1.
  • Czub, Joanna, et al. (author)
  • CALIBRATION OF LOW ENERGY X-RAY EXPERIMENTAL SETUP WITH STRONGLY FILTERED BEAM USING DATA FROM A SEMICONDUCTOR AND A THERMOLUMINESCENT DETECTORS
  • 2019
  • In: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 185:2, s. 266-273
  • Journal article (peer-reviewed)abstract
    • The calibration of low energy X-ray experimental setup with strongly filtered beam dedicated to radiobiological research was performed using the absorbed dose calculated from the data collected by two types detectors. For this purpose a semiconductor (Amptek, USA) and a thermoluminescent (Institute of Nuclear Physics, Krakow, Poland) detectors were applied. The absorbed dose in water values estimated by both detectors are in good agreement.
  •  
2.
  • Czub, Joanna, et al. (author)
  • Monte Carlo dosimetry using Fluka code and experimental dosimetry with Gafchromic EBT2 and XR-RV3 of self-built experimental setup for radiobiological studies with low-energy X-rays
  • 2020
  • In: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 96:6, s. 718-733
  • Journal article (peer-reviewed)abstract
    • Purpose: The aim of this research was to simulate self-built experimental setup for radiobiological research using X-ray diffraction C-tech tube and PW 3830 generator (PANalytical, Netherlands) and to calculate absorbed dose and to compare it with experimental dose measurements. The maximum X-ray energy was 60 keV.Materials and methods: Petri dish was specially adapted to hold biological cells during the irradiation process. Rotation of Petri dish ensured radiation homogeneity and effectiveness of rotation process was confirmed using EBT2 Gafchromic film. Monte Carlo simulation using Fluka 2011 2c.4 was used to model the setup and to calculate dose absorbed by live cells. The EBT2 and XR-RV3 Gafchromic films were used to estimate relative experimental absorbed dose.Results: The radiation homogeneity provided values with maximum deviation equal to +/- 3.5% from the average value and the absorbed dose rate was 0.9 Gy/min using simulation process and 1 Gy/min or 0.8 Gy/min using experimental methods (XR-RV3 and EBT2 Gafchromic film, respectively). All dose rate values show metrological compatibility.Conclusions: Influence of specially constructed Petri dish on absorbed dose was determined using simulations that showed that low-energy photons, emitted as characteristic line from borosilicate glass forming component of Petri dish, were source of increase in dose absorbed by cells. This experimental setup will be used to conduct radiobiological research.
  •  