SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vayssiere Christophe) "

Sökning: WFRF:(Vayssiere Christophe)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ayres-de-Campos, Diogo, et al. (författare)
  • European Association of Perinatal Medicine (EAPM), European Board and College of Obstetricians and Gynaecologists (EBCOG), European Midwives Association (EMA). Joint position statement : Substandard and disrespectful care in labour - because words matter
  • 2024
  • Ingår i: European Journal of Obstetrics, Gynecology, and Reproductive Biology. - : Elsevier. - 0301-2115 .- 1872-7654. ; 296, s. 205-207
  • Tidskriftsartikel (refereegranskat)abstract
    • Substandard or disrespectful care during labour should be of serious concern for healthcare professionals, as it can affect one of the most important events in a woman's life. Substandard care refers to the use of interventions that are not considered best -practice, to the inadequate execution of interventions, to situations where bestpractice interventions are withheld from patients, or there is lack of adequate informed consent. Disrespectful care refers to forms of verbal and non-verbal communication that affect patients' dignity, individuality, privacy, intimacy, or personal beliefs. There are many possible underlying causes for substandard and disrespectful care in labour, including difficulties in modifying behaviours, judgmental or paternalistic attitudes, personal interests and individualism, and a human tendency to make less arduous, less difficult, or less stressful clinical decisions. The term "obstetric violence" is used in some parts of the world to describe various forms of substandard and disrespectful care in labour, but suggests that it is mainly carried out by obstetricians and is a serious form of aggression, carried out with the intent to cause harm. We believe that this term should not be used, as it does not help to identify the underlying problem, its causes, or its correction. In addition, it is generally seen by obstetricians and other healthcare professionals as an unjust and offensive term, generating a defensive and less collaborative mindset. We reach out to all individuals and institutions sharing the common goal of improving women's experience during labour, to work together to address the underlying causes of substandard and disrespectful care, and to develop common strategies to deal with this problem, based on mutual comprehension, trust and respect
  •  
2.
  • Becker, Jeroen H, et al. (författare)
  • ST Analysis of the Fetal Electrocardiogram in Intrapartum Fetal Monitoring: A Meta-Analysis.
  • 2012
  • Ingår i: Obstetrics and Gynecology. - 1873-233X. ; 119:1, s. 145-154
  • Forskningsöversikt (refereegranskat)abstract
    • OBJECTIVE:: To compare the effects of ST-waveform analysis in combination with cardiotocography with conventional cardiotocography for intrapartum fetal monitoring. DATA SOURCES:: We searched MEDLINE, Embase, and PubMed for randomized controlled trials (RCTs) evaluating ST-waveform analysis for intrapartum fetal monitoring. METHODS OF STUDY SELECTION:: We identified RCTs that compared ST-waveform analysis and conventional cardiotocography for intrapartum fetal monitoring of singleton pregnancies in cephalic presentation beyond 34 weeks of gestation and evaluating at least one of the following: metabolic acidosis, umbilical cord pH less than 7.15, umbilical cord pH less than 7.10, umbilical cord pH less than 7.05, umbilical cord pH less than 7.00, Apgar scores less than 7 at 5 minutes, admittance to the neonatal intensive care unit, need for intubation, presence of hypoxic ischemic encephalopathy, perinatal death, operative delivery, and number of fetal blood samplings. TABULATION, INTEGRATION, AND RESULTS:: Five RCTs, which included 15,352 patients, met the selection criteria. Random-effects models were used to estimate the combined relative risks (RRs) of ST analysis compared with conventional cardiotocography. Compared with conventional cardiotocography, ST analysis showed a nonsignificant reduction in metabolic acidosis (RR 0.72, 95% confidence interval 0.43-1.19, number needed to treat [NNT] 357). ST analysis significantly reduced the incidence of additional fetal blood sampling (RR 0.59, 95% confidence interval 0.44-0.79, NNT 11), operative vaginal deliveries (RR 0.88, 95% confidence interval 0.80-0.97, NNT 64), and total operative deliveries (RR 0.94, 95% confidence interval 0.89-0.99, NNT 64). For other outcomes, no differences in effect were seen between ST analysis and conventional cardiotocography, or data were not suitable for meta-analysis. CONCLUSION:: The additional use of ST analysis for intrapartum monitoring reduced the incidence of operative vaginal deliveries and the need for fetal blood sampling but did not reduce the incidence of metabolic acidosis at birth.
  •  
3.
  • Schuit, Ewoud, et al. (författare)
  • Effectiveness of electronic fetal monitoring with additional ST analysis in vertex singleton pregnancies at > 36 weeks of gestation: an individual participant data metaanalysis
  • 2013
  • Ingår i: American Journal of Obstetrics and Gynecology. - : Elsevier BV. - 1097-6868 .- 0002-9378. ; 208:3, s. 1-187
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The purpose of this study was to assess the effectiveness of electronic fetal monitoring (EFM) alone and with additional ST analysis (EFM + ST) in laboring women with a singleton term pregnancy that is in cephalic presentation in the prevention of metabolic acidosis by the application of individual patient data metaanalysis. STUDY DESIGN: We conducted an individual patient data metaanalysis using data from 4 randomized trials, which enabled us to account for missing data and investigate relevant subgroups. The primary outcome was metabolic acidosis, which was defined as an umbilical cord-artery pH <7.05 and a base deficit that had been calculated in the extra cellular fluid compartment >12 mmol/L. We performed 8 explanatory subgroup analyses for 8 different endpoints. RESULTS: We analyzed data from 12,987 women and their newborn infants. Metabolic acidosis was present in 57 women (0.9%) in the EFM + ST group and 73 women (1.1%) in the EFM alone group (relative risk [RR], 0.76; 95% CI, 0.53-1.10). Compared with EFM alone, the use of EFM + ST resulted in a reduction in the frequency of instrumental vaginal deliveries (RR, 0.90; 95% CI, 0.83-0.99) and fetal blood samples (RR, 0.49; 95% CI, 0.44-0.55). Cesarean delivery rates were comparable between both groups (RR, 0.99; 95% CI, 0.91-1.09). Subgroup analyses showed that EFM + ST resulted in fewer admissions to a neonatal intensive care unit for women with a duration of pregnancy of >41 weeks (RR, 0.61; 95% CI, 0.39-0.95). CONCLUSION: EFM + ST does not reduce the risk of metabolic acidosis, but it does reduce the need for instrumental vaginal deliveries and fetal blood sampling.
  •  
4.
  • Vayssiere, Christophe, et al. (författare)
  • EUROPEAN ASSOCIATION OF PERINATAL MEDICINE (EAPM) Position statement : Use of appropriate terminology for situations related to inadequate fetal oxygenation in labor
  • 2024
  • Ingår i: European Journal of Obstetrics, Gynecology, and Reproductive Biology. - : Elsevier. - 0301-2115 .- 1872-7654. ; 294, s. 55-57
  • Tidskriftsartikel (refereegranskat)abstract
    • In high-resource countries, adverse perinatal outcomes are currently rare in term, non-malformed fetuses, undergoing labor, but they remain a leading cause of medico-legal dispute. Precise terminology is important to describe situations related to inadequate fetal oxygenation in labor, to ensure appropriate communication between healthcare professionals and adequate transmission of information to parents. This position statement provides consensus definitions from European perinatologists and midwives regarding the most appropriate terminology to describe situations related to inadequate fetal oxygenation in labor: suspected fetal hypoxia, severe newborn acidemia, newborn metabolic acidosis, and hypoxic-ischemic encephalopathy. It also identifies terms that are imprecise or nonspecific to this situation, and should therefore be avoided by healthcare professionals: fetal well-being, fetal stress, fetal distress, non-reassuring fetal state, and birth asphyxia.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy