SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zankl M.) "

Sökning: WFRF:(Zankl M.)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Terhal, Paulien A., et al. (författare)
  • A Study of the Clinical and Radiological Features in a Cohort of 93 Patients with a COL2A1 Mutation Causing Spondyloepiphyseal Dysplasia Congenita or a Related Phenotype
  • 2015
  • Ingår i: American Journal of Medical Genetics. Part A. - : Wiley. - 1552-4825 .- 1552-4833. ; 167A:3, s. 461-475
  • Tidskriftsartikel (refereegranskat)abstract
    • Type 2 collagen disorders encompass a diverse group of skeletal dysplasias that are commonly associated with orthopedic, ocular, and hearing problems. However, the frequency of many clinical features has never been determined. We retrospectively investigated the clinical, radiological, and genotypic data in a group of 93 patients with molecularly confirmed SEDC or a related disorder. The majority of the patients (80/93) had short stature, with radiological features of SEDC (n=64), others having SEMD (n=5), Kniest dysplasia (n=7), spondyloperipheral dysplasia (n=2), or Torrance-like dysplasia (n=2). The remaining 13 patients had normal stature with mild SED, Stickler-like syndrome or multiple epiphyseal dysplasia. Over 50% of the patients had undergone orthopedic surgery, usually for scoliosis, femoral osteotomy or hip replacement. Odontoid hypoplasia was present in 56% (95% CI 38-74) and a correlation between odontoid hypoplasia and short stature was observed. Atlanto-axial instability, was observed in 5 of the 18 patients (28%, 95% CI 10-54) in whom flexion-extension films of the cervical spine were available; however, it was rarely accompanied by myelopathy. Myopia was found in 45% (95% CI 35-56), and retinal detachment had occurred in 12% (95% CI 6-21; median age 14 years; youngest age 3.5 years). Thirty-two patients complained of hearing loss (37%, 95% CI 27-48) of whom 17 required hearing aids. The ophthalmological features and possibly also hearing loss are often relatively frequent and severe in patients with splicing mutations. Based on clinical findings, age at onset and genotype-phenotype correlations in this cohort, we propose guidelines for the management and follow-up in this group of disorders.
  •  
2.
  •  
3.
  • Lanhede, B., et al. (författare)
  • The Influence of Different Technique Factors on Image Quality for Chest Radiographs: Application of the Recent CEC Image Quality Criteria
  • 2000
  • Ingår i: Radiation Protection Dosimetry. - 1742-3406. ; 90:1-2, s. 203-206
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the first this work part of the EU-project, Trial I, was to evaluate and possibly improve the CEC image criteria for radiographic chest images. Chest images of healthy volunteers were acquired using different technique factors. The image criteria were used as a tool to discriminate between the different images. The technique factors were chosen so that the image quality would differ slightly. Four different technique parameters, each with two possible settings, used in clinical practice today, were used: tube voltage - 102 and 141 kV; screen/film speed - 160 and 320; maximum optical density in the parenchyma - 1.3 and 1.8; method for scatter reduction - air gap 30/390 and moving grid40/12. The results showed that the image criteria were able to separate between different technique groups. Some conclusions can be drawn from the results Optical density 1.8 was better than 1.3 independent of the other parameters. . Among the six combinations ranked best , four used tube voltage 141 kV and four used air gap technique for scatter reduction. No difference was seen for screen/film speed. No correlation was seen between the ranking of the systems and patient dose.
  •  
4.
  • Lanhede, B, et al. (författare)
  • The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria.
  • 2002
  • Ingår i: The British journal of radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 75:889, s. 38-49
  • Tidskriftsartikel (refereegranskat)abstract
    • The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization of a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters. In the present study, chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage (102 kVp and 141 kVp), nominal speed class (160 and 320), maximum film density (1.3 and 1.8) and method of scatter reduction (grid (R=12) and air gap). The air kerma at the entrance surface was measured for all patients and the risk-related dose H(Golem), based on calculated organ-equivalent dose conversion coefficients and the measured entrance air kerma values, was calculated. Image quality was evaluated by a group of European expert radiologists using a modified version of the CEC quality criteria. For the two density levels, density level 1.8 was significantly better than 1.3 but at the cost of a higher patient radiation exposure. The correlation between the number of fulfilled quality criteria and H(Golem) was generally poor. An air gap technique resulted in lower doses than scatter reduction with a grid but provided comparable image quality. The criteria can be used to highlight optimum radiographic technique in terms of image quality and patient dose, although not unambiguously. A recommendation for good radiographic technique based on a compromise between image quality and risk-related radiation dose to the patient is to use 141 kVp, an air gap, a screen-film system with speed 320 and an optical density of 1.8.
  •  
5.
  •  
6.
  •  
7.
  • Tingberg, Anders, et al. (författare)
  • Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.
  • 2004
  • Ingår i: The British journal of radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 77:915, s. 204-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.
  •  
8.
  • Tingberg, Anders, et al. (författare)
  • The influence of the characteristic curve on the clinical image quality and patient absorbed dose in lumbar spine radiography
  • 2001
  • Ingår i: Proceedings of SPIE. - : SPIE. - 0819440108 ; 4324, s. 41503-41503
  • Konferensbidrag (refereegranskat)abstract
    • The 'European Guidelines on Quality Criteria for Diagnostic Radiographic Images' do not address the choice of film characteristic (H/D) curve, which is an important parameter for the description of a radiographic screen-film system. Since it is not possible to investigate this influence by taking repeated exposures of the same patients on films with systematically varied H/D curves, patient images of lumbar spine were digitised in the current study. The image contrast was altered by digital image processing techniques, simulating images with H/D curves varying from flat over standard latitude to a film type steeper than a mammography film. The manipulated images were printed on film for evaluation. Seven European radiologists evaluated the clinical image quality of in total 224 images by analysing the fulfilment of the European Image Criteria and by visual grading analysis of the images. The results show that the local quality can be significantly improved by the application of films with a steeper film H/D curve compared to the standard latitude film. For images with an average optical density of about 1.25, the application of the steeper film results in a reduction of patient absorbed dose by about 10-15% without a loss of diagnostically relevant image information. The results also show that the patient absorbed dose reduction obtained by altering the tube voltage from 70 kV to 90 kV coincides with a loss of image information that cannot be compensated for by simply changing the shape of the H/D curve.
  •  
9.
  • Zankl, M., et al. (författare)
  • New calculations for internal dosimetry of beta-emitting radiopharmaceuticals
  • 2010
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 245-249
  • Tidskriftsartikel (refereegranskat)abstract
    • The calculation of absorbed dose from internally incorporated radionuclides is based on the so-called specific absorbed fractions (SAFs) which represent the fraction of energy emitted in a given source region that is absorbed per unit mass in a specific target organ. Until recently, photon SAFs were calculated using MIRD-type mathematical phantoms. For electrons, the energy released was assumed to be absorbed locally ('ICRP 30 approach'). For this work, photon and electron SAFs were derived with Monte Carlo simulations in the new male voxel-based reference computational phantom adopted by the ICRP and ICRU. The present results show that the assumption of electrons being locally absorbed is not always true at energies above 300-500 keV. For source/target organ pairs in close vicinity, high-energy electrons escaping from the source organ may result in cross-fire electron SAFs in the same order of magnitude as those from photons. Examples of organ absorbed doses per unit activity are given for F-18-choline and I-123-iodide. The impact of the new electron SAFs used for absorbed dose calculations compared with the previously used assumptions was found to be small. The organ dose coefficients for the two approaches differ by not more than 6 % for most organs. Only for irradiation of the urinary bladder wall by activity in the contents, the ICRP 30 approach presents an overestimation of approximately 40-50%.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy