1. |
- Bergvinsson, Halldor, et al.
(författare)
-
Highly cross-linked polyethylene still outperforms conventional polyethylene in THA : 10-year RSA results
- 2021
-
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 92:5, s. 568-574
-
Tidskriftsartikel (refereegranskat)abstract
- Background and purpose — Cup wear in total hip arthroplasty (THA) can be affected by different manufacturing processes of the polyethylene (PE). We report the long-term wear pattern differences, as well as early creep behavior, between conventional PE and highly cross-linked PE (HXLPE) liners, as measured with radiostereometry (RSA) up to 10 years. We also compare migration and clinical outcome of 2 similar uncemented cups with different backside surface roughness. Patients and methods — We included 45 patients with primary osteoarthritis. 23 received a conventional liner and 22 an HXLPE liner in a similar uncemented cup, but with a slightly rougher surface. The patients were followed up with RSA and hip-specific outcome questionnaire (HOOS) at 3 months, 1, 2, 5, and 10 years. Results — During the first 3 months both liners showed expected deformation with mean proximal head penetration of 0.39 mm (conventional PE) and 0.21 mm (HXLPE). Between 3 months and 10 years there was a difference in annual wear with 0.12 mm/year for the conventional liner and 0.02 mm/year for the HXLPE liner. The cup with rougher surface had less initial migration but both types had stabilized after 3 months. The HOOS scores improved after surgery and remained high for both groups throughout the study period. Interpretation — Up to 10 years the HXLPE has consistent lower annual wear, possibly contributing to longer survival of the THA, compared with conventional PE. All patients reported good results regardless of liner type.
|
|
2. |
- Bergvinsson, Halldor, et al.
(författare)
-
Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily : a randomized, controlled RSA trial with 5-year follow-up
- 2022
-
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 93, s. 249-255
-
Tidskriftsartikel (refereegranskat)abstract
- Background and purpose - Vitamin E infused highly cross-linked polyethylene (VEPE) was introduced in order to enhance oxidative resistance in highly cross-linked polyethylene cups in total hip arthroplasty (THA). We have, with a follow-up of 5 years, evaluated wear characteristics of 2 identically designed cemented cups with the only difference being the material, VEPE or ultra-high molecular weight polyethylene (UHMWPE). Furthermore, we report cup migration and clinical outcome. Patients and methods - 48 patients with primary osteoarthritis were randomized to either UHMWPE or VEPE cups. Patients were followed with radiostereometric analysis (RSA) from the first postoperative day, at 3 months, 1, 2, and 5 years as well as with hip-specific outcome questionnaires. Results - At 3 months the mean proximal head penetration for UHMWPE was 0.07 mm (95% CI 0.03-0.11) and for VEPE 0.06 mm (-0.01 to 0.13). Thereafter, there was a continuous annual wear of 0.08 mm/year, up to 0.46 mm (0.36-0.57) at 5 years, for the UHMWPE cup. The VEPE cup showed low annual wear of 0.01 mm/year, up to 0.09 mm (0.02-0.16) at 5 years. In the first 3 months the UHMWPE cup migrated cranially 0.08 mm (0.03-0.13) whereas the VEPE cup migrated 0.17 mm (0.10-0.24), Thereafter, they showed similar migration patterns with stabilization between 2 and 5 years up to 0.21 mm (0.04-0.39) and 0.24 mm (0.13-0.36) respectively. The HOOS remained good up to 5 years, and no cup was revised. Interpretation - Compared with otherwise identical UHMWPE cups the cemented VEPE cup shows statistically significant reduction of wear up to 5 years and both cup types stabilize well with good clinical outcome.
|
|