SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(van der Molen Aart J.) "

Sökning: WFRF:(van der Molen Aart J.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dahlman, Pär, et al. (författare)
  • How Much Dose Can Be Saved in Three-Phase CT Urography? A Combination of Normal-Dose Corticomedullary Phase With Low-Dose Unenhanced and Excretory Phases
  • 2012
  • Ingår i: American Journal of Roentgenology. - 0361-803X .- 1546-3141. ; 199:4, s. 852-860
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE:The purpose of this study was to investigate the degree to which the total radiation dose for CT urography can be lowered by selective reduction of the dose in the unenhanced and excretory phases when images in these phases are systematically evaluated alongside normal-dose corticomedullary phase images.SUBJECTS AND METHODS:Twenty-seven patients (mean age, 74 ± 9 years) underwent single-bolus CT urography with acquisition in the unenhanced, corticomedullary, and 5-minute excretory phases. The scanning parameters for normal-dose CT urography were as follows: 16 × 0.75 mm, 120 kV, and automatic exposure control technique reference tube loads of 100, 120, and 100 effective mAs (mAseff). The patients also underwent low-dose unenhanced and excretory phase scanning, in which the dose was escalated stepwise from a volume CT dose index (CTDIvol) of 1.7 to 6.6 mGy (reference 20-40-60-80 mAseff). Images were analyzed for quality and diagnostic confidence. If low-dose scans of three patients were inadequate, the study continued to the next dose level. When 20 patients were successfully included in the unenhanced and excretory phase groups, the study ended. Doses were calculated with a CT patient dosimetry calculator.RESULTS:Combined with the normal dose for corticomedullary phase scanning, doses of CTDIvol 1.5 mGy for the unenhanced phase and CTDIvol 2.7 mGy for the excretory phase were sufficient. The effective dose for three-phase CT urography was lowered from 16.2 to 9.4 mSv, a decrease of 42%. Diagnostic confidence in low-dose images was equal to that in normal-dose images when low-dose unenhanced and excretory phase images were read along-side normal-dose corticomedullary phase images.CONCLUSION:With a three-phase CT urographic protocol, significant dose reductions in the unenhanced and excretory phases can be achieved when these phases are combined with a normal-dose corticomedullary phase.
  •  
2.
  • Morcos, Sameh K., et al. (författare)
  • Reducing the risk of iodine-based and MRI contrast media administration : recommendation for a questionnaire at the time of booking
  • 2008
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X .- 1872-7727. ; 66:2, s. 225-229
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a practical questionnaire to be used when a contrast medium examination is requested. The questionnaire is based on the guidelines from the European Society of Urogenital Radiology. Its aim is to identify patients at increased risk of clinically relevant renal and non-renal adverse reactions to iodine-based and MRI contrast agents. The questionnaire should be completed by the referring physician when the examination is requested.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy