SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zambra A.) "

Sökning: WFRF:(Zambra A.)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Feroci, M., et al. (författare)
  • Monitoring the hard X-ray sky with SuperAGILE
  • 2010
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 510, s. A9-
  • Tidskriftsartikel (refereegranskat)abstract
    • Context SuperAGILE is the hard X-ray monitor of the AGILE gamma ray mission, in orbit since 23 April 2007. It is an imaging experiment based on a set of four independent silicon strip detectors, equipped with one-dimensional coded masks, operating in the nominal energy range 18-60 keV. Aims. The main goal of SuperAGILE is the observation of cosmic sources simultaneously with the main gamma-ray AGILE experiment, the Gamma Ray Imaging Detector (GRID). Given its similar to steradian-wide field of view and its similar to 15 mCrab day-sensitivity, SuperAGILE is also well suited to the long-term monitoring of Galactic compact objects and the detection of bright transients. Methods. The SuperAGILE detector properties and design allow for a 6 arcmin angular resolution in each of the two independent orthogonal projections of the celestial coordinates. Photon by photon data are continuously available by means of experiment telemetry, and are used to derive images and fluxes of individual sources, with integration times depending on the source intensity and position in the field of view. Results. We report on the main scientific results achieved by SuperAGILE over its first two years in orbit, until April 2009. The scientific observations started in mid-July 2007, with the science verification phase, continuing during the complete AGILE Cycle 1 and the first similar to half of Cycle 2. Despite the largely non-uniform sky coverage, due to the pointing strategy of the AGILE mission, a few tens of Galactic sources were monitored, sometimes for unprecedently long continuous periods, leading to the detection also of several bursts and outbursts. Approximately one gamma ray burst per month was detected and localized, allowing for prompt multi-wavelength observations. A few extragalactic sources in bright states were occasionally detected as well. The light curves of sources measured by SuperAGILE are made publicly available on the web in almost real-time. To enable a proper scientific use of these, we provide the reader with the relevant scientific and technical background.
  •  
2.
  • Pellizzoni, A., et al. (författare)
  • Detection of Gamma-Ray Emission from the Vela Pulsar Wind Nebula with AGILE
  • 2010
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 327:5966, s. 663-665
  • Tidskriftsartikel (refereegranskat)abstract
    • Pulsars are known to power winds of relativistic particles that can produce bright nebulae by interacting with the surrounding medium. These pulsar wind nebulae are observed by their radio, optical, and x-ray emissions, and in some cases also at TeV (teraelectron volt) energies, but the lack of information in the gamma-ray band precludes drawing a comprehensive multiwavelength picture of their phenomenology and emission mechanisms. Using data from the AGILE satellite, we detected the Vela pulsar wind nebula in the energy range from 100 MeV to 3 GeV. This result constrains the particle population responsible for the GeV emission and establishes a class of gamma-ray emitters that could account for a fraction of the unidentified galactic gamma-ray sources.
  •  
3.
  • Pittori, C., et al. (författare)
  • First AGILE catalog of high-confidence gamma-ray sources
  • 2009
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 506:3, s. 1563-1574
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the first catalog of high-confidence gamma-ray sources detected by the AGILE satellite during observations performed from July 9, 2007 to June 30, 2008. Cataloged sources were detected by merging all the available data over the entire time period. AGILE, launched in April 2007, is an ASI mission devoted to gamma-ray observations in the 30 MeV-50 GeV energy range, with simultaneous X-ray imaging capability in the 18-60 keV band. This catalog is based on Gamma-Ray Imaging Detector (GRID) data for energies greater than 100 MeV. For the first AGILE catalog, we adopted a conservative analysis, with a high-quality event filter optimized to select gamma-ray events within the central zone of the instrument field of view (radius of 40 degrees). This is a significance-limited (4 sigma) catalog, and it is not a complete flux-limited sample due to the non-uniform first-year AGILE sky coverage. The catalog includes 47 sources, 21 of which are associated with confirmed or candidate pulsars, 13 with blazars (7 FSRQ, 4 BL Lacs, 2 unknown type), 2 with HMXRBs, 2 with SNRs, 1 with a colliding-wind binary system, and 8 with unidentified sources.
  •  
4.
  • Donnarumma, I., et al. (författare)
  • Multiwavelength Observations of 3C 454.3. II. The AGILE 2007 December Campaign
  • 2009
  • Ingår i: Astrophysical Journal Letters. - 2041-8205. ; 707:2, s. 1115-1123
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the second Astrorivelatore Gamma a Immagini Leggero (AGILE) multiwavelength campaign of the blazar 3C 454.3 during the first half of 2007 December. This campaign involved AGILE, Spitzer, Swift, Suzaku, the Whole Earth Blazar Telescope (WEBT) consortium, the Rapid Eye Mount (REM), and the Multicolor Imaging Telescopes for Survey and Monstrous Explosions (MITSuME) telescopes, offering a broadband coverage that allowed for a simultaneous sampling of the synchrotron and inverse Compton (IC) emissions. The two-week AGILE monitoring was accompanied by radio to optical monitoring by WEBT and REM, and by sparse observations in mid-infrared and soft/ hard X-ray energy bands performed by means of Target of Opportunity observations by Spitzer, Swift, and Suzaku, respectively. The source was detected with an average flux of similar to 250 x 10(-8) photons cm(-2) s(-1) above 100 MeV, typical of its flaring states. The simultaneous optical and gamma-ray monitoring allowed us to study the time lag associated with the variability in the two energy bands, resulting in a possible <= one-day delay of the gamma-ray emission with respect to the optical one. From the simultaneous optical and gamma-ray fast flare detected on December 12, we can constrain the delay between the gamma-ray and optical emissions within 12 hr. Moreover, we obtain three spectral energy distributions (SEDs) with simultaneous data for 2007 December 5, 13, and 15, characterized by the widest multifrequency coverage. We found that a model with an external Compton on seed photons by a standard disk and reprocessed by the broad-line regions does not describe in a satisfactory way the SEDs of 2007 December 5, 13, and 15. An additional contribution, possibly from the hot corona with T = 10(6) K surrounding the jet, is required to account simultaneously for the softness of the synchrotron and the hardness of the IC emissions during those epochs.
  •  
5.
  • Giuliani, A., et al. (författare)
  • AGILE Detection of Delayed Gamma-ray Emission From the Short Gamma-Ray Burst GRB 090510
  • 2010
  • Ingår i: Astrophysical Journal Letters. - 2041-8205. ; 708:2, s. L84-L88
  • Tidskriftsartikel (refereegranskat)abstract
    • Short gamma-ray bursts (GRBs), typically lasting less than 2 s, are a special class of GRBs of great interest. We report the detection by the AGILE satellite of the short GRB 090510 which shows two clearly distinct emission phases: a prompt phase lasting similar to 200 ms and a second phase lasting tens of seconds. The prompt phase is relatively intense in the 0.3-10 MeV range with a spectrum characterized by a large peak/cutoff energy near 3 MeV; in this phase, no significant high-energy gamma-ray emission is detected. At the end of the prompt phase, intense gamma-ray emission above 30 MeV is detected showing a power-law time decay of the flux of the type t(-1.3) and a broadband spectrum remarkably different from that of the prompt phase. It extends from sub-MeV to hundreds of MeV energies with a photon index alpha similar or equal to 1.5. GRB 090510 provides the first case of a short GRB with delayed gamma-ray emission. We present the timing and spectral data of GRB 090510 and briefly discuss its remarkable properties within the current models of gamma-ray emission of short GRBs.
  •  
6.
  • Longo, F., et al. (författare)
  • Variable and transient Galactic gamma-ray sources with AGILE
  • 2011
  • Ingår i: Nuovo Cimento della Societa Italiana di Fisica C. - 1124-1896. ; 34:3, s. 191-196
  • Tidskriftsartikel (refereegranskat)abstract
    • AGILE has been providing continous monitoring of the Galactic plane in its three years of operation. Thanks to its sensitivity at energies near 100 MeV, AGILE has observed variability and transient behaviour in a number of sources. Simultaneous hard-X-ray coverage, rapid alerts to the astronomical community, and multiwavelength campaigns have provided identifications for some of these sources and placed constraints on others. We provide an overview of these observations and their possible counterparts, including microquasars and colliding wind binaries.
  •  
7.
  • Marisaldi, M., et al. (författare)
  • Detection of terrestrial gamma ray flashes up to 40 MeV by the AGILE satellite
  • 2010
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 115:3, s. A00E13-
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the detection by the Astrorivelatore Gamma a Immagini Leggero (AGILE) satellite of terrestrial gamma ray flashes (TGFs) obtained with the minicalorimeter (MCAL) detector operating in the energy range 0.3-100 MeV. We select events typically lasting a few milliseconds with spectral and directional selections consistent with the TGF characteristics previously reported by other space missions. During the period 1 June 2008 to 31 March 2009 we detect 34 high-confidence events showing millisecond durations and a geographical distribution peaked over continental Africa and Southeast Asia. For the first time, AGILE-MCAL detects photons associated with TGF events up to 40 MeV. We determine the cumulative spectral properties of the spectrum in the range 0.5-40 MeV, which can be effectively described by a Bremsstrahlung spectrum. We find that both the TGF cumulative spectral properties and their geographical distribution are in good agreement with the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) results.
  •  
8.
  • Tavani, M., et al. (författare)
  • Detection of Gamma-Ray Emission from the Eta-Carinae Region
  • 2009
  • Ingår i: ASTROPHYSICAL JOURNAL LETTERS. - 2041-8205. ; 698:2, s. L142-L146
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the results of extensive observations by the gamma-ray AGILE satellite of the Galactic region hosting the Carina nebula and the remarkable colliding wind binary Eta Carinae (eta Car) during the period 2007 July-2009 January. We detect a gamma-ray source (1AGL J1043-5931) consistent with the position of eta Car. If 1AGL J1043-5931 is associated with the Car system, our data provide the long sought first detection above 100 MeV of a colliding wind binary. The average gamma-ray flux above 100 MeV and integrated over the preperiastron period 2007 July-2008 October is F(gamma) = (37 +/- 5) x 10(-8) ph cm(-2) s(-1) corresponding to an average gamma-ray luminosity of L(gamma) = 3.4 x 10(34) erg s(-1) for a distance of 2.3 kpc. We also report a two-day gamma-ray flaring episode of 1AGL J1043-5931 on 2008 October 11-13 possibly related to a transient acceleration and radiation episode of the strongly variable shock in the system.
  •  
9.
  • Tavani, M., et al. (författare)
  • Direct Evidence for Hadronic Cosmic-Ray Acceleration in the Supernova Remnant IC 443
  • 2010
  • Ingår i: The Astrophysical Journal. Letters. - 2041-8205. ; 710:2, s. L151-L155
  • Tidskriftsartikel (refereegranskat)abstract
    • The supernova remnant (SNR) IC 443 is an intermediate-age remnant well known for its radio, optical, X-ray, and gamma-ray energy emissions. In this Letter, we study the gamma-ray emission above 100 MeV from IC 443 as obtained by the AGILE satellite. A distinct pattern of diffuse emission in the energy range 100 MeV-3 GeV is detected across the SNR with its prominent maximum (source "A") localized in the northeastern shell with a flux F = (47 +/- 10) x 10(-8) photons cm(-2) s(-1) above 100 MeV. This location is the site of the strongest shock interaction between the SNR blast wave and the dense circumstellar medium. Source "A" is not coincident with the TeV source located 0.4. away and associated with a dense molecular cloud complex in the SNR central region. From our observations, and from the lack of detectable diffuse TeV emission from its northeastern rim, we demonstrate that electrons cannot be the main emitters of gamma rays in the range 0.1-10 GeV at the site of the strongest SNR shock. The intensity, spectral characteristics, and location of the most prominent gamma-ray emission together with the absence of cospatial detectable TeV emission are consistent only with a hadronic model of cosmic-ray acceleration in the SNR. A high-density molecular cloud (cloud "E") provides a remarkable "target" for nucleonic interactions of accelerated hadrons; our results show enhanced gamma-ray production near the molecular cloud/shocked shell interaction site. IC 443 provides the first unambiguous evidence of cosmic-ray acceleration by SNRs.
  •  
10.
  • Wang, J., et al. (författare)
  • Final report of the CCQM-K145 : Toxic and essential elements in bovine liver
  • 2020
  • Ingår i: Metrologia. - : IOP Publishing Ltd. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • Liver plays a major role in metabolism and acts as a source of energy for the body by storing glycogen. With the growing interest and investigation in the biological effects in recent years, it is important and necessary to develop accurate and comparable analytical methods for elements in bio-samples. It has, however, been 10 years since the tissue sample (bovine liver) of CCQM-K49 key comparison. The purpose of CCQM-K145 is to ensure the comparable and traceable measurement results for essential and toxic elements such as P, S, Zn, Mn, Ni, Mo, Sr, Cr, Co, Pb, As and Hg in bovine liver among NMIs and other designated measurement bodies worldwide. The comparison was agreed by IAWG as 6th IAWG Benchmarking Exercise with Zn and Ni as exemplary elements at the meeting in Korea in the early October 2016. The results of CCQM-K145 are expected to cover the measurement capability and support CMCs claiming for inorganic elements in the similar biological tissue materials and food samples. 30 NMIs and DIs registered in CCQM-K145. With respect to the methodology, a variety of techniques such as IDMS, ICP-OES, ICP-MS(non-ID), AAS and NAA were adopted by the participants. For Zn, Ni, Sr, Pb and Hg measurements, most participants chose ID-ICP-MS method, which showed the better performance in terms of consistency and reliability of the measurement results. In aspect of the traceability for the measurement results in CCQM-K145, most participants used their own (in house) CRMs or other NMI's CRMs to guarantee trace to SI unit. Most participants used similar matrix CRMs for quality control or method validation. Base on different statistic way to calculate the reference mass fraction values and associated uncertainties for each measurand, removal of the suspected extreme values, and discussion at the IAWG meetings, the median values are proposed as the KCRV for Zn, Ni, Mn, Mo, Cr, Pb and Hg; the arithmetic mean values are proposed as the KCRV for P, S, Sr, Co and As. In general, the performances of the majority of CCQM-K145 participants are very good, illustrating their measurement capabilities for Zn, Ni, P, S, Mn, Mo, Sr, Cr, As, Co, Pb and Hg in a complex biological tissue matrix. Bovine liver contains many kinds of nutrients and microelements, it can be regarded as a typical representative material of biological tissue and food. In CCQM-K145, the analytes involved alkali metals and transition elements, metalloids/semi-metals and non metals with a range of mass fraction from mg/g to μg/kg. CCQM-K145 also tested the ability of NMIs/DIs to determine elements that were easy to be lost and polluted, and interfered significantly. The chemical pretreatment methods of samples used in the comparison is suitable for general food and biological matrix samples. A variety of measurement methods used in the comparison represent the main instrumental technology for elemental analysis. Therefore, for supporting CMC claim, CCQM-K145 is readily applicable to measurement of more elements in a wide range of biological materials (including liquids and solids) and meat products. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy