SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Xini A) "

Sökning: WFRF:(Xini A)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Ortiz, AB, et al. (författare)
  • Early Findings after Implementation of Veno-Arteriovenous ECMO: A Multicenter European Experience
  • 2021
  • Ingår i: Membranes. - : MDPI AG. - 2077-0375. ; 11:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Extracorporeal membrane oxygenation (ECMO) is increasingly used to treat cardiopulmonary failure in critically ill patients. Peripheral cannulation may be complicated by a persistent low cardiac output in case of veno-venous cannulation (VV-ECMO) or by differential hypoxia (e.g., lower PaO2 in the upper than in the lower body) in case of veno-arterial cannulation (VA-ECMO) and severe impairment of pulmonary function associated with cardiac recovery. The treatment of such complications remains challenging. We report the early effects of the use of veno-arterial-venous (V-AV) ECMO in this setting. Methods: Retrospective analysis including patients from five different European ECMO centers (January 2013 to December 2016) who required V-AV ECMO. We collected demographic data as well as comorbidities and ECMO characteristics, hemodynamics, and arterial blood gas values before and immediately after (i.e., within 2 h) V-AV implementation. Results: A total of 32 patients (age 53 (interquartiles, IQRs: 31–59) years) were identified: 16 were initially supported with VA-ECMO and 16 with VV-ECMO. The median time to V-AV conversion was 2 (1–5) days. After V-AV implantation, heart rate and norepinephrine dose significantly decreased, while PaO2 and SaO2 significantly increased compared to baseline values. Lactate levels significantly decreased from 3.9 (2.3–7.1) to 2.8 (1.4–4.4) mmol/L (p = 0.048). A significant increase in the overall ECMO blood flow (from 4.5 (3.8–5.0) to 4.9 (4.3–5.9) L/min; p < 0.01) was observed, with 3.0 (2.5–3.2) L/min for the arterial and 2.8 (2.1–3.6) L/min for the venous return flows. Conclusions: In ECMO patients with differential hypoxia or persistently low cardiac output syndrome, V-AV conversion was associated with improvement in some hemodynamic and respiratory parameters. A significant increase in the overall ECMO blood flow was also observed, with similar flow distributed into the arterial and venous return cannulas.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy