1. |
- Kester, O., et al.
(författare)
-
Accelerated radioactive beams from REX-ISOLDE
- 2003
-
Ingår i: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. - 0168-583X. ; 204, s. 20-20
-
Konferensbidrag (refereegranskat)abstract
- In 2001 the linear accelerator of the Radioactive beam EXperiment (REX-ISOLDE) delivered for the first time accelerated radioactive ion beams, at a beam energy of 2 MeV/u. REX-ISOLDE uses the method of charge-state breeding, in order to enhance the charge state of the ions before injection into the LINAC. Radioactive singly-charged ions from the on-line mass separator ISOLDE are first accumulated in a Penning trap, then charge bred to an A/q
|
|
2. |
|
|
3. |
|
|
4. |
- Knoepp, F., et al.
(författare)
-
Development of a Gas-Tight Microfluidic System for Raman Sensing of Single Pulmonary Arterial Smooth Muscle Cells Under Normoxic/Hypoxic Conditions
- 2018
-
Ingår i: Sensors. - Basel, Switzerland : MDPI. - 1424-8220. ; 10
-
Tidskriftsartikel (refereegranskat)abstract
- Acute hypoxia changes the redox-state of pulmonary arterial smooth muscle cells (PASMCs). This might influence the activity of redox-sensitive voltage-gated K⁺-channels (Kv-channels) whose inhibition initiates hypoxic pulmonary vasoconstriction (HPV). However, the molecular mechanism of how hypoxia-or the subsequent change in the cellular redox-state-inhibits Kv-channels remains elusive. For this purpose, a new multifunctional gas-tight microfluidic system was developed enabling simultaneous single-cell Raman spectroscopic studies (to sense the redox-state under normoxic/hypoxic conditions) and patch-clamp experiments (to study the Kv-channel activity). The performance of the system was tested by optically recording the O₂-content and taking Raman spectra on murine PASMCs under normoxic/hypoxic conditions or in the presence of H₂O₂. Oxygen sensing showed that hypoxic levels in the gas-tight microfluidic system were achieved faster, more stable and significantly lower compared to a conventional open system (1.6 ± 0.2%, respectively 6.7 ± 0.7%, n = 6, p < 0.001). Raman spectra revealed that the redistribution of biomarkers (cytochromes, FeS, myoglobin and NADH) under hypoxic/normoxic conditions were improved in the gas-tight microfluidic system (p-values from 0.00% to 16.30%) compared to the open system (p-value from 0.01% to 98.42%). In conclusion, the new redox sensor holds promise for future experiments that may elucidate the role of Kv-channels during HPV.
|
|
5. |
|
|
6. |
|
|
7. |
|
|
8. |
|
|