SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Van Mieghem Nicolas M) "

Sökning: WFRF:(Van Mieghem Nicolas M)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • van den Berg, Victor J, et al. (författare)
  • IgM anti-malondialdehyde low density lipoprotein antibody levels indicate coronary heart disease and necrotic core characteristics in the Nordic Diltiazem (NORDIL) study and the Integrated Imaging and Biomarker Study 3 (IBIS-3)
  • 2018
  • Ingår i: EBioMedicine. - : Elsevier BV. - 2352-3964. ; 36, s. 63-72
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Certain immunoglobulins (Ig) are proposed to have protective functions in atherosclerosis.Objectives: We tested whether serum levels of IgG and IgM autoantibodies against malondialdehyde low density lipoprotein (MDA-LDL) are associated with clinical coronary heart disease (CHD) and unfavorable plaque characteristics.Methods: NORDIL was a prospective study investigating adverse cardiovascular outcomes in hypertensive patients. IBIS-3 analyzed lesions in a non-culprit coronary artery with <50% stenosis using radiofrequency intravascular ultrasound (RF-IVUS) and near-infrared spectroscopy (NIRS). Imaging was repeated after a median of 386?days on rosuvastatin. Associations of antibodies with incident CHD and imaging parameters were assessed in the two sub-studies respectively.Findings: From 10,881 NORDIL patients, 87 had serum sampled at baseline and developed CHD over 4.5 years, matched to 227 controls. Higher titers of IgM anti-MDA-LDL had a protective effect on adverse outcomes, with odds ratio 0.29 (0.11, 0.76; p=0.012; p=0.016 for trend). Therefore, the effect was explored at the lesional level in IBIS-3. 143 patients had blood samples and RF-IVUS measurements available, and NIRS was performed in 90 of these. At baseline, IgM anti-MDA-LDL levels had a strong independent inverse relationship with lesional necrotic core volume (p=0.027) and percentage of plaque occupied by necrotic core (p=0.011), as well as lipid core burden index (p=0.024) in the worst 4 mm segment.Interpretation: Our study supports the hypothesis that lower circulating levels of IgM anti-MDA-LDL are associated with clinical CHD development, and for the first time relates these findings to atherosclerotic plaque characteristics that are linked to vulnerability.
  •  
2.
  • Tzikas, Apostolos, et al. (författare)
  • Left ventricular mass regression one year after transcatheter aortic valve implantation
  • 2011
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier BV. - 0003-4975 .- 1552-6259. ; 91:3, s. 685-691
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Left ventricular (LV) hypertrophy is associated with LV diastolic dysfunction and constitutes a risk factor for cardiac morbidity and mortality. The objective of this study was to investigate the degree of LV mass regression and the changes of LV diastolic function one year after transcatheter aortic valve implantation (TAVI).METHODS:Echocardiography was performed at baseline, before discharge, and at one-year follow-up in 63 consecutive patients with severe aortic stenosis who underwent TAVI with the Medtronic CoreValve System (Medtronic Inc, Minneapolis, MN). The LV mass was calculated using the Devereux formula and indexed to body surface area.RESULTS:One-year all-cause mortality was 29%. The LV mass index decreased from 126 ± 42 g/m2 at baseline to 110 ± 30 g/m2 at one-year follow-up (p < 0.001). Left ventricular ejection fraction and LV diastolic function did not change significantly. Mean transaortic gradient decreased from 47 ± 19 mm Hg at baseline to 9 ± 5 mm Hg at discharge and 9 ± 4 mm Hg at one year (p < 0.001), and was accompanied by significant clinical improvement. More than mild paravalvular aortic regurgitation was found in 24% and 15% of patients at discharge and one-year follow-up, respectively.CONCLUSIONS:A significant regression in LV mass was found one year after TAVI. However, regression was incomplete and was not accompanied by an improvement in LV diastolic function.
  •  
3.
  • Rosseel, Liesbeth, et al. (författare)
  • Contemporary European practice in transcatheter aortic valve implantation: results from the 2022 European TAVI Pathway Registry.
  • 2023
  • Ingår i: Frontiers in cardiovascular medicine. - 2297-055X. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume.The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe.Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice.Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%).Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.
  •  
4.
  • Kim, Won Keun, et al. (författare)
  • Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice : one-yearresults of the ACURATE neo2 PMCF Study
  • 2024
  • Ingår i: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 20:1, s. 85-94
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
  •  
5.
  • Stassen, Jan, et al. (författare)
  • Managing Patients With Moderate Aortic Stenosis.
  • 2023
  • Ingår i: JACC. Cardiovascular imaging. - : Elsevier BV. - 1876-7591 .- 1936-878X.
  • Tidskriftsartikel (refereegranskat)abstract
    • Current guidelines recommend that clinical surveillance for patients with moderate aortic stenosis (AS) and aortic valve replacement (AVR) may be considered if there is an indication for coronary revascularization. Recent observational studies, however, have shown that moderate AS is associated with an increased risk of cardiovascular events and mortality. Whether the increased risk of adverse events is caused by associated comorbidities, or to the underlying moderate AS itself, is incompletely understood. Similarly, which patients with moderate AS need close follow-up or could potentially benefit from early AVR is also unknown. In this review, the authors provide a comprehensive overview of the current literature on moderate AS. They first provide an algorithm that helps to diagnose moderate AS correctly, especially when discordant grading is observed. Although the traditional focus of AS assessment has been on the valve, it is increasingly acknowledged that AS is not only a disease of the aortic valve but also of the ventricle. The authors therefore discuss how multimodality imaging can help to evaluate the left ventricular remodeling response and improve risk stratification in patients with moderate AS. Finally, they summarize current evidence on the management of moderate AS and highlight ongoing trials on AVR in moderate AS.
  •  
6.
  • Ali, Ziad A., et al. (författare)
  • Optical Coherence Tomography Characterization of Coronary Lithoplasty for Treatment of Calcified Lesions : First Description
  • 2017
  • Ingår i: JACC: Cardiovascular Imaging. - : Elsevier BV. - 1936-878X. ; 10:8, s. 897-906
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives This study sought to determine the mechanistic effects of a novel balloon-based lithoplasty system on heavily calcified coronary lesions and subsequent stent placement using optical coherence tomography (OCT). Background The Shockwave Coronary Rx Lithoplasty System (Shockwave Medical, Fremont, California) delivers localized, lithotripsy-enhanced disruption of calcium within the target lesion (i.e., lithoplasty) for vessel preparation before stent implantation. Methods We analyzed OCT findings in 31 patients in whom lithoplasty was used to treat severely calcified stenotic coronary lesions. Results After lithoplasty, intraplaque calcium fracture was identified in 43% of lesions, with circumferential multiple fractures noted in >25%. The frequency of calcium fractures per lesion increased in the most severely calcified plaques (highest tertile vs. lowest tertile; p = 0.009), with a trend toward greater incidence of calcium fracture (77.8% vs. 22.2%; p = 0.057). Post-lithoplasty, mean acute area gain was 2.1 mm2, which further increased with stent implantation, achieving a minimal stent area of 5.94 ± 1.98 mm2 and mean stent expansion of 112.0 ± 37.2%. Deep dissections, as part of the angioplasty effect, occurred in 13% of cases and were successfully treated with stent implantation without incidence of acute closure, slow flow/no reflow, or perforation. Conclusions High-resolution imaging by OCT delineated calcium modification with fracture as a major mechanism of action of lithoplasty in vivo and demonstrated efficacy in the achievement of significant acute area gain and favorable stent expansion.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy