SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Withington S.) "

Sökning: WFRF:(Withington S.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Roelfsema, P. R., et al. (författare)
  • SPICA-A Large Cryogenic Infrared Space Telescope : Unveiling the Obscured Universe
  • 2018
  • Ingår i: Publications Astronomical Society of Australia. - : Cambridge University Press (CUP). - 1323-3580 .- 1448-6083. ; 35
  • Tidskriftsartikel (refereegranskat)abstract
    • Measurements in the infrared wavelength domain allow direct assessment of the physical state and energy balance of cool matter in space, enabling the detailed study of the processes that govern the formation and evolution of stars and planetary systems in galaxies over cosmic time. Previous infrared missions revealed a great deal about the obscured Universe, but were hampered by limited sensitivity. SPICA takes the next step in infrared observational capability by combining a large 2.5-meter diameter telescope. cooled to below 8 K, with instruments employing ultra-sensitive detectors. A combination of passive cooling and mechanical coolers will be used to cool both the telescope and the instruments. With mechanical coolers the mission lifetime is not limited by the supply of cryogen. With the combination of low telescope background and instruments with state-of-the-art detectors SPICA provides a huge advance on the capabilities of previous missions. SPICA instruments offer spectral resolving power ranging from R similar to 50 through 11 000 in the 17-230 mu m domain and R similar to 28.000 spectroscopy between 12 and 18 mu m.SPICA will provide efficient 30-37 mu m broad band mapping, and small field spectroscopic and polarimetric imaging at 100, 200 and 350 mu m. SPICA will provide infrared spectroscopy with an unprecedented sensitivity of similar to 5 x 10(-20) W m (-2) (5 sigma/1 h)-over two orders of magnitude improvement over what earlier missions. This exceptional performance leap, will open entirely new domains in infrared astronomy; galaxy evolution and metal production over cosmic time, dust formation and evolution from very early epochs onwards, the formation history of planetary systems.
  •  
2.
  •  
3.
  • Millar, Alexander J., et al. (författare)
  • Searching for dark matter with plasma haloscopes
  • 2023
  • Ingår i: Physical Review D. - : American Physical Society. - 2470-0010 .- 2470-0029. ; 107:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We summarize the recent progress of the Axion Longitudinal Plasma Haloscope (ALPHA) Consortium, a new experimental collaboration to build a plasma haloscope to search for axions and dark photons. The plasma haloscope is a novel method for the detection of the resonant conversion of light dark matter to photons. ALPHA will be sensitive to QCD axions over almost a decade of parameter space, potentially discovering dark matter and resolving the strong CP problem. Unlike traditional cavity haloscopes, which are generally limited in volume by the Compton wavelength of the dark matter, plasma haloscopes use a wire metamaterial to create a tuneable artificial plasma frequency, decoupling the wavelength of light from the Compton wavelength and allowing for much stronger signals. We develop the theoretical foundations of plasma haloscopes and discuss recent experimental progress. Finally, we outline a baseline design for ALPHA and show that a full-scale experiment could discover QCD axions over almost a decade of parameter space.
  •  
4.
  • Otto, Ernst, 1971, et al. (författare)
  • RF characterization of cold-electron bolometer integrated with a unilateral finline
  • 2012
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - 0277-786X .- 1996-756X. - 9780819491534 ; 8452, s. Art. no. 84521X-
  • Konferensbidrag (refereegranskat)abstract
    • The Cold-Electron Bolometer (CEB) is a very sensitive millimetre-wave detector with high saturation power, fast response and is easy to integrate with planar circuits. We have designed, fabricated and tested CEB detectors integrated across the slot of a unilateral finline on silicon substrate. Bolometers were fabricated using e-beam direct-write trilayer technology. The CEB performance was tested in a He3 sorption cryostat HELIOX-AC-V at a bath temperature of 310 mK. DC IV curves were measured in a current bias mode and optical response was measured by irradiating samples with signals from a black body source mounted inside the cryostat. The finline chip with CEB device was mounted in a waveguide block and connected to the readout system by bond-wires. The RF signal was focused onto the waveguide input using a horn. The signal response was obtained by comparing different IV curves in current-biased mode at different temperatures of the RF source. The response measured as a voltage difference between the IV curves taken at the source temperatures of 5 K and 20 K was about 155 μV.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy