SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Werther Evaldsson Anna) "

Sökning: WFRF:(Werther Evaldsson Anna)

  • Resultat 1-10 av 19
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Bakos, Zoltan, et al. (författare)
  • Cardiovascular drug utilization post-implant is related to clinical outcome in heart failure patients receiving cardiac resynchronization therapy
  • 2017
  • Ingår i: Cardiology Journal. - 1898-018X. ; 24:4, s. 374-384
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In select patients with heart failure, cardiac resynchronization therapy (CRT) is the most common complementary treatment besides medical treatment. We aimed to assess the association between post CRT-implant changes in cardiovascular medication and cardiovascular mortality and heart failure hospitalization.METHODS: 211 patients on optimal medical therapy eligible for CRT were retrospectively included in this study (72 ± 7 years, 80% male, 66% left bundle branch block [LBBB], 48% dilated cardiomyopathy [DCMP]) and investigated at baseline and after 6 months . Follow-up with medication, biochemical markers and echocardiography was performed and 3-year mortality data was collected.RESULTS: At 6 months post-implant the cohort was divided into two groups; 157 patients had low dosage furosemide treatment (up to 40 mg) and 54 patients were treated with high dosage (> 40 mg). A composite endpoint of heart failure hospitalization and all-cause mortality was evaluated at 30 months (881 ± 267 days) after the 6-month visit. In multivariate Cox regression analysis, patients in the high dose diuretics group had a higher risk of the primary endpoint (HR 1.9 [1.1-3.4], p = 0.033), but treatment with high dose diuretics was not associated with improved clinical symptoms (r = 0.031, p = 0.64).CONCLUSIONS: High dosage of loop-diuretics was associated with worse medium-term clinical outcome in CRT treated patients. It is unclear whether there is a direct causality between these associations, or if higher prescribed dosage of loop-diuretics is just a marker of more severe disease. Higher dose loop diuretics do not necessarily improve the symptoms and may be harmful to the patient. Prospective trials are warranted to further elucidate these findings.
  •  
3.
  • BAKOS, ZOLTAN, et al. (författare)
  • Positive Response to Cardiac Resynchronization Therapy : The Role of NT-proBNP
  • 2016
  • Ingår i: International journal of cardiovascular research. - : OMICS Publishing Group. - 2324-8602. ; 5:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract Background: Cardiac resynchronization therapy (CRT) is effective, but only 60-70% of patients benefit from the therapy. Despite numerous implantations, identification of predictive factors for response is still a challenge. We sought to assess the correlation of echocardiographic and clinical response to baseline demographics in relation to change in NT-proBNP levels at 6 months. Methods: 211 patients on optimal medical therapy were included retrospectively (72 ± 10 yrs., 66% LBBB, 48% DCMP, 80% male) and investigated at baseline and 6 months later. Improvement of ≥ 1 NYHA class was used as a marker for clinical response, and >15% reduction of left ventricular end-systolic volume was used to de ne reverse remodeling. NT-proBNP levels were measured at baseline and at 6 months and were compared to echocardiographic and clinical response status.Results: Four groups were identi ed: 1) non-responder, 2) echo responder, 3) clinical responder, and 4) double responder (echo and clinical). Responders were younger (70 vs. 74 years, p=0.04), had better NYHA class (2.1 vs. 2.5, p=0.01) and had lower NT- proBNP compared to non-responders at baseline. NT-proBNP slightly increased or remained unchanged in non-responders, whereas reduction in NT-proBNP was of similar magnitude for clinical or echo responders, and was most pronounced for double responders. A reduction of NT-proBNP ≥25% separated non- responders from responders (p=0.01). No signi cant differences in NT-proBNP levels and no signi cant changes in NT-proBNP were found across the responder subgroups.Conclusion: Six-month reduction in NT-proBNP is most pronounced for “double responders, ” but was comparable in patients with either clinical or echo response. Lack of NT-proBNP reduction can help identify the non-responders for further intervention.Keywords Cardiac resynchronization therapy; Electrocardiography; Echocardiography
  •  
4.
  • Borgquist, Rasmus, et al. (författare)
  • Cardiac Resynchronization Therapy Guided by Echocardiography, MRI, and CT Imaging : A Randomized Controlled Study
  • 2020
  • Ingår i: JACC: Clinical Electrophysiology. - : Elsevier BV. - 2405-500X. ; 6:10, s. 1300-1309
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This study evaluated if selecting the left ventricular (LV) target segment by echocardiography-derived late mechanical activation, with access to multimodality imaging for scar and venous anatomy, could help to increase responder rates to cardiac resynchronization therapy (CRT). Background: LV lead placement is important for clinical outcome, but the optimal strategy for LV lead placement in CRT is still debated. Methods: This study conducted a prospective, blinded randomized controlled trial on 102 patients with indication for CRT (27% women, 46% with ischemic cardiomyopathy, 63% in New York Heart Association functional class III, 74% with left bundle branch block, and with mean ejection fraction of 23%). Optimal LV lead location was defined as the latest mechanically activated available segment (free of transmural scar), determined by radial strain echocardiography, cardiac computed tomography, and cardiac magnetic resonance (n = 70). The primary endpoint was reduction of LV end-systolic volume by ≥15% at 6 months post-implantation. Results: Patients were followed for 47 ± 21 months. Based on imaging, optimal or adjacent lead placement was feasible in 96% of all cases and was obtained in 83% of the intervention group versus 80% of the control group. Fifty-six percent of the patients were LV end-systolic volume responders compared with the control group (55%) (p = 0.96), and 71% improved ≥1 New York Heart Association functional class (74% vs. 67%; p = 0.43). Death or heart failure hospitalization within 2 years occurred in 6% (2% of the intervention group vs. 10% of the control group; p = 0.07). Conclusions: Radial strain-guided LV lead placement, in combination with multimodality imaging, did not result in increased clinical or echocardiographic response, nor in a significant reduction of death or heart failure hospitalization. (Combining Myocardial Strain and Cardiac CT to Optimize Left Ventricular Lead Placement in CRT Treatment [CRT Clinic]; NCT01426321)
  •  
5.
  • Borgquist, Rasmus, et al. (författare)
  • Targeting the latest site of left ventricular mechanical activation is associated with improved long-term outcomes for recipients of cardiac resynchronization therapy
  • 2022
  • Ingår i: Heart Rhythm O2. - : Elsevier BV. - 2666-5018. ; 3:4, s. 377-384
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Previous studies have suggested that targeting the site of latest mechanical activation of the left ventricle (LV) results in improved cardiac resynchronization therapy (CRT) outcomes. It is not known whether these benefits are sustained over medium-term follow-up. Objective: To assess the clinical outcome of imaging-guided LV lead position. Methods: We sought to assess the medium-term clinical outcome by performing a patient-level meta-analysis of 2 previously published randomized controlled trials (the “STARTER” trial and the “CRT Clinic” trial). These 2 trials compared imaging-guided LV lead placement in the latest activated scar-free segment (intervention group) to standard of care (control). Mortality and heart failure hospitalization outcomes over extended follow-up were gathered from the medical records and merged. Results were stratified for native electrocardiogram (ECG) morphology. Results: A total of 289 patients were followed for a median of 6.3 years. Seven years post implant, 47 (28%) in the intervention group had died, vs 47 (38%) in the control group (P = .13); 49 (30%) vs 53 (42%) had been hospitalized for heart failure (P = .035); and 47% vs 59% (P = .057) had reached the combined endpoint. In Kaplan-Meier analysis, patients in the intervention group had better survival free of heart failure hospitalization (P = .045) and lower risk of heart failure hospitalization (P = .019). Conclusion: Targeting the latest mechanically activated segment in CRT results in better medium-term clinical outcome, mainly driven by a reduced risk of hospitalization for heart failure. The effect was seen regardless of native ECG morphology.
  •  
6.
  • Ingvarsson, Annika, et al. (författare)
  • Echocardiographic assessment of chamber size and ventricular function during the first year after heart transplantation
  • 2021
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 41:4, s. 355-365
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Detecting changes in ventricular function after orthotopic heart transplantation (OHT) using transthoracic echocardiography (TTE) is important but interpretation of findings is complicated by lack of data on early graft adaptation. We sought to evaluate echocardiographic measures of ventricular size and function the first year following OHT including speckle tracking derived strain. We also aimed to compare echocardiographic findings to hemodynamic parameters obtained by right heart catheterization (RHC).METHODS AND RESULTS: Fifty OHT patients were examined prospectively with TTE and RHC at 1, 6, and 12 months after OHT. Left ventricle (LV) was assessed with fractional shortening, ejection fraction, and systolic tissue velocities. Right ventricular (RV) evaluation included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S´) and fractional area change (FAC). LV global longitudinal and circumferential strain and RV global longitudinal strain (GLS) and RV lateral wall strain (RVfree) were analysed. No relevant changes occurred in LV echocardiographic parameters, whereas all measures of RV function improved significantly during follow up. There was an increase in TAPSE (12.4±3.3 mm to 14.4±4.3 mm, p<0.01), FAC (36±8% to 41±8%, p<0.01), RV GLS (-15.8±3.4% to -17.8±3.6%, p<0.01) and RVfree (-15.5±3.7% to -18.6±3.6%, p<0.001). Between one and twelve months pulmonary pressures decreased, whereas pulmonary vascular resistance did not.CONCLUSION: Stable OHT recipients reached steady state regarding LV function one month after transplantation. In contrast, RV function displayed gradual improvement the first year following OHT, indicating delayed RV-adaptation as compared to the LV. Improved RV function-parameters were independent of invasively measured pulmonary pressures.
  •  
7.
  • Ingvarsson, Annika, et al. (författare)
  • Impact of bridging with left ventricular assist device on right ventricular function following heart transplantation.
  • 2022
  • Ingår i: ESC heart failure. - : Wiley. - 2055-5822. ; 9:3, s. 1864-1874
  • Tidskriftsartikel (refereegranskat)abstract
    • Patients awaiting orthotopic heart transplantation (OHT) can be bridged utilizing a left ventricular assist device (LVAD) that reduces left ventricular filling pressures, decreases pulmonary artery wedge pressure, and maintains adequate cardiac output. This study set out to examine the poorly investigated area of if and how pre-treatment with LVAD impacts right ventricular (RV) function following OHT.We prospectively evaluated 59 (LVAD n=20) consecutive OHT patients. Transthoracic echocardiography (TTE) was performed in conjunction with right heart catheterization (RHC) at 1, 6, and 12months after OHT. RV function TTE-parameters included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S'), fractional area change, two-dimensional RV global longitudinal strain and longitudinal strain from the RV lateral wall (RVfree). At 1month after OHT, the LVAD group had significantly better longitudinal RV function than the non-LVAD group: TAPSE (15±3mm vs. 12±2mm, P<0.001), RV global longitudinal strain (-19.8±2.1% vs. -14.3±2.8%, P<0.001), and RVfree (-19.8±2.3% vs. -14.1±2.9%, P<0.001). At this time point, pulmonary vascular resistance (PVR) was also lower [1.2±0.4 Wood Units (WU) vs. 1.6±0.6 WU, P<0.05] in the LVAD group compared with the non-LVAD group. At 6 and 12months, no difference was detected in any of the TTE and RHC measured parameters between the two groups. Between 1 and 12months, all parameters of RV function improved significantly in the non-LVAD group but remained unaltered in the LVAD group.Our results indicate that pre-treatment with LVAD decreases PVR and is associated with significantly better RV function early following OHT. During the first year following transplantation, RV function progressively improved in the non-LVAD group such that at 6 and 12months, no difference in RV function was detected between the groups.
  •  
8.
  • Ingvarsson, Annika, et al. (författare)
  • Impact of gender on echocardiographic characteristics in heart transplant recipients
  • 2019
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 39:4, s. 246-254
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Assessment following heart transplantation (HTx) is routinely performed using transthoracic echocardiography. Differences in long-term mortality following HTx related to donor-recipient matching have been reported, but effects of gender on cardiac size and function are not well studied. The aims of this study were to evaluate differences in echocardiographic characteristics of HTx recipients defined by gender. Methods and results: The study prospectively enrolled 123 (n = 34 female) HTx recipients of which 23 recipients was donor-recipient gender mismatched. Patients were examined with 2-dimensional echocardiography using Philips iE33 ultrasound system. Data were analysed across strata based on recipient gender and gender mismatch. Male recipients had larger left ventricular (LV) mass, thicker septal wall (P<0·001) and larger absolute LV volumes (P<0·001). Mean LV ejection fraction (EF) was higher in females (P<0·05), but no differences in conventional parameters of right ventricular (RV) function were found. Ventricular strain was higher in females than in males: LV global longitudinal strain (P<0·01), RV global longitudinal strain (P<0·05) and RV lateral free wall (P<0·05). The male group receiving a female donor heart had comparable EF and strain parameters to the female group receiving a gender-matched heart. Conclusion: We found that female recipient gender was associated with smaller chamber size, higher LV EF and better LV and RV longitudinal strain. Gender-mismatched male recipients appeared to exhibit function parameters similar to gender-matched female recipients. Our results indicate that the gender aspect, analogous to current reference guidelines in general population, should be taken into consideration when examining patients post-HTx.
  •  
9.
  • Ingvarsson, Annika, et al. (författare)
  • Normal Reference Ranges for Transthoracic Echocardiography Following Heart Transplantation
  • 2018
  • Ingår i: Journal of the American Society of Echocardiography. - : Elsevier BV. - 0894-7317. ; 31:3, s. 349-360
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Heart function following heart transplantation (HTx) is influenced by numerous factors. It is typically evaluated using transthoracic echocardiography, but reference values are currently unavailable for this context. The primary aim of the present study was to derive echocardiographic reference values for chamber size and function, including cardiac mechanics, in clinically stable HTx patients. Methods: The study enrolled 124 healthy HTx patients examined prospectively. Patients underwent comprehensive two-dimensional echocardiographic examinations according to contemporary guidelines. Results were compared with recognized reference values for healthy subjects. Results: Compared with guidelines, larger atrial dimensions were seen in HTx patients. Left ventricular (LV) diastolic volume was smaller, and LV wall thickness was increased. With respect to LV function, both ejection fraction (62 ± 7%, P < .01) and global longitudinal strain (-16.5 ± 3.3%, P < .0001) were lower. All measures of right ventricular (RV) size were greater than reference values (P < .0001), and all measures of RV function were reduced (tricuspid annular plane systolic excursion 15 ± 4 mm [. P < .0001], RV systolic tissue Doppler velocity 10 ± 6 cm/sec [. P < .0001], fractional area change 40 ± 8% [. P < .0001], and RV free wall strain -16.9 ± 4.2% [. P < .0001]). Ejection fraction and LV global longitudinal strain were significantly lower in patients with previous rejection. Conclusion: The findings of this study indicate that the distribution of routinely used echocardiographic measures differs between stable HTx patients and healthy subjects. In particular, markedly larger RV and atrial volumes and mild reductions in both LV and RV longitudinal strain were evident. The observed differences could be clinically relevant in the assessment of HTx patients, and specific reference values should be applied in this context.
  •  
10.
  • Jumatate, Raluca, et al. (författare)
  • Right ventricular stroke work index by echocardiography in adult patients with pulmonary arterial hypertension
  • 2021
  • Ingår i: BMC Cardiovascular Disorders. - : Springer Science and Business Media LLC. - 1471-2261. ; 21:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In adult patients with pulmonary arterial hypertension (PAH), right ventricular (RV) failure may worsen rapidly, resulting in a poor prognosis. In this population, non-invasive assessment of RV function is challenging. RV stroke work index (RVSWI) measured by right heart catheterization (RHC) represents a promising index for RV function. The aim of the present study was to comprehensively evaluate non-invasive measures to calculate RVSWI derived by echocardiography (RVSWIECHO) using RHC (RVSWIRHC) as a reference in adult PAH patients.METHODS: Retrospectively, 54 consecutive treatment naïve patients with PAH (65 ± 13 years, 36 women) were analyzed. Echocardiography and RHC were performed within a median of 1 day [IQR 0-1 days]. RVSWIRHC was calculated as: (mean pulmonary arterial pressure (mPAP)-mean right atrial pressure (mRAP)) x stroke volume index (SVI)RHC. Four methods for RVSWIECHO were evaluated: RVSWIECHO-1 = Tricuspid regurgitant maximum pressure gradient (TRmaxPG) x SVIECHO, RVSWIECHO-2 = (TRmaxPG-mRAPECHO) x SVIECHO, RVSWIECHO-3 = TR mean gradient (TRmeanPG) x SVIECHO and RVSWIECHO-4 = (TRmeanPG-mRAPECHO) x SVIECHO. Estimation of mRAPECHO was derived from inferior vena cava diameter.RESULTS: RVSWIRHC was 1132 ± 352 mmHg*mL*m-2. In comparison with RVSWIRHC in absolute values, RVSWIECHO-1 and RVSWIECHO-2 was significantly higher (p < 0.001), whereas RVSWIECHO-4 was lower (p < 0.001). No difference was shown for RVSWIECHO-3 (p = 0.304). The strongest correlation, with RVSWIRHC, was demonstrated for RVSWIECHO-2 (r = 0.78, p < 0.001) and RVSWIECHO-1 ( r = 0.75, p < 0.001). RVSWIECHO-3 and RVSWIECHO-4 had moderate correlation (r = 0.66 and r = 0.69, p < 0.001 for all). A good agreement (ICC) was demonstrated for RVSWIECHO-3 (ICC = 0.80, 95% CI 0.64-0.88, p < 0.001), a moderate for RVSWIECHO-4 (ICC = 0.73, 95% CI 0.27-0.87, p < 0.001) and RVSWIECHO-2 (ICC = 0.55, 95% CI - 0.21-0.83, p < 0.001). A poor ICC was demonstrated for RVSWIECHO-1 (ICC = 0.45, 95% CI - 0.18-0.77, p < 0.001). Agreement of absolute values for RVSWIECHO-1 was - 772 ± 385 (- 50 ± 20%) mmHg*mL*m-2, RVSWIECHO-2 - 600 ± 339 (-41 ± 20%) mmHg*mL*m-2, RVSWIECHO-3 42 ± 286 (5 ± 25%) mmHg*mL*m-2 and for RVSWIECHO-4 214 ± 273 (23 ± 27%) mmHg*mL*m-2.CONCLUSION: The correlation with RVSWIRHC was moderate to strong for all echocardiographic measures, whereas only RVSWIECHO-3 displayed high concordance of absolute values. The results, however, suggest that RVSWIECHO-1 or RVSWIECHO-3 could be the preferable echocardiographic methods. Prospective studies are warranted to evaluate the clinical utility of such measures in relation to treatment response, risk stratification and prognosis in patients with PAH.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 19

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy