SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Witthauer L.) "

Sökning: WFRF:(Witthauer L.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aguar-Bartolome, P., et al. (författare)
  • Measurement of the gamma p -> K-0 Sigma(+) reaction with the Crystal Ball/TAPS detectors at the Mainz Microtron
  • 2013
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 88:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The gamma p -> K-0 Sigma(+) reaction has been measured from threshold to E-gamma = 1.45 GeV (W-CM = 1.9 GeV) using the Crystal Ball and TAPS multiphoton spectrometers together with the photon tagging facility at the Mainz Microtron MAMI. In the present experiment, this reaction was searched for in the 3 pi(0)p final state, by assuming K-S(0) -> pi(0)pi(0) and Sigma(+) -> pi(0)p. The experimental results include total and differential cross sections as well as the polarization of the recoil hyperon. The new data significantly improve empirical knowledge about the gamma p -> K-0 Sigma(+) reaction in the measured energy range. The results are compared to previous measurements and model predictions. It is demonstrated that adding the present gamma p -> K-0 Sigma(+) results to existing data allowed a better description of this reaction with various models.
  •  
2.
  • Eichenlaub, Manuel, et al. (författare)
  • Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems
  • 2024
  • Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert. - 1520-9156 .- 1557-8593. ; 26:4, s. 263-275
  • Tidskriftsartikel (refereegranskat)abstract
    • Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC), that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels is suggested that enables the collection of comparator data with these characteristics. This work is an important step towards establishing a future standard for the performance evaluation of CGM systems.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy