SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Image Processing) "

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Image Processing)

  • Resultat 1-10 av 1701
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abbaspour, S., et al. (författare)
  • Real-Time and Offline Evaluation of Myoelectric Pattern Recognition for the Decoding of Hand Movements
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Pattern recognition algorithms have been widely used to map surface electromyographic signals to target movements as a source for prosthetic control. However, most investigations have been conducted offline by performing the analysis on pre-recorded datasets. While real-time data analysis (i.e., classification when new data becomes available, with limits on latency under 200-300 milliseconds) plays an important role in the control of prosthetics, less knowledge has been gained with respect to real-time performance. Recent literature has underscored the differences between offline classification accuracy, the most common performance metric, and the usability of upper limb prostheses. Therefore, a comparative offline and real-time performance analysis between common algorithms had yet to be performed. In this study, we investigated the offline and real-time performance of nine different classification algorithms, decoding ten individual hand and wrist movements. Surface myoelectric signals were recorded from fifteen able-bodied subjects while performing the ten movements. The offline decoding demonstrated that linear discriminant analysis (LDA) and maximum likelihood estimation (MLE) significantly (p < 0.05) outperformed other classifiers, with an average classification accuracy of above 97%. On the other hand, the real-time investigation revealed that, in addition to the LDA and MLE, multilayer perceptron also outperformed the other algorithms and achieved a classification accuracy and completion rate of above 68% and 69%, respectively.
  •  
2.
  • Bondesson, Johan, 1991, et al. (författare)
  • Definition of Tubular Anatomic Structures from Arbitrary Stereo Lithographic Surface
  • 2017
  • Ingår i: Initiative Seminar Engineering Health, 8-9 November 2017, Chalmers.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • An accurate description of anatomies and dynamics of vessels is crucial to understand their characteristics and improve surgical techniques, thus it is the basis, in addition to surgeon experience, on which stent design and operation procedures rely. The process of producing this description is user intensive, and recent improvement in image processing of medical3D imaging allows for a more automated workflow. However, there is a need to bridge the gap from a processed geometry to a robust mathematical computational grid. By sequentially segmenting a tubular anatomic structure, here defined by a stereo lithographic (STL) surface, an initial centerline is formed by connecting centroids of orthogonal cross-sectional contours along the length of the structure. Relying on the initial centerline, a set of non-overlapping 2D cross sectional contours are defined along the centerline, a centerline which is updated after the 2D contours are produced. After a second iteration of producing 2D contours and updating the centerline, a full description of the structure is created. Our method for describing vessel geometry shows good coherence to existing method. The main advantages of our method include the possibility of having arbitrary triangulated STL surface input, automated centerline definition, safety against intersecting cross-sectional contours and automatic clean-up of local kinks and wrinkles.
  •  
3.
  • Lui, Hoi-Shun, et al. (författare)
  • On the matching medium for microwave stroke diagnosis
  • 2019
  • Ingår i: Biomedical Physics and Engineering Express. - : IOP Publishing. - 2057-1976. ; 5:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The choice of matching medium can directly affect the amount of power transmitted into and through human bodies, which impacts on the quality of the reconstructed images in microwave-based medical imaging, and thus the diagnosis accuracies. In this paper, the amount of the transmitted and reflected power of multi-layer planar healthy and hemorrhagic stroke brain models under different choices of matching medium are determined. These multi-layer planar brain tissue models are made up of at least 17 tissue layers with realistic dielectric properties. A layer of blood with different thickness is introduced to model the case of hemorrhagic stroke. Our results show that matching medium with low relative permittivity provides better intrinsic contrast between healthy brain and hemorrhagic brain. Analysis on how the reflection coefficient and transmittance vary under different matching medium are included to provide better insights to the findings.
  •  
4.
  • Khodadad, Davood, 1985-, et al. (författare)
  • Optimized breath detection algorithm in electrical impedance tomography
  • 2018
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 39:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: This paper defines a method for optimizing the breath delineation algorithms used in electrical impedance tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern.Approach: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project.Main results: Three different algorithms are proposed that improve the breath detector performance by adding conditions on (1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, (2) minimum tidal impedance amplitude and (3) minimum tidal breath rate obtained from time-frequency analysis. As a baseline a zero-crossing algorithm has been used with some default parameters based on the Swisstom EIT device.Significance: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the receiver operating characterics. This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.
  •  
5.
  • Y Banaem, Hossein, et al. (författare)
  • Brain tumor modeling : glioma growth and interaction with chemotherapy
  • 2011
  • Ingår i: International Conference on Graphic and Image Processing (ICGIP 2011). - : SPIE. ; 8285
  • Konferensbidrag (refereegranskat)abstract
    • In last decade increasingly mathematical models of tumor growths have been studied, particularly on solid tumors which growth mainly caused by cellular proliferation. In this paper we propose a modified model to simulate the growth of gliomas in different stages. Glioma growth is modeled by a reaction-advection-diffusion. We begin with a model of untreated gliomas and continue with models of polyclonal glioma following chemotherapy. From relatively simple assumptions involving homogeneous brain tissue bounded by a few gross anatomical landmarks (ventricles and skull) the models have been expanded to include heterogeneous brain tissue with different motilities of glioma cells in grey and white matter. Tumor growth is characterized by a dangerous change in the control mechanisms, which normally maintain a balance between the rate of proliferation and the rate of apoptosis (controlled cell death). Result shows that this model closes to clinical finding and can simulate brain tumor behavior properly.
  •  
6.
  • Isaksson-Daun, Johan (författare)
  • A Sound Approach Toward a Mobility Aid for Blind and Low-Vision Individuals
  • 2023
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Reduced independent mobility of blind and low-vision individuals (BLVIs) cause considerable societal cost, burden on relatives, and reduced quality of life for the individuals, including increased anxiety, depression symptoms, need of assistance, risk of falls, and mortality. Despite the numerous electronic travel aids proposed since at least the 1940’s, along with ever-advancing technology, the mobility issues persist. A substantial reason for this is likely several and severe shortcomings of the field, both in regards to aid design and evaluation.In this work, these shortcomings are addressed with a generic design model called Desire of Use (DoU), which describes the desire of a given user to use an aid for a given activity. It is then applied on mobility of BLVIs (DoU-MoB), to systematically illuminate and structure possibly all related aspects that such an aid needs to aptly deal with, in order for it to become an adequate aid for the objective. These aspects can then both guide user-centered design as well as choice of test methods and measures.One such measure is then demonstrated in the Desire of Use Questionnaire for Mobility of Blind and Low-Vision Individuals (DoUQ-MoB), an aid-agnostic and comprehensive patient-reported outcome measure. The question construction originates from the DoU-MoB to ensure an encompassing focus on mobility of BLVIs, something that has been missing in the field. Since it is aid-agnostic it facilitates aid comparison, which it also actively promotes. To support the reliability of the DoUQ-MoB, it utilizes the best known practices of questionnaire design and has been validated once with eight orientation and mobility professionals, and six BLVIs. Based on this, the questionnaire has also been revised once.To allow for relevant and reproducible methodology, another tool presented herein is a portable virtual reality (VR) system called the Parrot-VR. It uses a hybrid control scheme of absolute rotation by tracking the user’s head in reality, affording intuitive turning; and relative movement where simple button presses on a controller moves the virtual avatar forward and backward, allowing for large-scale traversal while not walking physically. VR provides excellent reproducibility, making various aggregate movement analysis feasible, while it is also inherently safe. Meanwhile, the portability of the system facilitates testing near the participants, substantially increasing the number of potential blind and low-vision recruits for user tests.The thesis also gives a short account on the state of long-term testing in the field; it being short is mainly due to that there is not much to report. It then provides an initial investigation into possible outcome measures for such tests by taking instruments in use by Swedish orientation and mobility professionals as a starting point. Two of these are also piloted in an initial single-session trial with 19 BLVIs, and could plausibly be used for long-term tests after further evaluation.Finally, a discussion is presented regarding the Audomni project — the development of a primary mobility aid for BLVIs. Audomni is a visuo-auditory sensory supplementation device, which aims to take visual information and translate it to sound. A wide field-of-view, 3D-depth camera records the environment, which is then transformed to audio through the sonification algorithms of Audomni, and finally presented in a pair of open-ear headphones that do not block out environmental sounds. The design of Audomni leverages the DoU-MoB to ensure user-centric development and evaluation, in the aim of reaching an aid with such form and function that it grants the users better mobility, while the users still want to use it.Audomni has been evaluated with user tests twice, once in pilot tests with two BLVIs, and once in VR with a heterogenous set of 19 BLVIs, utilizing the Parrot-VR and the DoUQ-MoB. 76 % of responders (13 / 17) answered that it was very or extremely likely that they would want use Audomni along with their current aid. This might be the first result in the field demonstrating a majority of blind and low-vision participants reporting that they actually want to use a new electronic travel aid. This shows promise that eventual long-term tests will demonstrate an increased mobility of blind and low-vision users — the overarching project aim. Such results would ultimately mean that Audomni can become an aid that alleviates societal cost, reduces burden on relatives, and improves users’ quality of life and independence.
  •  
7.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • In search of the optimal ultrasound heart perfusion imaging platform
  • 2015
  • Ingår i: Journal of ultrasound in medicine. - : Wiley. - 0278-4297 .- 1550-9613. ; 34:9, s. 1599-1605
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveQuantification of the myocardial perfusion by contrast echocardiography (CEC) remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled.MethodsTo contribute towards an improvement, we developed a CEC perfusion imaging platform based on isolated rat heart coupled to the ultrasound scanner. Perfusion was assessed using three different types of contrast agent: dextran-based Promiten®, phospholipid-shelled SonoVue®, and polymer-shelled MB-pH5-RT. The myocardial video-intensity was monitored over time from contrast administration to peak and two characteristic constants were calculated using exponential fit (A representing capillary volume and b representing inflow velocity).ResultsAcquired experimental evidence demonstrates that the application of all three types of contrast agent allow ultrasonic estimation of myocardial perfusion in the isolated rat heart. Video-intensity maps show that an increase in contrast concentration increases the late plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to Axb, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by the flowmeter attached to the aortic cannula.ConclusionsThe described CEC perfusion imaging platform holds promise for standardized evaluation and optimization of ultrasound contrast perfusion imaging where real time inflow curves at low acoustic power semi-quantitatively reflect coronary flow.
  •  
8.
  • Kothapalli, Veera Venkata Satya Naray, 1985-, et al. (författare)
  • Unique pumping-out fracturing mechanism of a polymer-shelled contrast agent : An acoustic characterization and optical visualization
  • 2014
  • Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 62:3, s. 451-462
  • Tidskriftsartikel (refereegranskat)abstract
    • This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.
  •  
9.
  • Borrelli, P., et al. (författare)
  • Artificial intelligence-aided CT segmentation for body composition analysis: a validation study
  • 2021
  • Ingår i: European Radiology Experimental. - : Springer Science and Business Media LLC. - 2509-9280. ; 5:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundBody composition is associated with survival outcome in oncological patients, but it is not routinely calculated. Manual segmentation of subcutaneous adipose tissue (SAT) and muscle is time-consuming and therefore limited to a single CT slice. Our goal was to develop an artificial-intelligence (AI)-based method for automated quantification of three-dimensional SAT and muscle volumes from CT images.MethodsEthical approvals from Gothenburg and Lund Universities were obtained. Convolutional neural networks were trained to segment SAT and muscle using manual segmentations on CT images from a training group of 50 patients. The method was applied to a separate test group of 74 cancer patients, who had two CT studies each with a median interval between the studies of 3days. Manual segmentations in a single CT slice were used for comparison. The accuracy was measured as overlap between the automated and manual segmentations.ResultsThe accuracy of the AI method was 0.96 for SAT and 0.94 for muscle. The average differences in volumes were significantly lower than the corresponding differences in areas in a single CT slice: 1.8% versus 5.0% (p <0.001) for SAT and 1.9% versus 3.9% (p < 0.001) for muscle. The 95% confidence intervals for predicted volumes in an individual subject from the corresponding single CT slice areas were in the order of 20%.Conclusions The AI-based tool for quantification of SAT and muscle volumes showed high accuracy and reproducibility and provided a body composition analysis that is more relevant than manual analysis of a single CT slice.
  •  
10.
  • Broman, Mikael, et al. (författare)
  • Recirculation during veno-venous extra-corporeal membrane oxygenation - a simulation study
  • 2015
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 38:1, s. 23-30
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Veno-venous ECMO is indicated in reversible life-threatening respiratory failure without life-threatening circulatory failure. Recirculation of oxygenated blood in the ECMO circuit decreases efficiency of patient oxygen delivery but is difficult to measure. We seek to identify and quantify some of the factors responsible for recirculation in a simulation model and compare with clinical data. Methods: A closed-loop real-time simulation model of the cardiovascular system has been developed. ECMO is simulated with a fixed flow pump 0 to 5 l/min with various cannulation sites -1) right atrium to inferior vena cava, 2) inferior vena cava to right atrium, and 3) superior+ inferior vena cava to right atrium. Simulations are compared to data from a retrospective cohort of 11 consecutive adult veno-venous ECMO patients in our department. Results: Recirculation increases with increasing ECMO-flow, decreases with increasing cardiac output, and is highly dependent on choice of cannulation sites. A more peripheral drainage site decreases recirculation substantially. Conclusions: Simulations suggest that recirculation is a significant clinical problem in veno-venous ECMO in agreement with clinical data. Due to the difficulties in measuring recirculation and interpretation of the venous oxygen saturation in the ECMO drainage blood, flow settings and cannula positioning should rather be optimized with help of arterial oxygenation parameters. Simulation may be useful in quantification and understanding of recirculation in VV-ECMO.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 1701
Typ av publikation
tidskriftsartikel (859)
konferensbidrag (621)
doktorsavhandling (85)
annan publikation (46)
bokkapitel (30)
forskningsöversikt (19)
visa fler...
rapport (16)
licentiatavhandling (12)
patent (10)
proceedings (redaktörskap) (2)
samlingsverk (redaktörskap) (1)
visa färre...
Typ av innehåll
refereegranskat (1324)
övrigt vetenskapligt/konstnärligt (366)
populärvet., debatt m.m. (9)
Författare/redaktör
Lindblad, Joakim (67)
Sladoje, Nataša (61)
Borga, Magnus (51)
Bengtsson, Ewert (45)
Wang, Chunliang, 198 ... (42)
Strand, Robin, 1978- (41)
visa fler...
Enqvist, Olof, 1981 (37)
Mehnert, Andrew, 196 ... (35)
Moreno, Rodrigo, 197 ... (35)
Knutsson, Hans (34)
Smedby, Örjan, Profe ... (34)
Sintorn, Ida-Maria (32)
Smedby, Örjan (31)
Romu, Thobias (31)
Frimmel, Hans (30)
Malmberg, Filip (29)
Helms, Gunther (28)
Wählby, Carolina (28)
Dahlqvist Leinhard, ... (26)
Trägårdh, Elin (25)
Eklund, Anders, 1981 ... (25)
Ulén, Johannes (25)
Kahl, Fredrik, 1972 (25)
Yu, Jun, 1962- (25)
Persson, Mats, 1987- (25)
Båth, Magnus, 1974 (23)
Smedby, Örjan, 1956- (22)
Dahlqvist Leinhard, ... (21)
Kullberg, Joel (21)
Wählby, Carolina, pr ... (21)
Nyström, Ingela (21)
Strand, Robin (20)
Edenbrandt, Lars, 19 ... (20)
Bjällmark, Anna (20)
Andersson, Mats (19)
Ebbers, Tino (19)
Wetzer, Elisabeth (19)
Gu, Irene Yu-Hua, 19 ... (18)
Larsson, Matilda (18)
Forsberg, Daniel (18)
Cinthio, Magnus (17)
Gustafsson, Agnetha, ... (17)
Månsson, Lars Gunnar ... (17)
Ahlström, Håkan (16)
Persson, Anders (16)
Ahlström, Håkan, 195 ... (15)
Kullberg, Joel, 1979 ... (14)
Grönlund, Christer (14)
Wang, Chunliang (14)
Dyverfeldt, Petter (14)
visa färre...
Lärosäte
Uppsala universitet (442)
Linköpings universitet (407)
Kungliga Tekniska Högskolan (286)
Lunds universitet (256)
Chalmers tekniska högskola (249)
Umeå universitet (121)
visa fler...
Göteborgs universitet (117)
Karolinska Institutet (92)
Sveriges Lantbruksuniversitet (34)
Örebro universitet (27)
Jönköping University (24)
Luleå tekniska universitet (21)
Linnéuniversitetet (17)
Högskolan i Halmstad (12)
Blekinge Tekniska Högskola (12)
Stockholms universitet (11)
RISE (10)
Mittuniversitetet (5)
Högskolan Dalarna (4)
Högskolan Väst (3)
Malmö universitet (3)
Högskolan i Gävle (2)
Mälardalens universitet (2)
Högskolan i Borås (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (1680)
Svenska (21)
Forskningsämne (UKÄ/SCB)
Teknik (1700)
Medicin och hälsovetenskap (513)
Naturvetenskap (419)
Samhällsvetenskap (10)
Lantbruksvetenskap (5)
Humaniora (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy