633 adnexal masses
  • 2010
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 35:3, s. 349-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To determine the ability of acoustic streaming to discriminate between endometriomas and other adnexal masses. Methods We used data from 1938 patients with an adnexal mass included in Phase 2 of the International Ovarian Tumor Analysis (IOTA) study. All patients had been examined by transvaginal gray-scale and Doppler ultrasound following a standardized research protocol. Assessment of acoustic streaming was voluntary and was carried out only in lesions containing echogenic cyst fluid. Acoustic streaming was defined as movement of particles inside the cyst fluid during gray-scale and/or color Doppler examination provided that the probe had been held still for two seconds to ensure that the movement of the particles was not caused by movement of the probe or the patient. Only centers where acoustic streaming had been evaluated in > 90% of cases were included. Sensitivity, specificity, positive and negative likelihood ratios (LR+, LR-), and positive and negative predictive values (PPV and NPV) of acoustic streaming with regard to endometrioma were calculated. Results 460 (24%) masses were excluded because they were examined in centers where <= 90% of the masses with echogenic cyst fluid had been evaluated for the presence of acoustic streaming. Acoustic streaming was evaluated in 633 of 646 lesions containing echogenic cyst fluid. It was present in 19 (9%) of 209 endometriomas and in 55 (13%) of 424 other lesions. This corresponds to a sensitivity of absent acoustic streaming with regard to endometrioma of 91% (190/209), a specificity of 13% (55/424), LR+ of 1.04, LR- of 0.69, PPV of 34% (190/559) and NPV of 74% (55/74). Conclusions Acoustic streaming cannot discriminate reliably between endometrioinas and other adnexal lesions, and the presence of acoustic streaming does not exclude an endometrioma. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
8.
  • Van Holsbeke, C., et al. (författare)
  • Prospective external validation of the 'ovarian crescent sign' as a single ultrasound parameter to distinguish between benign and malignant adnexal pathology
  • 2010
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 36:1, s. 81-87
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To determine the sensitivity and specificity of the 'ovarian crescent sign' (OCS) - a rim of normal ovarian tissue seen adjacent to an ipsilateral adnexal mass as a sonographic feature to discriminate between benign and malignant adnexal masses. Methods The patients included were a subgroup of patients participating in the International Ovarian Tumor Analysis (IOTA) Phase 2 study, which is an international multicenter study. The subgroup comprised 1938 patients, with an adnexal mass, recruited from 19 ultrasound centers in different countries. All patients were scanned using the same standardized ultrasound protocol. Information on more than 40 demographic and ultrasound variables were collected, but the evaluation of the OCS was optional. Only patients from centers that had evaluated the OCS in >= 90% of their cases were included. The gold standard was the histological diagnosis of the adnexal mass. The ability of the OCS to discriminate between borderline or invasively malignant vs. benign adnexal masses, as well as between invasively malignant vs. other (benign and borderline) tumors, was determined and compared with the performance of subjective evaluation of ultrasound findings by the ultrasound examiner. Results The OCS was evaluated in 1377 adnexal masses from 12 centers, 938 (68%) masses being benign, 86 (6%) borderline, 305 (22%) primary invasive and 48 (3%) metastases. The OCS was present in 398 (42%) of 938 benign masses, in 14 (16%) of 86 borderline tumors, in 18 (6%) of 305 primary invasive tumors (one malignant struma ovarii, one uterine clear cell adenocarcinoma and 16 epithelial carcinomas, i.e. four Stage I and 12 Stage II-IV) and in two (4%) of 48 ovarian metastases. Hence, the sensitivity and specificity for absent OCS to identify a malignancy was 92% and 42%, respectively, and the positive and negative likelihood ratios (LR+ and LR-, respectively) were 1.60 and 0.18. Subjective impression performed significantly better than the OCS. Sensitivity and specificity were 90% and 92%, respectively, LR+ was 11.0 and LR- was 0.10. For discrimination between invasive vs. benign or borderline tumors, the sensitivity for absent OCS was 94%, the specificity was 40%, the LR+ was 1.58 and the LR- was 0.14. Conclusion This study confirms previous reports that the presence of the OCS decreases the likelihood of invasive malignancy in adnexal masses. However it is a poor discriminator between benign and malignant adnexal masses. Copyright (C) 2010 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
9.
  •  
10.
  • Boyajian, T., et al. (författare)
  • Stellar diameters and temperatures - VI. High angular resolution measurements of the transiting exoplanet host stars HD 189733 and HD 209458 and implications for models of cool dwarfs
  • 2015
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : Oxford University Press (OUP). - 0035-8711 .- 1365-2966. ; 447:1, s. 846-857
  • Tidskriftsartikel (refereegranskat)abstract
    • We present direct radii measurements of the well-known transiting exoplanet host stars HD 189733 and HD 209458 using the CHARA Array interferometer. We find the limb-darkened angular diameters to be thetaLD = 0.3848 +/- 0.0055 and 0.2254 +/- 0.0072 milliarcsec for HD 189733 and HD 209458, respectively. HD 189733 and HD 209458 are currently the only two transiting exoplanet systems where detection of the respective planetary companion's orbital motion from high resolution spectroscopy has revealed absolute masses for both star and planet. We use our new measurements together with the orbital information from radial velocity and photometric time series data, Hipparcos distances, and newly measured bolometric fluxes to determine the stellar effective temperatures (Teff = 4875 +/- 43, 6093 +/- 103 K), stellar linear radii (R* = 0.805 +/- 0.016, 1.203 +/- 0.061 Rsun), mean stellar densities (rho* = 1.62 +/- 0.11, 0.58 +/- 0.14 rhosun), planetary radii (Rp = 1.216 +/- 0.024, 1.451 +/- 0.074 RJup), and mean planetary densities (rhop = 0.605 +/- 0.029, 0.196 +/- 0.033 rhoJup) for HD 189733 b and HD 209458 b, respectively. The stellar parameters for HD 209458, a F9 dwarf, are consistent with indirect estimates derived from spectroscopic and evolutionary modeling. However, we find that models are unable to reproduce the observational results for the K2 dwarf, HD 189733. We show that, for stellar evolutionary models to match the observed stellar properties of HD 189733, adjustments lowering the solar-calibrated mixing length parameter from 1.83 to 1.34 need to be employed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy