SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zettersten Camilla) "

Sökning: WFRF:(Zettersten Camilla)

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bökman, C.Fredrik, et al. (författare)
  • A Setup for the Coupling of a Thin-Layer Electrochemical Flow Cell to Electrospray Mass Spectrometry
  • 2004
  • Ingår i: Analytical Chemistry. ; 76:7, s. 2017-2024
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel setup for the coupling of commercially available thin-layer cell to electrospray mass spectrometry (ESI-MS) which allows the elctrochemical reactions at the counter electrode to be straightforwardly separated from the flow into the mass spectrometer has been developed. In this way interferences from reaction products formed at the counter electrode can be minimized. This reduces the risk of changes in the mass spectra as a result of electrochemical reactions in the solution. The described setup also enables the working electrode to be positioned close to the electrospray (ESI) emitter without the need for a grounding point or a long transfer line between the electrochemical cell and the electrospray emitter. By decoupling the electrochemical reactions in the flow cell and those in the electrospray emitter, improved facilities for studies of electrochemical reactions are obtained through a better control of the potential of the working electrode. The setup has been used to study the oxidation of a drug (Olsalazine), which previously has been found to involve chemical follow-up reactions. It is also demonstrated that uncharged thiols can be detected in ESI-MS after spontaneous adsorption on a gold working electrode, followed by oxidative desorption to yield sulfinates or sulfonates. This adsorption and potential-controlled desorption has been used for the preconcentration of micromolar concentrations of 1-hexanethiol as well as for desalting of solutions containing micromolar concentrations of thiols. The results indicate that the present on-line coupling of an electrochemical cell to ESI-MS provides promising possibilities for sample preconcentration, matrix exchange (including desalting), and ionization of neutral compounds, such as thiols.
  •  
2.
  •  
3.
  • Liljegren, Gustav, et al. (författare)
  • On-line coupling of a microelectrode array equipped poly(dimethylsiloxane) microchip with an integrated graphite electrospray emitter for electrospray ionisation mass spectrometry
  • 2005
  • Ingår i: Lab on a Chip. - : Royal Society of Chemistry (RSC). - 1473-0197 .- 1473-0189. ; :5, s. 1008-1016
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane) (PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 uL min-1, respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 uL min-1. To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Liljegren, Gustav, et al. (författare)
  • On-line electrochemically controlled solid-phase extraction interfaced to electrospray and inductively coupled plasma mass spectrometry
  • 2005
  • Ingår i: The Analyst. - : Royal Society of Chemistry (RSC). - 0003-2654 .- 1364-5528. ; :130, s. 1358-1368
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrochemically controlled solid-phase extractions of anions were interfaced on-line to electrospray mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS), using polypyrrole coated electrodes and a thin-layer electrochemical (EC) flow cell. The results indicate that electrochemically controlled solid-phase extraction (EC-SPE) can be used as a versatile potential controlled sample preparation technique for a range of anions and that the properties of the polypyrrole coatings can be modified by altering the electrodeposition conditions. In the present study, the influence of interfering anions (i.e., fluoride and sulfate), and the anion used during the electropolymerisation, on the bromide extraction recovery was investigated for EC-SPE interfaced to ICP-MS. The results of these experiments show that the interference due to the presence of similar concentrations of sulfate can be reduced when using a polypyrrole coating electropolymerised in the presence of bromide ions. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurements were also used to study the morphology of the coatings, as well as the variations in the film thickness within the coatings. The effect of different desorption techniques on the bromide preconcentration factor in the ICP-MS on-line flow system was also examined. Stopped-flow desorption was found to give rise to significantly increased preconcentration factors in comparison with desorptions in flowing solutions. While the desorption efficiency depends on the type of desorption electrolyte (the electrolyte in which the desorption takes place), due to the competing influx of cations, the influence of the pH on the switching charge of the polypyrrole coating was found to be small, at constant ionic strength. To study the applicability of the EC-SPE technique with respect to real samples, investigations were also made with tap water samples spiked with different bromide concentrations. The results of these experiments, which were carried out using a modified thin-layer EC flow cell allowing in situ polymerisation of polypyrrole yielding a polymer plug covering the cross section of the channel, demonstrate that 3 uM concentrations of bromide could be detected in the tap water sample. This demonstrates that the extraction technique allows extractions of low concentrations of ions in the presence of significantly higher concentrations of other similar ions. The fact that the extraction and desorption steps are electrochemically controlled makes EC-SPE particularly well suited for inclusion in miniaturised lab-on-a-chip systems.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy