SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Woods SW) "

Sökning: WFRF:(Woods SW)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
3.
  •  
4.
  •  
5.
  • Oliver, D, et al. (författare)
  • Prognostic accuracy and clinical utility of psychometric instruments for individuals at clinical high-risk of psychosis: a systematic review and meta-analysis
  • 2022
  • Ingår i: Molecular psychiatry. - : Springer Science and Business Media LLC. - 1476-5578 .- 1359-4184. ; 27:9, s. 3670-3678
  • Forskningsöversikt (övrigt vetenskapligt/konstnärligt)abstract
    • Accurate prognostication of individuals at clinical high-risk for psychosis (CHR-P) is an essential initial step for effective primary indicated prevention. We aimed to summarise the prognostic accuracy and clinical utility of CHR-P assessments for primary indicated psychosis prevention. Web of Knowledge databases were searched until 1st January 2022 for longitudinal studies following-up individuals undergoing a psychometric or diagnostic CHR-P assessment, reporting transition to psychotic disorders in both those who meet CHR-P criteria (CHR-P + ) or not (CHR-P−). Prognostic accuracy meta-analysis was conducted following relevant guidelines. Primary outcome was prognostic accuracy, indexed by area-under-the-curve (AUC), sensitivity and specificity, estimated by the number of true positives, false positives, false negatives and true negatives at the longest available follow-up time. Clinical utility analyses included: likelihood ratios, Fagan’s nomogram, and population-level preventive capacity (Population Attributable Fraction, PAF). A total of 22 studies (n = 4 966, 47.5% female, age range 12–40) were included. There were not enough meta-analysable studies on CHR-P diagnostic criteria (DSM-5 Attenuated Psychosis Syndrome) or non-clinical samples. Prognostic accuracy of CHR-P psychometric instruments in clinical samples (individuals referred to CHR-P services or diagnosed with 22q.11.2 deletion syndrome) was excellent: AUC = 0.85 (95% CI: 0.81–0.88) at a mean follow-up time of 34 months. This result was driven by outstanding sensitivity (0.93, 95% CI: 0.87–0.96) and poor specificity (0.58, 95% CI: 0.50–0.66). Being CHR-P + was associated with a small likelihood ratio LR + (2.17, 95% CI: 1.81–2.60) for developing psychosis. Being CHR-P- was associated with a large LR- (0.11, 95%CI: 0.06−0.21) for developing psychosis. Fagan’s nomogram indicated a low positive (0.0017%) and negative (0.0001%) post-test risk in non-clinical general population samples. The PAF of the CHR-P state is 10.9% (95% CI: 4.1–25.5%). These findings consolidate the use of psychometric instruments for CHR-P in clinical samples for primary indicated prevention of psychosis. Future research should improve the ability to rule in psychosis risk.
  •  
6.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy