1.
  • Bornert, Fabien, et al. (författare)
  • Comparative barrier membrane degradation over time : Pericardium versus dermal membranes
  • 2021
  • Ingår i: Clinical and Experimental Dental Research. - : Wiley. - 2057-4347. ; 7:5, s. 711-718
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The effectiveness of GBR procedures for the reconstruction of periodontal defects has been well documented. The objective of this investigation was to evaluate the degradation kinetics and biocompatibility of two resorbable collagen membranes in conjunction with a bovine xenograft material. Materials and Methods: Lower premolars and first molars were extracted from 18 male Yucatan minipigs. After 4 months of healing, standardized semi-saddle defects were created (12 mm × 8 mm × 8 mm [l˙̇ × W˙ × d]), with 10 mm between adjacent defects. The defects were filled with a bovine xenograft and covered with a either the bilayer collagen membrane (control) or the porcine pericardium-derived collagen membrane (test). Histological analysis was performed after 4, 8, and 12 weeks of healing and the amount of residual membrane evaluated. Non-inferiority was calculated using the Brunner-Langer mixed regression model. Results: Histological analysis indicated the presence of residual membrane in both groups at all time points, with significant degradation noted in both groups at 12 weeks compared to 4 weeks (p =.017). No significant difference in ranked residual membrane scores between the control and test membranes was detected at any time point. Conclusions: The pericardium-derived membrane was shown to be statistically non-inferior to the control membrane with respect to resorption kinetics and barrier function when utilized for guided bone regeneration in semi-saddle defects in minipigs. Further evaluation is necessary in the clinical setting.
  •  
2.
  • Coelho, Paulo G, et al. (författare)
  • Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs.
  • 2012
  • Ingår i: Clinical oral implants research. - : Wiley. - 1600-0501 .- 0905-7161.
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media+silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n=24) and experimental surface (n=24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torqued-to-interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P=0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive. To cite this article: Coelho PG, Granato R, Marin C, Jimbo R, Lin S, Witek L, Suzuki M, Bonfante EA. Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs. Clin. Oral Impl. Res. xx, 2011; 000-000. doi: 10.1111/j.1600-0501.2010.02150.x.
  •  
3.
  • Coelho, Paulo G., et al. (författare)
  • The in vivo effect of P-15 coating on early osseointegration
  • 2014
  • Ingår i: Journal of Biomedical Materials Research. Part B - Applied biomaterials. - : John Wiley & Sons. - 1552-4973 .- 1552-4981. ; 102:3, s. 430-440
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to evaluate mechanically and morphologically the effect of a specific peptide sequence P-15, when incorporated into implant surfaces. Three types of implants were used for the study: Group A: commercially pure titanium implant (blasted and acid etched) + electrochemical thin calcium phosphate deposition, Group B: commercially pure titanium implant (blasted and acid etched) + electrochemical thin calcium phosphate deposition + P-15 incorporation, and as control, Group C: commercially pure titanium implant (blasted and acid etched). After a topographical characterization, transcortical osteotomies were made, and all implant groups (102 implants per group) were randomly placed bilaterally in the tibiae of adult beagle dogs (n = 24). At, 1, 2, and 4 weeks post-surgery, the animals were sacrificed and the samples were retrieved for removal torque tests, for nano indentation, and for histomorphometrical analysis. The results (mean +/- 95% CI) showed that Group B (34.4 +/- 8.7%) presented statistically higher bone-to-implant contact than the other groups (A = 23.9 +/- 7.8%; C = 21.7 +/- 8.3%) at 1 week, indicating an enhanced osteogenesis due to the peptide incorporation. The results suggested that the incorporation of P-15 to implant surfaces increased its bioactivity and the effects were notable especially in the early stages of the healing process. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 430-440, 2014.
  •  
4.
  • Granato, Rodrigo, et al. (författare)
  • Osteointegrative and microgeometric comparison between micro-blasted and alumina blasting/acid etching on grade II and V titanium alloys (Ti-6Al-4V).
  • 2019
  • Ingår i: Journal of The Mechanical Behavior of Biomedical Materials. - : Elsevier. - 1751-6161 .- 1878-0180. ; 97, s. 288-295
  • Tidskriftsartikel (refereegranskat)abstract
    • This study evaluated the effect of alumina-blasted/acid-etched (AB/AE) or microabrasive blasting (C3-Microblasted) surface treatment on the osseointegration of commercially-pure Ti (grade II) and Ti-6Al-4V alloy (grade V) implants compared to as-machined surfaces. Surface characterization was performed by scanning electron microscopy and optical interferometry (IFM) to determine roughness parameters (Sa and Sq, n=3 per group). One-hundred forty-four implants were placed in the radii of 12 beagle dogs, for histological (n=72, bone-to-implant contact - BIC and bone-area-fraction occupancy -BAFO) and torque to interface failure test at 3 and 6 weeks (n=72). SEM and IFM revealed a significant increase in surface texture for AB/AE and C3-Microblasted surfaces compared to machined surface, regardless of titanium substrate. Torque-to-interface failure test showed significant increase in values from as-machined to AB/AE and to C3-Microblasted. Considering time in vivo, alloy grade, and surface treatment, the C3-microblasted presented higher mean BIC values relative to AB/AE and machined surfaces for both alloy types. BAFO levels were significantly higher for both textured surfaces groups relative to the machined group at 3 weeks, but differences were not significant between the three surfaces for each alloy type at 6 weeks. Surface treatment resulted in roughness that improved osseointegration in Grade II and V titanium substrates.
  •  
5.
  • Jimbo, Ryo, et al. (författare)
  • Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane : An Experimental Study in Dogs
  • 2012
  • Ingår i: International Journal of Biomaterials. - : Hindawi Publishing Corporation. - 1687-8787 .- 1687-8795. ; 2012
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To investigate whether porcine-derived bioresorbable pericardium membrane coverage enhances the osseointegration around implants placed in fresh extraction sockets. Study Design. Twenty-four commercially available endosseous implants were placed in the fresh extraction sockets of the mandibular first molar of mature beagles (n = 6). On one side, implants and osteotomy sites were covered with porcine-derived bioresorbable pericardium membranes, whereas on the other side, no membranes were used. After 6 weeks, samples were retrieved and were histologically processed for histomorphometric analysis. Results. The histological observation showed that bone loss and soft tissue migration in the coronal region of the implant were evident for the control group, whereas bone fill was evident up to the neck of the implant for the membrane-covered group. Bone-to-implant contact was significantly higher for the membrane-covered group compared to the control group, 75% and 45% (P < 0.02), respectively. Conclusion. The experimental membranes proved to regenerate bone around implants placed in fresh extraction sockets without soft tissue intrusion.
  •  
6.
  • Jinno, Yohei, et al. (författare)
  • In Vivo Evaluation of Dual Acid-Etched and Grit-Blasted/Acid-Etched Implants With Identical Macrogeometry in High-Density Bone
  • 2017
  • Ingår i: Implant Dentistry. - : Lamy, Wolters Kluwer. - 1056-6163 .- 1538-2982. ; 26:6, s. 815-819
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Based on the current evidence, the effect of implant macrogeometry has a significant influence on osseointegration. Thus, this study evaluated histomorphometrically and histologically the bone response to acid-etched in comparison to grit-blasted/acid-etched (GB) and machined control (C) surfaced implants possessing identical macrogeometry placed in high-density bone. MATERIALS AND METHODS: Implant surface topography of the 3 different surfaced implants has previously been characterized. The macrogeometry of the implants were conical, and healing chambers were created in the cortical regions. The 3 groups were placed in the external mandibular body of adult male sheep (n = 5). After 6 weeks in vivo, all samples were retrieved for histologic observation and histomorphometry (eg, bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]). RESULTS: No statistical difference was observed for BIC and for BAFO, although there was a tendency that the mean values for BAFO was higher for the textured surface groups. CONCLUSIONS: It is suggested that the effect of surface topography is minimal in high-density bone and osseointegration seemed to be macrogeometry dependent.
  •  
7.
  • Khan, Rehan, et al. (författare)
  • Bone Regenerative Potential of Modified Biphasic Graft Materials
  • 2015
  • Ingår i: Implant Dentistry. - : Lippincott Williams & Wilkins. - 1056-6163 .- 1538-2982. ; 24:2, s. 149-154
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the bone regenerative effect of polymer and collagen incorporation to synthetic bone graft materials. Materials and Methods: The bone ingrowth of biphasic graft materials was tested in a rabbit calvaria defect model after chemical characterization: HA/TCP (25%/75%) with collagen, HA/TCP (25%/75%) without collagen, (HA/TCP)/PLGA (85%/15%) with collagen, (HA/TCP)/PLGA (65%/35%) with collagen and a commercially available (HA/TCP)/PLGA (50%/50%) (ReOss T, Intra-Lock International, Boca Raton, FL) was used as control. After 4 and 8 weeks, the retrieved samples were subjected to histomorphometrical analysis. Results: Histomorphometry presented no significant differences concerning the bone formation between the different groups at both 4 and 8 weeks. Evidently, the (HA/TCP)/PLGA (65%/35%) with collagen presented the least amount of soft tissue incorporation within the defect. The same group possessed higher amounts of bone graft material within the defect throughout the 8-week observation period, whereas the other groups seemed to decrease in volume from 4 to 8 weeks. Conclusion: Changing the PLGA percentage to 35% within the biphasic graft material seemed to maintain its volume and prevented soft tissue migration, which could be clinically beneficial.
  •  
8.
  • Lahens, Bradley, et al. (författare)
  • Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. An experimental study in sheep
  • 2016
  • Ingår i: Journal of The Mechanical Behavior of Biomedical Materials. - : Elsevier. - 1751-6161 .- 1878-0180. ; 63, s. 56-65
  • Tidskriftsartikel (refereegranskat)abstract
    • A bone drilling concept, namely osseodensification, has been introduced for the placement of endosteal implants to increase primary stability through densification of the osteotomy walls. This study investigated the effect of osseodensification on the initial stability and early osseointegration of conical and parallel walled endosteal implants in low density bone. Five male sheep were used. Three implants were inserted in the ilium, bilaterally, totaling 30 implants (n=15 conical, and n=15 parallel). Each animal received 3 implants of each type, inserted into bone sites prepared as follows: (i) regular-drilling (R: 2 mm pilot, 3.2 mm, and 3.8 mm twist drills), (ii) clockwise osseodensification (CW), and (iii) counterclockwise (CCW) osseodensification drilling with Densah Bur (Versah, Jackson, MI, USA): 2.0 mm pilot, 2.8 mm, and 3.8 mm multi-fluted burs. Insertion torque as a function of implant type and drilling technique, revealed higher values for osseodensification relative to R-drilling, regardless of implant macrogeometry. A significantly higher bone-to-implant contact (BIC) for both osseodensification techniques (p<0.05) was observed compared to R-drilling. There was no statistical difference in BIC as a function of implant type (p=0.58), nor in bone-area-fraction occupancy (BAFO) as a function of drilling technique (p=0.22), but there were higher levels of BAFO for parallel than conic implants (p=0.001). Six weeks after surgery, new bone formation along with remodeling sites was observed for all groups. Bone chips in proximity with the implants were seldom observed in the R-drilling group, but commonly observed in the CW, and more frequently under the CCW osseodensification technique. In low-density bone, endosteal implants present higher insertion torque levels when placed in osseodensification drilling sites, with no osseointegration impairment compared to standard subtractive drilling methods.
  •  
9.
  • Lahens, Bradley, et al. (författare)
  • The effect of osseodensification drilling for endosteal implants with different surface treatments : A study in sheep.
  • 2019
  • Ingår i: Journal of Biomedical Materials Research. Part B - Applied biomaterials. - : John Wiley & Sons. - 1552-4973 .- 1552-4981. ; 107:3, s. 615-623
  • Tidskriftsartikel (refereegranskat)abstract
    • This study investigated the effects of osseodensification drilling on the stability and osseointegration of machine-cut and acid-etched endosteal implants in low-density bone. Twelve sheep received six implants inserted into the ilium, bilaterally (n = 36 acid-etched, and n = 36 as-machined). Individual animals received three implants of each surface, placed via different surgical techniques: (1) subtractive regular-drilling (R): 2.0 mm pilot, 3.2 and 3.8 mm twist drills); (2) osseodensification clockwise-drilling (CW): Densah Bur (Versah, Jackson, MI) 2.0 mm pilot, 2.8, and 3.8 mm multifluted tapered burs; and (3) osseodensification counterclockwise-drilling (CCW) Densah Bur 2.0 mm pilot, 2.8 mm, and 3.8 mm multifluted tapered burs. Insertion torque was higher in the CCW and CW-drilling compared to the R-drilling (p < 0.001). Bone-to-implant contact (BIC) was significantly higher for CW (p = 0.024) and CCW-drilling (p = 0.006) compared to the R-drilling technique. For CCW-osseodensification-drilling, no statistical difference between the acid-etched and machine-cut implants at both time points was observed for BIC and BAFO (bone-area-fraction-occupancy). Resorbed bone and bone forming precursors, preosteoblasts, were observed at 3-weeks. At 12-weeks, new bone formation was observed in all groups extending to the trabecular region. In low-density bone, endosteal implants inserted via osseodensification-drilling presented higher stability and no osseointegration impairments compared to subtractive regular-drilling technique, regardless of evaluation time or implant surface. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 00B: 000-000, 2018.
  •  
10.
  • Marin, Charles, et al. (författare)
  • Bone-Forming Capabilities of a Newly Developed NanoHA Composite Alloplast Infused with Collagen : A Pilot Study in the Sheep Mandible
  • 2013
  • Ingår i: International Journal of Dentistry. - : Hindawi Publishing Corporation. - 1687-8728 .- 1687-8736. ; 2013
  • Tidskriftsartikel (refereegranskat)abstract
    • Lateral or vertical bone augmentation has always been a challenge, since the site is exposed to constant pressure from the soft tissue, and blood supply only exists from the donor site. Although, for such clinical cases, onlay grafting with autogenous bone is commonly selected, the invasiveness of the secondary surgical site and the relatively fast resorption rate have been reported as a drawback, which motivated the investigation of alternative approaches. This study evaluated the bone-forming capability of a novel nanoHA alloplast infused with collagen graft material made from biodegradable polylactic acid/polyglycolic acid versus a control graft material with the same synthesized alloplast without the nanoHA component and collagen infiltration. The status of newly formed bone and the resorption of the graft material were evaluated at 6 weeks in vivo histologically and three dimensionally by means of 3D microcomputed tomography. The histologic observation showed that newly formed bone ingrowth and internal resorption of the block were observed for the experimental blocks, whereas for the control blocks less bone ingrowth occurred along with lower resorption rate of the block material. The three-dimensional observation indicated that the experimental block maintained the external geometry, but at the same time successfully altered the graft material into bone. It is suggested that the combination of numerous factors contributed to the bone ingrowth and the novel development could be an alternative bone grafting choice.
  •  