SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vikholm Lundin Inger) "

Sökning: WFRF:(Vikholm Lundin Inger)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Anderson, Henrik, 1975- (författare)
  • Development of Electroacoustic Sensors for Biomolecular Interaction Analysis
  • 2009
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Biomolecular interaction analysis to determine the kinetics and affinity between interacting partners is important for the fundamental understanding of biology, as well as for the development of new pharmaceutical substances. A quartz crystal microbalance instrument suitable for kinetics and affinity analyses of interaction events was developed. The functionality of the sensor system was demonstrated by development of an assay for relative affinity determination of lectin-carbohydrate interactions.Sensor surfaces allowing for effective immobilization of one interacting partner is a key functionality of a biosensor. Here, three different surfaces and immobilization methods were studied. First, optimized preparation conditions for sensor surfaces based on carboxyl-terminated self assembled monolayers were developed and were demonstrated to provide highly functional biosensor surfaces with low non-specific binding. Second, a method allowing for immobilization of very acidic biomolecules based on the use of an electric field was developed and evaluated. The electric field made it possible to immobilize the highly acidic C-peptide on a carboxylated surface. Third, a method for antibody immobilization on a carboxyl surface was optimized and the influence of immobilization pH on the immobilization level and antigen binding capacity was thoroughly assessed. The method showed high reproducibility for a set of antibodies and allowed for antibody immobilization also at low pH.Three broadly different strategies to increase the sensitivity of electroacoustic sensors were explored. A QCM sensor with small resonator electrodes and reduced flow cell dimensions was demonstrated to improve the mass transport rate to the sensor surface. The use of polymers on QCM sensor surfaces to enhance the sensor response was shown to increase the response of an antibody-antigen model system more than ten-fold. Moreover, the application of high frequency thin film bulk acoustic resonators for biosensing was evaluated with respect to sensing range from the surface. The linear detection range of the thin film resonator was determined to be more than sufficient for biosensor applications involving, for instance, antibody-antigen interactions. Finally, a setup for combined frequency and resistance measurements was developed and was found to provide time resolved data suitable for kinetics determination.
  •  
2.
  • Ausen, Dag, et al. (författare)
  • Foresight Biomedical Sensors
  • 2007
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • The foresight study on biomedical sensors has addressed different approaches with future use of biomedical sensors in the health care sector, like: How will biomedical sensors shape the healthcare systems of the future? How can they impact the quality and cost of healthcare and what are the business opportunities in the Nordic region?
  •  
3.
  • Krupinska, Karolina, et al. (författare)
  • Detection of low levels of Escherichia coli by electrochemical impedance spectroscopy and singular value decomposition
  • 2017
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier. - 0169-7439 .- 1873-3239. ; 163, s. 49-54
  • Tidskriftsartikel (refereegranskat)abstract
    • The first steps are reported in the development of a new ultrasensitive electrochemical biosensor for detection of Escherichia coli (E. coli) in water. Two gold electrodes in a sandwich flow-cell were modified with E. coli polyclonal antibody and exposed to three different concentrations of E. coli. Electrochemical Impedance Spectroscopy was used in combination with Singular Value Decompostion of the complex numbers to monitor the interactions at the electrode surfaces. A linear regression line in the concentration range 10-1000 CFU⁎ml-1 was obtained without use of redox probes or metal nanoparticles for signal amplification.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy