SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Weisshaar K) "

Sökning: WFRF:(Weisshaar K)

  • Resultat 1-10 av 33
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Chalmers, J. R., et al. (författare)
  • Report from the fourth international consensus meeting to harmonize core outcome measures for atopic eczema/dermatitis clinical trials (HOME initiative)
  • 2016
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 0007-0963 .- 1365-2133. ; 175:1, s. 69-79
  • Tidskriftsartikel (refereegranskat)abstract
    • This article is a report of the fourth meeting of the Harmonising Outcome Measures for Eczema (HOME) initiative held in Malmo, Sweden on 23-24 April 2015 (HOME IV). The aim of the meeting was to achieve consensus over the preferred outcome instruments for measuring patient-reported symptoms and quality of life for the HOME core outcome set for atopic eczema (AE). Following presentations, which included data from systematic reviews, consensus discussions were held in a mixture of whole group and small group discussions. Small groups were allocated a priori to ensure representation of different stakeholders and countries. Decisions were voted on using electronic keypads. For the patient-reported symptoms, the group agreed by vote that itch, sleep loss, dryness, redness/inflamed skin and irritated skin were all considered essential aspects of AE symptoms. Many instruments for capturing patient-reported symptoms were discussed [ including the Patient-Oriented SCOring Atopic Dermatitis index, Patient-Oriented Eczema Measure (POEM), Self-Administered Eczema Area and Severity Index, Itch Severity Scale, Atopic Dermatitis Quickscore and the Nottingham Eczema Severity Score] and, by consensus, POEM was selected as the preferred instrument to measure patient-reported symptoms. Further work is needed to determine the reliability and measurement error of POEM. Further work is also required to establish the importance of pain/soreness and the importance of collecting information regarding the intensity of symptoms in addition to their frequency. Much of the discussion on quality of life concerned the Dermatology Life Quality Index and Quality of Life Index for Atopic Dermatitis; however, consensus on a preferred instrument for measuring this domain could not be reached. In summary, POEM is recommended as the HOME core outcome instrument for measuring AE symptoms.
  •  
2.
  • Warr, N., et al. (författare)
  • The Miniball spectrometer
  • 2013
  • Ingår i: European Physical Journal A. Hadrons and Nuclei. - : Springer Science and Business Media LLC. - 1434-6001. ; 49:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The Miniball germanium detector array has been operational at the REX (Radioactive ion beam EXperiment) post accelerator at the Isotope Separator On-Line facility ISOLDE at CERN since 2001. During the last decade, a series of successful Coulomb excitation and transfer reaction studies have been performed with this array, utilizing the unique and high-quality radioactive ion beams which are available at ISOLDE. In this article, an overview is given of the technical details of the full Miniball setup, including a description of the.-ray and particle detectors, beam monitoring devices and methods to deal with beam contamination. The specific timing properties of the REX-ISOLDE facility are highlighted to indicate the sensitivity that can be achieved with the full Miniball setup. The article is finalized with a summary of some physics highlights at REX-ISOLDE and the utilization of the Miniball germanium detectors at other facilities.
  •  
3.
  • Chalmers, J. R., et al. (författare)
  • Report from the fifth international consensus meeting to harmonize core outcome measures for atopic eczema/dermatitis clinical trials (HOME initiative)
  • 2018
  • Ingår i: British Journal of Dermatology. - : John Wiley & Sons. - 0007-0963 .- 1365-2133. ; 178:5, s. E332-E341
  • Tidskriftsartikel (refereegranskat)abstract
    • This is the report from the fifth meeting of the Harmonising Outcome Measures for Eczema initiative (HOME V). The meeting was held on 12-14 June 2017 in Nantes, France, with 81 participants. The main aims of the meeting were (i) to achieve consensus over the definition of the core domain of long-term control and how to measure it and (ii) to prioritize future areas of research for the measurement of the core domain of quality of life (QoL) in children. Moderated whole-group and small-group consensus discussions were informed by presentations of qualitative studies, systematic reviews and validation studies. Small-group allocations were performed a priori to ensure that each group included different stakeholders from a variety of geographical regions. Anonymous whole-group voting was carried out using handheld electronic voting pads according to pre-defined consensus rules. It was agreed by consensus that the long-term control domain should include signs, symptoms, quality of life and a patient global instrument. The group agreed that itch intensity should be measured when assessing long-term control of eczema in addition to the frequency of itch captured by the symptoms domain. There was no recommendation of an instrument for the core outcome domain of quality of life in children, but existing instruments were assessed for face validity and feasibility, and future work that will facilitate the recommendation of an instrument was agreed upon.
  •  
4.
  • Akkoyun, S., et al. (författare)
  • AGATA - Advanced GAmma Tracking Array
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 0167-5087 .- 1872-9576. ; 668, s. 26-58
  • Tidskriftsartikel (refereegranskat)abstract
    • The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation γ-ray spectrometer. AGATA is based on the technique of γ-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a γ ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realisation of γ-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterisation of the crystals was measured and compared with detector- response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximise its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer. © 2011 Elsevier B.V. All rights reserved.
  •  
5.
  •  
6.
  • Ekström, Andreas, et al. (författare)
  • Electric quadrupole moments of the 2(1)(+) states in Cd-100,Cd-102,Cd-104
  • 2009
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 80:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Using the REX-ISOLDE facility at CERN the Coulomb excitation cross sections for the 0(gs)(+)-> 2(1)(+) transition in the beta-unstable isotopes Cd-100,Cd-102,Cd-104 have been measured for the first time. Two different targets were used, which allows for the first extraction of the static electric quadrupole moments Q(2(1)(+)) in Cd-102,Cd-104. In addition to the B(E2) values in Cd-102,Cd-104, a first experimental limit for the B(E2) value in Cd-100 is presented. The data was analyzed using the maximum likelihood method. The provided probability distributions impose a test for theoretical predictions of the static and dynamic moments. The data are interpreted within the shell-model using realistic matrix elements obtained from a G-matrix renormalized CD-Bonn interaction. In view of recent results for the light Sn isotopes the data are discussed in the context of a renormalization of the neutron effective charge. This study is the first to use the reorientation effect for post-accelerated short-lived radioactive isotopes to simultaneously determine the B(E2) and the Q(2(1)(+)) values.
  •  
7.
  •  
8.
  •  
9.
  • Kester, O., et al. (författare)
  • Accelerated radioactive beams from REX-ISOLDE
  • 2003
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. - 0168-583X. ; 204, s. 20-20
  • Konferensbidrag (refereegranskat)abstract
    • In 2001 the linear accelerator of the Radioactive beam EXperiment (REX-ISOLDE) delivered for the first time accelerated radioactive ion beams, at a beam energy of 2 MeV/u. REX-ISOLDE uses the method of charge-state breeding, in order to enhance the charge state of the ions before injection into the LINAC. Radioactive singly-charged ions from the on-line mass separator ISOLDE are first accumulated in a Penning trap, then charge bred to an A/q
  •  
10.
  • Kröll, Th, et al. (författare)
  • Quadrupole Collectivity of neutron-rich nuclei around 132Sn
  • 2008
  • Ingår i: Frontiers in Nuclear Structure, Astrophysics, and Reactions, FINUSTAR 2007. - : AIP. - 9780735405325 ; 1012, s. 296-299
  • Konferensbidrag (refereegranskat)abstract
    • We report on the "safe" Coulomb excitation of neutron-rich Cd, Xe, and Ba isotopes in the vicinity of the doubly-magic nucleus 132Sn. The radioactive nuclei have been produced by ISOLDE at CERN and postaccelerated by the REX-ISOLDE facility. The γ-decay of excited states has been detected by the MINIBALL array. The presented preliminary results for the B(E2) values are consistent with expectations from phenomenological systematics and will be compared with theoretical calculations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 33

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy