SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(van Zijl Peter C M) "

Sökning: WFRF:(van Zijl Peter C M)

  • Resultat 1-10 av 20
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Donahue, Manus J, et al. (författare)
  • Consensus statement on current and emerging methods for the diagnosis and evaluation of cerebrovascular disease
  • 2018
  • Ingår i: Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism. - 1559-7016. ; 38:9, s. 1391-1417
  • Forskningsöversikt (refereegranskat)abstract
    • Cerebrovascular disease (CVD) remains a leading cause of death and the leading cause of adult disability in most developed countries. This work summarizes state-of-the-art, and possible future, diagnostic and evaluation approaches in multiple stages of CVD, including (i) visualization of sub-clinical disease processes, (ii) acute stroke theranostics, and (iii) characterization of post-stroke recovery mechanisms. Underlying pathophysiology as it relates to large vessel steno-occlusive disease and the impact of this macrovascular disease on tissue-level viability, hemodynamics (cerebral blood flow, cerebral blood volume, and mean transit time), and metabolism (cerebral metabolic rate of oxygen consumption and pH) are also discussed in the context of emerging neuroimaging protocols with sensitivity to these factors. The overall purpose is to highlight advancements in stroke care and diagnostics and to provide a general overview of emerging research topics that have potential for reducing morbidity in multiple areas of CVD.
  •  
2.
  • Huang, Jianpan, et al. (författare)
  • Altered d-glucose in brain parenchyma and cerebrospinal fluid of early Alzheimer's disease detected by dynamic glucose-enhanced MRI
  • 2020
  • Ingår i: Science Advances. - : American Association for the Advancement of Science (AAAS). - 2375-2548. ; 6:20
  • Tidskriftsartikel (refereegranskat)abstract
    • Altered cerebral glucose uptake is one of the hallmarks of Alzheimer's disease (AD). A dynamic glucose-enhanced (DGE) magnetic resonance imaging (MRI) approach was developed to simultaneously monitor d-glucose uptake and clearance in both brain parenchyma and cerebrospinal fluid (CSF). We observed substantially higher uptake in parenchyma of young (6 months) transgenic AD mice compared to age-matched wild-type (WT) mice. Notably lower uptakes were observed in parenchyma and CSF of old (16 months) AD mice. Both young and old AD mice had an obviously slower CSF clearance than age-matched WT mice. This resembles recent reports of the hampered CSF clearance that leads to protein accumulation in the brain. These findings suggest that DGE MRI can identify altered glucose uptake and clearance in young AD mice upon the emergence of amyloid plaques. DGE MRI of brain parenchyma and CSF has potential for early AD stratification, especially at 3T clinical field strength MRI.
  •  
3.
  • Knutsson, Linda, et al. (författare)
  • Dynamic Susceptibility Contrast MRI at 7 T:Tail-Scaling Analysis and Inferences About Field Strength Dependence
  • 2017
  • Ingår i: Tomography : a journal for imaging research. - : MDPI AG. - 2379-1381. ; 3:2, s. 8-74
  • Tidskriftsartikel (refereegranskat)abstract
    • Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) following bolus injection of gadolinium contrast agent (CA) is widely used for the estimation of brain perfusion parameters such as cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) for both clinical and research purposes. Although it is predicted that DSC-MRI will have superior performance at high magnetic field strengths, to the best of our knowledge, there are no reports of 7 T DSC-MRI in the literature. It is plausible that the transfer of DSC-MRI to 7 T may be accompanied by increased R2* relaxivity in tissue and a larger difference in ΔR2*-versus-concentration relationships between tissue and large vessels. If not accounted for, this will subsequently result in apparent CBV and CBF estimates that are higher than those reported previously at lower field strengths. The aims of this study were therefore to assess the feasibility of 7 T DSC-MRI and to investigate the apparent field-strength dependence of CBV and CBF estimates. In total, 8 healthy volunteers were examined using DSC-MRI at 7 T. A reduced CA dose of 0.05 mmol/kg was administered to decrease susceptibility artifacts. CBV, CBF, and MTT maps were calculated using standard DSC-MRI tracer-kinetic theory. Subject-specific arterial partial volume correction factors were obtained using a tail-scaling approach. Compared with literature values obtained using the tail-scaling approach at 1.5 T and 3 T, the CBV and CBF values of the present study were found to be further overestimated. This observation is potentially related to an inferred field-strength dependence of transverse relaxivities, although issues related to the CA dose must also be considered.
  •  
4.
  • Seidemo, Anina, et al. (författare)
  • Towards robust glucose chemical exchange saturation transfer imaging in humans at 3 T: Arterial input function measurements and the effects of infusion time
  • 2022
  • Ingår i: NMR in Biomedicine. - : Wiley. - 0952-3480 .- 1099-1492. ; 35:2, s. 4624-4624
  • Tidskriftsartikel (refereegranskat)abstract
    • Dynamic glucose-enhanced (DGE) magnetic resonance imaging (MRI) has shown potential for tumor imaging using D-glucose as a biodegradable contrast agent. The DGE signal change is small at 3 T (around 1 and accurate detection is hampered by motion. The intravenous D-glucose injection is associated with transient side effects that can indirectly generate subject movements. In this study, the aim was to study DGE arterial input functions (AIFs) in healthy volunteers at 3 T for different scanning protocols, as a step towards making the glucose chemical exchange saturation transfer (glucoCEST) protocol more robust. Two different infusion durations (1.5 and 4.0 min) and saturation frequency offsets (1.2 and 2.0 ppm) were used. The effect of subject motion on the DGE signal was studied by using motion estimates retrieved from standard retrospective motion correction to create pseudo-DGE maps, where the apparent DGE signal changes were entirely caused by motion. Furthermore, the DGE AIFs were compared with venous blood glucose levels. A significant difference (p = 0.03) between arterial baseline and postinfusion DGE signal was found after D-glucose infusion. The results indicate that the measured DGE AIF signal change depends on both motion and blood glucose concentration change, emphasizing the need for sufficient motion correction in glucoCEST imaging. Finally, we conclude that a longer infusion duration (e.g. 3–4 min) should preferably be used in glucoCEST experiments, because it can minimize the glucose infusion side effects without negatively affecting the DGE signal change.
  •  
5.
  • Zhou, Jinyuan, et al. (författare)
  • Review and consensus recommendations on clinical APT-weighted imaging approaches at 3T : Application to brain tumors
  • 2022
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 88:2, s. 546-574
  • Tidskriftsartikel (refereegranskat)abstract
    • Amide proton transfer-weighted (APTw) MR imaging shows promise as a biomarker of brain tumor status. Currently used APTw MRI pulse sequences and protocols vary substantially among different institutes, and there are no agreed-on standards in the imaging community. Therefore, the results acquired from different research centers are difficult to compare, which hampers uniform clinical application and interpretation. This paper reviews current clinical APTw imaging approaches and provides a rationale for optimized APTw brain tumor imaging at 3 T, including specific recommendations for pulse sequences, acquisition protocols, and data processing methods. We expect that these consensus recommendations will become the first broadly accepted guidelines for APTw imaging of brain tumors on 3 T MRI systems from different vendors. This will allow more medical centers to use the same or comparable APTw MRI techniques for the detection, characterization, and monitoring of brain tumors, enabling multi-center trials in larger patient cohorts and, ultimately, routine clinical use.
  •  
6.
  • Lehmann, Patrick M, et al. (författare)
  • A numerical human brain phantom for dynamic glucose-enhanced (DGE) MRI : On the influence of head motion at 3T
  • 2023
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 89:5, s. 1871-1887
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Dynamic glucose-enhanced (DGE) MRI relates to a group of exchange-based MRI techniques where the uptake of glucose analogues is studied dynamically. However, motion artifacts can be mistaken for true DGE effects, while motion correction may alter true signal effects. The aim was to design a numerical human brain phantom to simulate a realistic DGE MRI protocol at 3T that can be used to assess the influence of head movement on the signal before and after retrospective motion correction.METHODS: MPRAGE data from a tumor patient were used to simulate dynamic Z-spectra under the influence of motion. The DGE responses for different tissue types were simulated, creating a ground truth. Rigid head movement patterns were applied as well as physiological dilatation and pulsation of the lateral ventricles and head-motion-induced B 0 -changes in presence of first-order shimming. The effect of retrospective motion correction was evaluated. RESULTS: Motion artifacts similar to those previously reported for in vivo DGE data could be reproduced. Head movement of 1 mm translation and 1.5 degrees rotation led to a pseudo-DGE effect on the order of 1% signal change. B 0 effects due to head motion altered DGE changes due to a shift in the water saturation spectrum. Pseudo DGE effects were partly reduced or enhanced by rigid motion correction depending on tissue location. CONCLUSION: DGE MRI studies can be corrupted by motion artifacts. Designing post-processing methods using retrospective motion correction including B 0 correction will be crucial for clinical implementation. The proposed phantom should be useful for evaluation and optimization of such techniques.
  •  
7.
  • Seidemo, Anina, et al. (författare)
  • Tissue response curve shape analysis of dynamic glucose enhanced (DGE) and dynamic contrast enhanced (DCE) MRI in patients with brain tumor
  • 2023
  • Ingår i: NMR in Biomedicine. - : Wiley. - 0952-3480 .- 1099-1492. ; 36:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Dynamic glucose enhanced (DGE) MRI is used to study the signal intensity time course (tissue response curve) after D-glucose injection. D-glucose has potential as a biodegradable alternative or complement to gadolinium-based contrast agents, with DGE being comparable to dynamic contrast enhanced (DCE) MRI. However, the tissue uptake kinetics as well as the detection methods of DGE differ from DCE, and it is relevant to compare these techniques in terms of spatiotemporal enhancement patterns. This study aims to develop a DGE analysis method based on tissue response curve shapes, and to investigate whether DGE MRI provides similar or complementary information to DCE MRI. Eleven patients with suspected gliomas were studied. Tissue response curves were measured for DGE and DCE MRI at 7 tesla and the area under curve (AUC) was assessed. Seven types of response curve shapes were postulated and subsequently identified by deep learning to create color-coded “curve maps” showing the spatial distribution of different curve types. DGE AUC values were significantly higher in lesions than in normal tissue (p
  •  
8.
  • van Zijl, Peter C. M., et al. (författare)
  • Hyperpolarized MRI, functional MRI, MR spectroscopy and CEST to provide metabolic information in vivo
  • 2021
  • Ingår i: Current Opinion in Chemical Biology. - : Elsevier BV. - 1367-5931. ; 63, s. 209-218
  • Tidskriftsartikel (refereegranskat)abstract
    • Access to metabolic information in vivo using magnetic resonance (MR) technologies has generally been the niche of MR spectroscopy (MRS) and spectroscopic imaging (MRSI). Metabolic fluxes can be studied using the infusion of substrates labeled with magnetic isotopes, with the use of hyperpolarization especially powerful. Unfortunately, these promising methods are not yet accepted clinically, where fast, simple, and reliable measurement and diagnosis are key. Recent advances in functional MRI and chemical exchange saturation transfer (CEST) MRI allow the use of water imaging to study oxygen metabolism and tissue metabolite levels. These, together with the use of novel data analysis approaches such as machine learning for all of these metabolic MR approaches, are increasing the likelihood of their clinical translation.
  •  
9.
  • Xu, Xiang, et al. (författare)
  • d-glucose weighted chemical exchange saturation transfer (glucoCEST)-based dynamic glucose enhanced (DGE) MRI at 3T : early experience in healthy volunteers and brain tumor patients
  • 2020
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 84:1, s. 247-262
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Dynamic glucose enhanced (DGE) MRI has shown potential for imaging glucose delivery and blood-brain barrier permeability at fields of 7T and higher. Here, we evaluated issues involved with translating d-glucose weighted chemical exchange saturation transfer (glucoCEST) experiments to the clinical field strength of 3T.METHODS: Exchange rates of the different hydroxyl proton pools and the field-dependent T2 relaxivity of water in d-glucose solution were used to simulate the water saturation spectra (Z-spectra) and DGE signal differences as a function of static field strength B0 , radiofrequency field strength B1 , and saturation time tsat . Multislice DGE experiments were performed at 3T on 5 healthy volunteers and 3 glioma patients.RESULTS: Simulations showed that DGE signal decreases with B0 , because of decreased contributions of glucoCEST and transverse relaxivity, as well as coalescence of the hydroxyl and water proton signals in the Z-spectrum. At 3T, because of this coalescence and increased interference of direct water saturation and magnetization transfer contrast, the DGE effect can be assessed over a broad range of saturation frequencies. Multislice DGE experiments were performed in vivo using a B1 of 1.6 µT and a tsat of 1 second, leading to a small glucoCEST DGE effect at an offset frequency of 2 ppm from the water resonance. Motion correction was essential to detect DGE effects reliably.CONCLUSION: Multislice glucoCEST-based DGE experiments can be performed at 3T with sufficient temporal resolution. However, the effects are small and prone to motion influence. Therefore, motion correction should be used when performing DGE experiments at clinical field strengths.
  •  
10.
  • Xu, Xiang, et al. (författare)
  • Dynamic Glucose-Enhanced (DGE) MRI: Translation to Human Scanning and First Results in Glioma Patients.
  • 2015
  • Ingår i: Tomography : a journal for imaging research. - : MDPI AG. - 2379-1381. ; 1:2, s. 105-114
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent animal studies have shown that D-glucose is a potential biodegradable MRI contrast agent for imaging glucose uptake in tumors. Here, we show the first translation of that use of D-glucose to human studies. Chemical exchange saturation transfer (CEST) MRI at a single frequency offset optimized for detection of hydroxyl protons in D-glucose (glucoCEST) was used to image dynamic signal changes in the human brain at 7T during and after infusion of D-glucose. Dynamic glucose-enhanced (DGE) image data from four normal volunteers and three glioma patients showed strong signal enhancement in blood vessels, while the enhancement varied spatially over the tumor. Areas of enhancement differed spatially between DGE and conventional Gd-enhanced imaging, suggesting complementary image information content for these two types of agents. In addition, different tumor areas enhanced with D-glucose at different times post-infusion, suggesting a sensitivity to perfusion-related properties such as substrate delivery and blood-brain barrier (BBB) permeability. These preliminary results suggest that DGE MRI is feasible to study glucose uptake in humans, providing a time-dependent set of data that contains information regarding arterial input function (AIF), tissue perfusion, glucose transport across the BBB and cell membrane, and glucose metabolism.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 20

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy