SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Equipment Engineering) "

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Equipment Engineering)

  • Resultat 1-10 av 300
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ortiz Catalan, Max Jair, 1982, et al. (författare)
  • Patterned Stimulation of Peripheral Nerves Produces Natural Sensations With Regards to Location but Not Quality
  • 2019
  • Ingår i: IEEE Transactions on Medical Robotics and Bionics. - 2576-3202. ; 1:3, s. 199-203
  • Tidskriftsartikel (refereegranskat)abstract
    • Sensory feedback is crucial for dexterous manipulation and sense of ownership. Electrical stimulation of severed afferent fibers due to an amputation elicits referred sensations in the missing limb. However, these sensations are commonly reported with a concurrent “electric” or “tingling” character (paresthesia). In this paper, we examined the effect of modulating different pulse parameters on the quality of perceived sensations. Three subjects with above-elbow amputation were implanted with cuff electrodes and stimulated with a train of pulses modulated in either amplitude, width, or frequency (“patterned stimulation”). Pulses were shaped using a slower carrier wave or via quasi-random generation. Subjects were asked to evaluate the natural quality of the resulting sensations using a numeric rating scale. We found that the location of the percepts was distally referred and somatotopically congruent, but their quality remained largely perceived as artificial despite employing patterned modulation. Sensations perceived as arising from the missing limb are intuitive and natural with respect to their location and, therefore, useful for functional restoration. However, our results indicate that sensory transformation from paresthesia to natural qualia seems to require more than patterned stimulation.
  •  
2.
  • Rezaei Aghdam, Sina, 1989, et al. (författare)
  • Reducing Motion Artifacts in Microwave-Based Hemorrhagic Stroke Detection
  • 2019
  • Ingår i: 13th European Conference on Antennas and Propagation, EuCAP 2019.
  • Konferensbidrag (refereegranskat)abstract
    • The use of microwave technology for brain stroke detection opens up the opportunity for developing low-cost transportable devices which can be employed for rapid and prehospital detection of bleeding in patients with traumatic brain injury. Since the detection relies on changes in the scattering parameters of the tissues during pathological conditions, the movements in head or the antennas can deteriorate the detection accuracy. As a countermeasure to this problem, we introduce a technique for reducing the sensitivity of the detection system to motion artifacts. Via analyzing the scattering from an anatomically accurate model of human brain, we evidence that the channels between different pairs of antennas exhibit significantly different levels of sensitivity to the movement. Using this as a ground truth, we develop a generalized singular value decomposition (GSVD)-based approach for assigning appropriate weights to the channels between different antennas such that the probability of correct bleeding detection is maximized.
  •  
3.
  • Rowa, Per, et al. (författare)
  • Automated Malaria Parasite Detection
  • 1977
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • A system for malaria parasite detection in thin blood-smears is presented. Sample slides prepared with standard methods are accepted. A low-cost TV-camera mounted on an ordinary microscope with a computer controlled stage is used as a picture sensor. Frames, digitized in windows of 64 x 64 pixels are fed into a special purpose picture processor at normal frame rate (25 frames/sec). In the picture processor measurements are made on the images at high speed. The classification problem is split into different levels each having different characteristics such as different sampling density. Four classes, three of which are different types of malaria parasites, are recognized. As a whole the classification is best labelled as a sequential pattern recognition procedure.In its preliminary version the system has been run at a speed comparable to that of a human operator, that is l 500 cells per minute. A test on 80 000 cells gave 25 false negatives out of 283 parasites (9%) and 41 false positives (0.05%).
  •  
4.
  • Tomasic, Ivan, et al. (författare)
  • Comparison of publicly available beat detection algorithms performances on the ECGs obtained by a patch ECG device
  • 2019
  • Ingår i: 2019 42nd International Convention on Information and Communication Technology, Electronics and Microelectronics, MIPRO 2019 - Proceedings. - : Institute of Electrical and Electronics Engineers Inc.. - 9789532330984 ; , s. 275-278
  • Konferensbidrag (refereegranskat)abstract
    • Eight ECG beat detection algorithms, from the PhysioNet's WFDB and Cardiovascular Signal toolboxes, were tested on twenty measurements, obtained by the Savvy patch ECG device, for their accuracy in beat detection. On each subject, one measurement is obtained while sitting and one while running. Each measurement lasted from thirty seconds to one minute. The measurements obtained while running were more challenging for all the algorithms, as most of them almost perfectly detected all the beats on the measurements obtained in sitting position. However, when applied on the measurements obtained while running, all the algorithms have performed with decreased accuracy. Considering overall percentage of the faulty detected peaks, the four best algorithms were jqrs, from the Cardiovascular Signal Toolbox, and ecgpuwave, gqrs, and wqrs, from the WFDB Toolbox, with percentages of faulty detected beats 1.7, 2.3, 2.9, and 3, respectively. 
  •  
5.
  • Zeng, Xuezhi, 1980, et al. (författare)
  • Investigation of an ultra wideband noise sensor for health monitoring
  • 2020
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 20:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Quick on-scene assessment and early intervention is the key to reduce the mortality of stroke and trauma patients, and it is highly desirable to develop ambulance-based diagnostic and monitoring devices in order to provide additional support to the medical personnel. We developed a compact and low cost ultra wideband noise sensor for medical diagnostics and vital sign monitoring in pre-hospital settings. In this work, we demonstrated the functionality of the sensor for respiration and heartbeat monitoring. In the test, metronome was used to manipulate the breathing pattern and the heartbeat rate reference was obtained with a commercial electrocardiogram (ECG) device. With seventeen tests performed for respiration rate detection, sixteen of them were successfully detected. The results also show that it is possible to detect the heartbeat rate accurately with the developed sensor.
  •  
6.
  • Khodadad, Davood, 1985-, et al. (författare)
  • Optimized breath detection algorithm in electrical impedance tomography
  • 2018
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 39:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: This paper defines a method for optimizing the breath delineation algorithms used in electrical impedance tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern.Approach: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project.Main results: Three different algorithms are proposed that improve the breath detector performance by adding conditions on (1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, (2) minimum tidal impedance amplitude and (3) minimum tidal breath rate obtained from time-frequency analysis. As a baseline a zero-crossing algorithm has been used with some default parameters based on the Swisstom EIT device.Significance: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the receiver operating characterics. This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.
  •  
7.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • In search of the optimal ultrasound heart perfusion imaging platform
  • 2015
  • Ingår i: Journal of ultrasound in medicine. - : Wiley. - 0278-4297 .- 1550-9613. ; 34:9, s. 1599-1605
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveQuantification of the myocardial perfusion by contrast echocardiography (CEC) remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled.MethodsTo contribute towards an improvement, we developed a CEC perfusion imaging platform based on isolated rat heart coupled to the ultrasound scanner. Perfusion was assessed using three different types of contrast agent: dextran-based Promiten®, phospholipid-shelled SonoVue®, and polymer-shelled MB-pH5-RT. The myocardial video-intensity was monitored over time from contrast administration to peak and two characteristic constants were calculated using exponential fit (A representing capillary volume and b representing inflow velocity).ResultsAcquired experimental evidence demonstrates that the application of all three types of contrast agent allow ultrasonic estimation of myocardial perfusion in the isolated rat heart. Video-intensity maps show that an increase in contrast concentration increases the late plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to Axb, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by the flowmeter attached to the aortic cannula.ConclusionsThe described CEC perfusion imaging platform holds promise for standardized evaluation and optimization of ultrasound contrast perfusion imaging where real time inflow curves at low acoustic power semi-quantitatively reflect coronary flow.
  •  
8.
  • Kothapalli, Veera Venkata Satya Naray, 1985-, et al. (författare)
  • Unique pumping-out fracturing mechanism of a polymer-shelled contrast agent : An acoustic characterization and optical visualization
  • 2014
  • Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 62:3, s. 451-462
  • Tidskriftsartikel (refereegranskat)abstract
    • This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.
  •  
9.
  • Boyraz Baykas, Pinar, 1981, et al. (författare)
  • Design of a Low-cost Tactile Robotic Sleeve for Autonomous Endoscopes and Catheters
  • 2020
  • Ingår i: Measurement and Control. - : SAGE Publications. - 0020-2940. ; 53:3-4, s. 613-626
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent developments in medical robotics have been significant, supporting the minimally invasive operation requirements, such as smaller devices and more feedback available to surgeons. Nevertheless, the tactile feedback from a catheter or endoscopic type robotic device has been restricted mostly on the tip of the device and was not aimed to support the autonomous movement of the medical device during operation. In this work, we design a robotic sheath/sleeve with a novel and more comprehensive approach, which can function for whole-body or segment-based feedback control as well as diagnostic purposes. The robotic sleeve has several types of piezo-resistive pressure and extension sensors, which are embedded at several latitudes and depths of the silicone substrate. The sleeve takes the human skin as a biological model for its structure. It has a better tactile sensation of the inner tissues in the torturous narrow channels such as cardiovascular or endo-luminal tracts in human body thus can be used to diagnose abnormalities. In addition to this capability, using the stretch sensors distributed alongside its body, the robotic sheath/sleeve can perceive the ego-motion of the robotic backbone of the catheter and can act as a position feedback device. Because of the silicone substrate, the sleeve contributes toward safety of the medical device passively by providing a compliant interface. As an active safety measure, the robotic sheath can sense blood-clots or sudden turns inside a channel and by modifying the local trajectory, and can prevent embolisms or tissue rupture. In the future, advanced manufacturing techniques will increase the capabilities of the tactile robotic sleeve.
  •  
10.
  • Böhler, Christian, et al. (författare)
  • Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants
  • 2023
  • Ingår i: Advanced Science. - : John Wiley & Sons. - 2198-3844. ; 10:14
  • Tidskriftsartikel (refereegranskat)abstract
    • Flexible implantable neurointerfaces show great promise in addressing one of the major challenges of implantable neurotechnology, namely the loss of signal connected to unfavorable probe tissue interaction. The authors here show how multilayer polyimide probes allow high-density intracortical recordings to be combined with a reliable long-term stable tissue interface, thereby progressing toward chronic stability of implantable neurotechnology. The probes could record 10–60 single units over 5 months with a consistent peak-to-peak voltage at dimensions that ensure robust handling and insulation longevity. Probes that remain in intimate contact with the signaling tissue over months to years are a game changer for neuroscience and, importantly, open up for broader clinical translation of systems relying on neurotechnology to interface the human brain.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 300
Typ av publikation
tidskriftsartikel (136)
konferensbidrag (80)
patent (31)
doktorsavhandling (23)
bokkapitel (9)
licentiatavhandling (7)
visa fler...
annan publikation (6)
forskningsöversikt (6)
konstnärligt arbete (2)
rapport (2)
visa färre...
Typ av innehåll
refereegranskat (204)
övrigt vetenskapligt/konstnärligt (69)
populärvet., debatt m.m. (27)
Författare/redaktör
Danielsson, Mats, Pr ... (26)
Persson, Mikael, 195 ... (15)
Dobsicek Trefna, Han ... (15)
Augustine, Robin, 19 ... (14)
Roxhed, Niclas (7)
Danielsson, Mats (7)
visa fler...
Håkansson, Bo, 1953 (7)
Cubo, Rubén (6)
Medvedev, Alexander (5)
Lundh, Torbjörn, 196 ... (5)
van der Wijngaart, W ... (5)
Stemme, Göran, 1958 (5)
Brodin, Lars-Åke (5)
Danielsson, Mats, 19 ... (5)
Reinfeldt, Sabine, 1 ... (5)
Bjällmark, Anna (5)
Persson, Mats, 1987- (5)
Johansson, Anders (4)
Seoane, Fernando, 19 ... (4)
Janerot-Sjöberg, Bir ... (4)
Bornefalk, Hans (4)
Antfolk, Christian (4)
Candefjord, Stefan, ... (4)
Cederström, Björn (4)
Haj-Hosseini, Neda, ... (4)
Åström, Mattias (4)
Grönberg, Fredrik (4)
Behnke, O. (3)
Bargassa, P (3)
Ortiz Catalan, Max J ... (3)
Blanc, F. (3)
Steen, Stig (3)
Seoane, Fernando (3)
Soltesz, Kristian (3)
Larsson, M (3)
Höglund, Odd (3)
Bertin, V. (3)
Karlsson, Staffan (3)
Aslanides, E. (3)
Mastinu, Enzo, 1987 (3)
Holmin, Staffan (3)
McKelvey, Tomas, 196 ... (3)
Holmer, Mattias (3)
Magnusson, Charlotte (3)
Lammi, Mikko, 1961- (3)
Apostolakis, A. (3)
Benelli, A. (3)
Perez, Mauricio D. (3)
Monteith, Albert, 19 ... (3)
Möller, Sebastian (3)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (100)
Chalmers tekniska högskola (79)
Lunds universitet (45)
Uppsala universitet (34)
Linköpings universitet (22)
Karolinska Institutet (17)
visa fler...
Göteborgs universitet (16)
Umeå universitet (16)
Jönköping University (8)
Högskolan i Borås (6)
RISE (5)
Linnéuniversitetet (4)
Sveriges Lantbruksuniversitet (4)
Högskolan i Halmstad (2)
Stockholms universitet (2)
Örebro universitet (2)
Malmö universitet (2)
Luleå tekniska universitet (1)
Mälardalens universitet (1)
Gymnastik- och idrottshögskolan (1)
Högskolan Dalarna (1)
Blekinge Tekniska Högskola (1)
visa färre...
Språk
Engelska (296)
Svenska (2)
Odefinierat språk (1)
Japanska (1)
Forskningsämne (UKÄ/SCB)
Teknik (300)
Medicin och hälsovetenskap (81)
Naturvetenskap (32)
Lantbruksvetenskap (2)
Samhällsvetenskap (2)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy