SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vanky Farkas) "

Sökning: WFRF:(Vanky Farkas)

  • Resultat 1-10 av 76
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Appel, Carl-Fredrik, et al. (författare)
  • Transcatheter versus surgical treatment for aortic stenosis : Patient selection and early outcome
  • 2012
  • Ingår i: Scandinavian Cardiovascular Journal. - : Informa Healthcare. - 1401-7431 .- 1651-2006. ; 46:5, s. 301-307
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives. To describe short-term clinical and echocardiography outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). To explore patient selection criteria for treatment with TAVI. Design. TAVI patients (n = 45) were matched to SAVR patients (n = 45) with respect to age within +/- 10 years, sex and systolic left ventricular function. Results. TAVI patients were older, 82 +/- 8 versus 78 +/- 5 years (p = 0.005) and they had higher logEuroSCORE, 16 +/- 11% versus 8 +/- 4% (p andlt; 0.001). There were no significant differences in 30 days mortality, stroke and myocardial infarction. TAVI patients received less erythrocyte (53% vs. 78%, p = 0.03) and thrombocyte (7% vs. 27%, p = 0.02) transfusions. Postoperative atrial fibrillation was less common (18% vs. 60%, p andlt; 0.001) in the TAVI group. Paravalvular regurgitation was more common in TAVI patients (87% vs. 0%, p andlt; 0.001) and 27% had access site complications. Aortic transvalvular velocity was 2.3 +/- 0.4 m/s versus 2.6 +/- 0.5 m/s (p = 0.002) and mean valve pressure gradient was 12 +/- 4 mmHg versus 15 +/- 5 mmHg (p = 0.01) in the TAVI and SAVR groups, respectively. Twenty-nine (64%) of the TAVI patients had logEuroSCORE andlt; 15%. Conclusions. Both TAVI and SAVR have good short term clinical outcome with excellent hemodynamic result. In clinical practice, factors other than high logEuroSCORE play an important role in patient selection for TAVI.
  •  
2.
  •  
3.
  •  
4.
  • Boano, Gabriella, et al. (författare)
  • Biochemical response to cryothermal and radiofrequency exposure of the human myocardium at surgical ablation of atrial fibrillation : a randomized controlled trial
  • 2020
  • Ingår i: Translational Medicine Communications. - : BioMed Central (BMC). - 2396-832X. ; 5
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Surgical cryothermia and radiofrequency (RF) ablations for atrial fibrillation (AF) seem to result in similar sinus rhythm restoration, but the biochemical consequences of the two methods are unclear. We aimed to compare the biochemical responses to the two ablative methods in concomitant mitral valve surgery (MVS).Methods: Sixty mitral valve surgery patients with AF were prospectively included. Forty-one patients planned for ablation were randomized to cryothermia (n = 20) or radiofrequency (n = 21) ablation and 19 served as controls. Markers for myocardial injury, inflammation, cell stress, apoptosis, and heart failure were analyzed pre- and postoperatively at different time points.Results: Troponin T and creatine kinase isoenzyme MB (CK-MB) peak levels were significantly higher in the cryothermia group compared with the RF group (12,805 [6140–15,700] vs. 2790 [1880–4180] ng/L; P = 0.002 and 271 [217–357] vs. 79 [66–93] μg/L; P < 0.001, respectively). Both groups had significantly higher levels than the no-ablation group. There were no group differences in C-reactive protein (CRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP), but there were correlations between pre- and postoperative levels of both CRP (rs = 0.41, P = 0.001) and NT-proBNP (rs = 0.48, P < 0.001). Protease-activated receptor 1 (PAR-1) and heat shock protein 27 (HSP27) were significantly increased in the cryoablation group.Conclusions: Cryoablation results in a larger myocardial injury and possibly more elevated apoptotic activity and cell stress compared with the RF technique. The type of ablation device did not have any significant influence on the postoperative inflammatory response nor on the early postoperative levels of NT-proBNP.
  •  
5.
  • Boano, Gabriella, et al. (författare)
  • Cox-maze IV cryoablation and postoperative heart failure in mitral valve surgery patients
  • 2017
  • Ingår i: Scandinavian Cardiovascular Journal. - : Taylor & Francis. - 1401-7431 .- 1651-2006. ; 51:1, s. 15-20
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The indications for and the risk and benefit of concomitant surgical ablation for atrial fibrillation (AF) have not been fully delineated. Our aim was to survey whether the Cox-maze IV procedure is associated with postoperative heart failure (PHF) or other adverse short-term outcomes after mitral valve surgery (MVS).DESIGN: Consecutive patients with AF undergoing MVS with (n = 50) or without (n = 66) concomitant Cox-maze IV cryoablation were analysed regarding perioperative data and one-year mortality.RESULTS: The patients in the Maze group were younger, were in lower NYHA classes, had better right ventricular function and had lower pulmonary artery pressure. The Maze group had 30 min longer median cross-clamp time (CCT) and 50% had PHF compared with 33% in the No-maze group, p = 0.09. Two patients in the No-maze group died within one year of surgery. Congestive heart failure (OR 4.3 [CI 95%: 1.8-10], p < 0.0001) and CCT (OR 1.03 [CI 95%: 1.01-1.04], p = 0.001) were associated with PHF.CONCLUSION: The current data cannot exclude that concomitant cryoablation increases the risk for PHF, possibly by increasing the cross clamp time.
  •  
6.
  • Boano, Gabriella, et al. (författare)
  • Effect of cryothermic and radiofrequency Cox-Maze IV ablation on atrial size and function assessed by 2D and 3D echocardiography, a randomized trial. To freeze or to burn
  • 2023
  • Ingår i: Clinical Physiology and Functional Imaging. - : WILEY. - 1475-0961 .- 1475-097X. ; 43:6, s. 431-440
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundAtrial linear scars in Cox-Maze IV procedures are achieved using Cryothermy (Cryo) or radiofrequency (RF) techniques. The subsequent postoperative left atrial (LA) reverse remodelling is unclear. We used 2- and 3-dimensional echocardiography (2-3DE) to compare the impact of Cryo and RF procedures on LA size and function 1 year after Cox-maze IV ablation concomitant with Mitral valve (MV) surgery. MethodsSeventy-two patients with MV disease and AF were randomized to Cryo (n = 35) or RF (n = 37) ablation. Another 33 patients were enroled without ablation (NoMaze). All patients underwent an echocardiogram the day before and 1 year after surgery. The LA function was assessed on 2D strain by speckle tracking and 3DE. ResultsForty-two ablated patients recovered sinus rhythm (SR) 1 year after surgery. They had comparable left and right systolic ventricular function, LA volume index (LAVI), and 2D reservoir strain before surgery. At follow-up, the 3DE extracted reservoir and booster function were higher after RF (37 & PLUSMN; 10% vs. 26 & PLUSMN; 6%; p < 0.001) than Cryo ablation (18 & PLUSMN; 9 vs. 7 & PLUSMN; 4%; p < 0.001), while passive conduit function was comparable between groups (24 & PLUSMN; 11 vs. 20 & PLUSMN; 8%; p = 0.17). The extent of LAVI reduction depended on the duration of AF preoperatively. ConclusionsSR restoration after MV surgery and maze results in LA size reduction irrespective of the energy source used. Compared to RF, the extension of ablation area produced by Cryo implies a structural LA remodelling affecting LA systolic function.
  •  
7.
  • Boano, Gabriella, 1974- (författare)
  • Surgical Ablation of Atrial Fibrillation with Cryo and Radiofrequency Concomitant to Mitral Valve Surgery : Clinical, Biochemical and Echocardiography Outcomes
  • 2023
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Atrial fibrillation (AF) is the most common arrhythmia seen in clinical practice. In cardiac surgery, the negative influence of AF on short- and long-term outcomes has made concomitant ablation procedures more common. The indications, clinical aspects, results, risks, and benefits of the additional surgical ablation are still valuable topics for discussion. This compilation thesis consists of four papers aiming to investigate some of the clinical, biochemical, and echocardiographic aspects of surgical ablation for AF (Cox-Maze IV) when performed concomitant to mitral valve surgery (MVS).Through a retrospective, case-control, single-center study, we described the impact of the Cox-Maze IV procedure added to MVS with focus on postoperative heart failure (paper I).Cryoenergy (cryo) and radiofrequency (RF) are the two different energy sources mainly used in Cox-Maze IV for AF ablation. To achieve linear scars in the atrial wall, the RF procedure uses heat damage, whereas the cryo method freezes down to -150°C. Through a prospective, randomized, longitudinal, controlled study, we compared the biochemical responses of the two ablative methods in concomitant MVS and the release of enzymes expressing myocardial injury, as well as inflammatory, cell stress, and apoptosis-specific proteins. We could show that cryo results in a larger release of markers for myocardial damage but has no impact on the early inflammatory response (paper II).Extended scar lesions resulting after maze may influence atrial function. As the left atrium plays a key role in the altered cardiac hemodynamics in AF, an echocardiographic analysis of the effects of the Cox-Maze IV procedure concomitant to MVS on the left atrium was carried out. The impacts of the two energy sources (cryo and RF) on left atrial remodeling and function had not been compared previously. Their direct effect on left atrial remodeling and mechanical function were assessed 1 year after surgery in patients with restored sinus rhythm. Sinus rhythm restoration after MVS concomitant to Cox-Maze IV results in a reduced left atrium size regardless of the energy source used. Three-dimensional echocardiography showed that, compared to RF, the extension of the ablation area produced by cryo implies major left atrium structural remodeling affecting systolic function. The negative effect on left atrium remodeling seems to be linear with the duration of the AF (paper III).An overview of the pacemaker implantation rate after the Cox-Maze IV procedure concomitant to MVS was obtained in a multicenter study using national qualitative registers (SWEDHEART, Carath, Svenska ICD- och Pacemakerregistret) (paper IV, sumbitted).Our results contribute to optimizing surgical indications and patient selection, providing a deeper understanding of the biochemical and echocardiographic changes during and after surgical ablation.
  •  
8.
  • Bydén, Moa, et al. (författare)
  • Cerebrovascular Reserve Capacity as a Predictor of Postoperative Delirium : A Pilot Study
  • 2021
  • Ingår i: Frontiers in Surgery. - : Frontiers Media S.A.. - 2296-875X. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Postoperative delirium is a common complication after cardiac surgery with cardiopulmonary bypass (CPB). Compromised regulation of the cerebral circulation may be a predisposing factor for delirium. However, the potential relationship between cerebrovascular reserve capacity and delirium is unknown. The aim of this study was to investigate if impaired cerebrovascular reserve capacity was associated with postoperative delirium.Methods: Forty-two patients scheduled for cardiac surgery with CPB were recruited consecutively. All patients underwent preoperative transcranial Doppler (TCD) ultrasound with calculation of breath-hold index (BHI). BHI < 0.69 indicated impaired cerebrovascular reserve capacity. In addition, patients were examined with preoperative neuropsychological tests such as MMSE (Mini Mental State Examination) and AQT (A Quick Test of cognitive speed). Postoperative delirium was assessed using Nursing Delirium Screening Scale (Nu-DESC) in which a score of >= 2 was considered as delirium.Results: Six patients (14%) scored high for postoperative delirium and all demonstrated impaired preoperative cerebrovascular reserve capacity. Median (25th-75th percentile) BHI in patients with postoperative delirium was significantly lower compared to the non-delirium group [0.26 (-0.08-0.44) vs. 0.83 (0.57-1.08), p = 0.002]. Preoperative MMSE score was lower in patients who developed postoperative delirium (median, 25th-75th percentile; 26.5, 24-28 vs. 28.5, 27-29, p = 0.024). Similarly, patients with postoperative delirium also displayed a slower performance during the preoperative cognitive speed test AQT color and form (mean +/- SD; 85.8 s +/- 19.3 vs. 69.6 s +/- 15.8, p = 0.043).Conclusion: The present findings suggest that an extended preoperative ultrasound protocol with TCD evaluation of cerebrovascular reserve capacity and neuropsychological tests may be valuable in identifying patients with increased risk of developing delirium after cardiac surgery.
  •  
9.
  • Charitakis, Emmanouil, et al. (författare)
  • Risk and protective factors for atrial fibrillation after cardiac surgery and valvular interventions : an umbrella review of meta-analyses
  • 2022
  • Ingår i: Open heart. - : BMJ Publishing Group. - 2053-3624. ; 9:2
  • Forskningsöversikt (refereegranskat)abstract
    • Objective Postoperative atrial fibrillation (POAF) is a common complication affecting approximately one-third of patients after cardiac surgery and valvular interventions. This umbrella review systematically appraises the epidemiological credibility of published meta-analyses of both observational and randomised controlled trials (RCT) to assess the risk and protective factors of POAF. Methods Three databases were searched up to June 2021. According to established criteria, evidence of association was rated as convincing, highly suggestive, suggestive, weak or not significant concerning observational studies and as high, moderate, low or very low regarding RCTs. Results We identified 47 studies (reporting 61 associations), 13 referring to observational studies and 34 to RCTs. Only the transfemoral transcatheter aortic valve replacement (TAVR) approach was associated with the prevention of POAF and was supported by convincing evidence from meta-analyses of observational data. Two other associations provided highly suggestive evidence, including preoperative hypertension and neutrophil/lymphocyte ratio. Three associations between protective factors and POAF presented a high level of evidence in meta-analyses, including RCTs. These associations included atrial and biatrial pacing and performing a posterior pericardiotomy. Nineteen associations were supported by moderate evidence, including use of drugs such as amiodarone, b-blockers, glucocorticoids and statins and the performance of TAVR compared with surgical aortic valve replacement. Conclusions Our study provides evidence confirming the protective role of amiodarone, b-blockers, atrial pacing and posterior pericardiotomy against POAF as well as highlights the risk of untreated hypertension. Further research is needed to assess the potential role of statins, glucocorticoids and colchicine in the prevention of POAF.
  •  
10.
  • Dagnegård, H.H., et al. (författare)
  • Survival after aortic root replacement with a stentless xenograft is determined by patient characteristics
  • 2022
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Mosby Inc.; Elsevier Inc.. - 0022-5223 .- 1097-685X. ; 164:6, s. 1712-1724
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Our objective was to examine intermediate-term survival and reinterventions in unselected patients, stratified according to indication, who received a Freestyle (Medtronic Inc, Minneapolis, Minn) bioprosthesis as a full aortic root replacement. Methods: Data from medical records were retrospectively collected for patients who had aortic root replacement using Freestyle bioprostheses between 1999 and 2018 at 6 North-Atlantic centers. Survival status was extracted from national registries and results stratified according to indication for surgery. Results: We included 1030 implantations in 1008 patients with elective indications for surgery: aneurysm (39.8%), small root (8.3%), and other (13.8%), and urgent/emergent indications: endocarditis (26.7%) and Stanford type A aortic dissection (11.4%). Across indications, 46.3% were nonelective cases and 34.0% were reoperations. Median age was 66.0 (interquartile range, 58.0-71.8) years and median follow-up was 5.0 (interquartile range, 2.6-7.9) years. Thirty-day mortality varied from 2.9% to 27.4% depending on indication. Intermediate survival for 90-day survivors with elective indications were not different from the general population standardized for age and sex (P = .95, 83, and .16 for aneurysms, small roots, and other, respectively). In contrast, patients with endocarditis and type A dissection had excess mortality (P < .001). Freedom from valve reinterventions was 95.0% and 94.4% at 5 and 8 years, respectively. In all, 52 patients (5.2%) underwent reinterventions, most because of endocarditis. Conclusions: At intermediate term follow-up this retrospective study provides further support for the use of the Freestyle bioprosthesis in the real-world setting of diverse, complex, and often high-risk aortic root replacement and suggests that outcome is determined by patient and disease, rather than by prosthesis, characteristics. © 2021 The Authors
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 76
Typ av publikation
tidskriftsartikel (37)
konferensbidrag (30)
doktorsavhandling (5)
annan publikation (3)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (55)
övrigt vetenskapligt/konstnärligt (21)
Författare/redaktör
Vánky, Farkas (49)
Svedjeholm, Rolf (43)
Friberg, Örjan (15)
Hultkvist, Henrik (8)
Nylander, Eva (6)
Boano, Gabriella (5)
visa fler...
Holm, Jonas, 1971- (5)
Tamas, Eva (4)
Jorfeldt, Lennart (4)
Walther, Sten (3)
Engvall, Jan (3)
Nielsen, Niels Erik (3)
Nilsson, Lennart (2)
Johansson, Mats (2)
Baranowski, Jacek (2)
Wallby, Lars (2)
Tamás, Éva, 1968- (2)
Appel, Carl-Fredrik (2)
Friberg, Orjan (2)
Jonasson, Jon (1)
Nilsson, L. (1)
Tsartsalis, Dimitrio ... (1)
Nilsson, Johan (1)
Pavie, A (1)
Karlsson, Lars (1)
Green, Anna, 1973- (1)
Maret, Eva (1)
Holmgren, Anders (1)
Nylander, Eva, 1951- (1)
Szabó, Zoltán, 1957- (1)
Ahn, Henrik Casimir (1)
Nielsen, Nils Erik (1)
Charitakis, Emmanoui ... (1)
Sartipy, U (1)
Alfredsson, Joakim (1)
Thulesius, Hans (1)
Walfridsson, Håkan (1)
Skoog, Susann (1)
Charitakis, Emmanoui ... (1)
Haaverstad, R. (1)
Rehnberg, Malin (1)
Gunnarsson, Cecilia (1)
Dragioti, Elena (1)
Freter, Wolfgang (1)
Ahlgren, Eva (1)
Löfstöm, Lars (1)
Löfström, Lars (1)
Trinks, Cecilia (1)
Åström Aneq, Meriam, ... (1)
Ihlemann, N (1)
visa färre...
Lärosäte
Linköpings universitet (74)
Örebro universitet (9)
Karolinska Institutet (4)
Umeå universitet (1)
Lunds universitet (1)
Linnéuniversitetet (1)
Språk
Engelska (73)
Svenska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (32)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy