SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Weedon Fekjær H.) "

Sökning: WFRF:(Weedon Fekjær H.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Konst, B., et al. (författare)
  • Image quality and radiation dose in planar imaging — Image quality figure of merits from the CDRAD phantom
  • 2019
  • Ingår i: Journal of Applied Clinical Medical Physics. - : Wiley. - 1526-9914. ; 20:7, s. 151-159
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: A contrast-detail phantom such as CDRAD is frequently used for quality assurance, optimization of image quality, and several other purposes. However, it is often used without considering the uncertainty of the results. The aim of this study was to assess two figure of merits (FOM) originating from CDRAD regarding the variations of the FOMs by dose utilized to create the x-ray image. The probability of overlapping (assessing an image acquired at a lower dose as better than an image acquired at a higher dose) was determined. Methods: The CDRAD phantom located underneath 12, 20, and 26cm PMMA was imaged 16 times at five dose levels using an x-ray system with a flat-panel detector. All images were analyzed by CDRAD Analyser, version 1.1, which calculated the FOM inverse image quality figure (IQFinv) and gave contrast detail curves for each image. Inherent properties of the CDRAD phantom were used to derive a new FOM h, which describes the size of the hole with the same diameter and depth that is just visible. Data were analyzed using heteroscedastic regression of mean and variance by dose. To ease interpretation, probabilities for overlaps were calculated assuming normal distribution, with associated bootstrap confidence intervals. Results: The proportion of total variability in IQFinv, explained by the dose (R2), was 91%, 85%, and 93% for 12, 20, and 26cm PMMA. Corresponding results for h were 91%, 89%, and 95%. The overlap probability for different mAs levels was 1% for 0.8 vs 1.2mAs, 5% for 1.2 vs 1.6mAs, 10% for 1.6 vs 2.0mAs, and 10% for 2.0mAs vs 2.5mAs for 12cm PMMA. For 20cm PMMA, it was 0.5% for 10 vs 16mAs, 13% for 16 vs 20mAs, 14% for 20 vs 25mAs, and 14% for 25 vs 32mAs. For 26cm PMMA, the probability varied from 0% to 6% for various mAs levels. Even though the estimated probability for overlap was small, the 95% confidence interval (CI) showed relatively large uncertainties. For 12cm PMMA, the associated CI for 0.8 vs 1.2mAs was 0.1–3.2%, and the CI for 1.2 vs 1.6mAs was 2.1–7.8%. Conclusions: Inverse image quality figure and h are about equally related to dose level. The FOM h, which describes the size of a hole that should be seen in the image, may be a more intuitive FOM than IQFinv. However, considering the probabilities for overlap and their confidence intervals, the FOMs deduced from the CDRAD phantom are not sensitive to dose. Hence, CDRAD may not be an optimal phantom to differentiate between images acquired at different dose levels. © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
  •  
2.
  •  
3.
  •  
4.
  • Sverre, E., et al. (författare)
  • Preventable clinical and psychosocial factors predicted two out of three recurrent cardiovascular events in a coronary population
  • 2020
  • Ingår i: BMC Cardiovascular Disorders. - : BioMed Central. - 1471-2261 .- 1471-2261. ; 20:1, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The relative importance of lifestyle, medical and psychosocial factors on the risk of recurrent major cardiovascular (CV) events (MACE) in coronary patients' needs to be identified. The main objective of this study is to estimate the association between potentially preventable factors on MACE in an outpatient coronary population from routine clinical practice. Methods This prospective follow-up study of recurrent MACE, determine the predictive impact of risk factors and a wide range of relevant co-factors recorded at baseline. The baseline study included 1127 consecutive patients 2-36 months after myocardial infarction (MI) and/or revascularization procedure. The primary composite endpoint of recurrent MACE defined as CV death, hospitalization due to MI, revascularization, stroke/transitory ischemic attacks or heart failure was obtained from hospital records. Data were analysed using cox proportional hazard regression, stratified by prior coronary events before the index event. Results During a mean follow-up of 4.2 years from study inclusion (mean time from index event to end of study 5.7 years), 364 MACE occurred in 240 patients (21, 95% confidence interval: 19 to 24%), of which 39 were CV deaths. In multi-adjusted analyses, the strongest predictor of MACE was not taking statins (Relative risk [RR] 2.13), succeeded by physical inactivity (RR 1.73), peripheral artery disease (RR 1.73), chronic kidney failure (RR 1.52), former smoking (RR 1.46) and higher Hospital Anxiety and Depression Scale-Depression subscale score (RR 1.04 per unit increase). Preventable and potentially modifiable factors addressed accounted for 66% (95% confidence interval: 49 to 77%) of the risk for recurrent events. The major contributions were smoking, low physical activity, not taking statins, not participating in cardiac rehabilitation and diabetes. Conclusions Coronary patients were at high risk of recurrent MACE. Potentially preventable clinical and psychosocial factors predicted two out of three MACE, which is why these factors should be targeted in coronary populations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy