SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "AMNE:(TEKNIK OCH TEKNOLOGIER Medicinteknik Medicinsk apparatteknik) "

Sökning: AMNE:(TEKNIK OCH TEKNOLOGIER Medicinteknik Medicinsk apparatteknik)

  • Resultat 1-10 av 311
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Böhler, Christian, et al. (författare)
  • Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants
  • 2023
  • Ingår i: Advanced Science. - : John Wiley & Sons. - 2198-3844. ; 10:14
  • Tidskriftsartikel (refereegranskat)abstract
    • Flexible implantable neurointerfaces show great promise in addressing one of the major challenges of implantable neurotechnology, namely the loss of signal connected to unfavorable probe tissue interaction. The authors here show how multilayer polyimide probes allow high-density intracortical recordings to be combined with a reliable long-term stable tissue interface, thereby progressing toward chronic stability of implantable neurotechnology. The probes could record 10–60 single units over 5 months with a consistent peak-to-peak voltage at dimensions that ensure robust handling and insulation longevity. Probes that remain in intimate contact with the signaling tissue over months to years are a game changer for neuroscience and, importantly, open up for broader clinical translation of systems relying on neurotechnology to interface the human brain.
  •  
2.
  • Jing, Yujia, 1985 (författare)
  • Hyperthermia-responsive liposomal systems
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Abstract Sophisticated liposomal systems are emerging at an increasing rate to meet the demands for multifunctional drug carriers in chemotherapies in combined with hyperthermia. For example, liposomal drug carriers for temperature-controlled drug release under hyperthermic conditions have recently been tested in clinical trials. More advanced designs of liposomes are expected to release encapsulated contents and activate hidden surface-functions in response to heat stimulus. Towards this aim, the present thesis is focused on formulating asymmetric lipid systems that can preserve functional moieties, and reactivate the targeted function as well as release the encapsulated compounds upon local heating. The design of the asymmetric liposomal systems utilizes the heat-activated transmembrane lipid diffusion during gel to liquid-crystalline phase transitions of the lipid membranes.Rational design of advanced liposomal drug-delivery systems will require understanding of the physicochemical properties of lipid membranes under, e.g., hyperthermic conditions. Here, supported lipid membranes on planar solid surfaces were used for model studies of lipid composition yielding a gel to liquid crystalline phase-transition temperature in the range 40 – 45 °C. It was found that the liposome-to-membrane formation process is not only size-dependent but also governed by temperature. Two methods of preparing supported asymmetric lipid membranes were investigated. As a proof-of-concept, the upper leaflets were either replaced or chemically transformed by enzymatic hydrolysis. The processes were monitored using surface sensitive techniques such as quartz crystal microbalance with dissipation (QCM-D) and dual polarization interferometry (DPI). The asymmetric structures were stable at a room temperature, while lipid flip-flop was induced upon increasing of the temperature. Transmembrane lipid exchange in the asymmetric structure under hyperthermic conditions was demonstrated by detecting, through streptavidin binding, biotinylated lipids appearing at the top leaflet which were first located in the lower leaflet. The protocols developed for the supported lipid systems were adapted for the preparation of asymmetric liposomes. Biotinylated asymmetric liposomes were used as a model system to demonstrate the principle of heat-activated targeting of asymmetric liposomes to streptavidin-coated surfaces. More biologically relevant interaction was utilized to replace the biotin-streptavidin function, where asymmetric cationic liposomes were binding to anionic supported membrane immobilized surfaces upon heating. The described strategies for assembly of asymmetric supported membranes provide a guide to the development of multifunctional drug carriers. The protocols used in experiments with supported membranes were readily adapted to the preparation of asymmetric liposomes. The ongoing study tests the asymmetric liposomes in vitro, which is designed to demonstrate hyperthermia treatment can enhance accumulation of liposomes in FaDu cells, and at the same time activate release of the encapsulated components. The results of in vitro tests can be used to analyze the feasibility of utilizing the asymmetric liposomes as a platform in vivo to explore further improvement in their functions upon microwave hyperthermia.
  •  
3.
  • Xu, Cheng (författare)
  • A Segmented Silicon Strip Detector for Photon-Counting Spectral Computed Tomography
  • 2012
  • Konstnärligt arbete (övrigt vetenskapligt/konstnärligt)abstract
    • Spectral computed tomography with energy-resolving detectors has a potential to improve the detectability of images and correspondingly reduce the radiation dose to patients by extracting and properly using the energy information in the broad x-ray spectrum. A silicon photon-counting detector has been developed for spectral CT and it has successfully solved the problem of high photon flux in clinical CT applications by adopting the segmented detector structure and operating the detector in edge-on geometry. The detector was evaluated by both the simulation and measurements.The effects of energy loss and charge sharing on the energy response of this segmented silicon strip detector with different pixel sizes were investigated by Monte Carlo simulation and a comparison to pixelated CdTe detectors is presented. The validity of spherical approximations of initial charge cloud shape in silicon detectors was evaluated and a more accurate statistical model has been proposed.A photon-counting energy-resolving application specific integrated circuit (ASIC) developed for spectral CT was characterized extensively by electrical pulses, pulsed laser and real x-ray photons from both the synchrotron and an x-ray tube. It has been demonstrated that the ASIC performs as designed. A noise level of 1.09 keV RMS has been measured and a threshold dispersion of 0.89 keV RMS has been determined. The count rate performance of the ASIC in terms of count loss and energy resolution was evaluated by real x-rays and promising results have been obtained.The segmented silicon strip detector was evaluated using synchrotron radiation. An energy resolution of 16.1% has been determined with 22 keV photons in the lowest flux limit, which deteriorates to 21.5% at an input count rate of 100 Mcps mm−2. The fraction of charge shared events has been estimated and found to be 11.1% for 22 keV and 15.3% for 30 keV. A lower fraction of charge shared events and an improved energy resolution can be expected by applying a higher bias voltage to the detector.
  •  
4.
  • Rowa, Per, et al. (författare)
  • Automated Malaria Parasite Detection
  • 1977
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • A system for malaria parasite detection in thin blood-smears is presented. Sample slides prepared with standard methods are accepted. A low-cost TV-camera mounted on an ordinary microscope with a computer controlled stage is used as a picture sensor. Frames, digitized in windows of 64 x 64 pixels are fed into a special purpose picture processor at normal frame rate (25 frames/sec). In the picture processor measurements are made on the images at high speed. The classification problem is split into different levels each having different characteristics such as different sampling density. Four classes, three of which are different types of malaria parasites, are recognized. As a whole the classification is best labelled as a sequential pattern recognition procedure.In its preliminary version the system has been run at a speed comparable to that of a human operator, that is l 500 cells per minute. A test on 80 000 cells gave 25 false negatives out of 283 parasites (9%) and 41 false positives (0.05%).
  •  
5.
  • Ortiz Catalan, Max Jair, 1982, et al. (författare)
  • Patterned Stimulation of Peripheral Nerves Produces Natural Sensations With Regards to Location but Not Quality
  • 2019
  • Ingår i: IEEE Transactions on Medical Robotics and Bionics. - 2576-3202. ; 1:3, s. 199-203
  • Tidskriftsartikel (refereegranskat)abstract
    • Sensory feedback is crucial for dexterous manipulation and sense of ownership. Electrical stimulation of severed afferent fibers due to an amputation elicits referred sensations in the missing limb. However, these sensations are commonly reported with a concurrent “electric” or “tingling” character (paresthesia). In this paper, we examined the effect of modulating different pulse parameters on the quality of perceived sensations. Three subjects with above-elbow amputation were implanted with cuff electrodes and stimulated with a train of pulses modulated in either amplitude, width, or frequency (“patterned stimulation”). Pulses were shaped using a slower carrier wave or via quasi-random generation. Subjects were asked to evaluate the natural quality of the resulting sensations using a numeric rating scale. We found that the location of the percepts was distally referred and somatotopically congruent, but their quality remained largely perceived as artificial despite employing patterned modulation. Sensations perceived as arising from the missing limb are intuitive and natural with respect to their location and, therefore, useful for functional restoration. However, our results indicate that sensory transformation from paresthesia to natural qualia seems to require more than patterned stimulation.
  •  
6.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Electrical Bioimpedance Spectroscopy on Acute Unilateral Stroke Patients : Initial Observations regarding Differences between Sides
  • 2015
  • Ingår i: BioMed Research International. - : Hindawi Publishing Corporation. - 2314-6133 .- 2314-6141. ; 2015
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose. Electrical Bioimpedance Cerebral Monitoring is assessment in real time of health of brain tissue through study of passive dielectric properties of brain. During the last two decades theory and technology have been developed in parallel with animal experiments aiming to confirm feasibility of using bioimpedance-based technology for prompt detection of brain damage. Here, for the first time, we show that electrical bioimpedance measurements for left and right hemispheres are significantly different in acute cases of unilateral stroke within 24 hours from onset. Methods. Electrical BIS measurements have been taken in healthy volunteers and patients suffering from acute stroke within 24 hours of onset. BIS measurements have been obtained using SFB7 bioimpedance spectrometer manufactured by Impedimed ltd. and 4-electrode method. Measurement electrodes, current, and voltage have been placed according to 10–20 EEG system obtaining mutual BIS measurements from 4 different channels situated in pairs symmetrically from the midsagittal line. Obtained BIS data has been analyzed, assessing for symmetries and differences regarding healthy control data.Results. 7 out of 10 patients for Side-2-Side comparisons and 8 out 10 for central/lateral comparison presented values outside the range defined by healthy control group. When combined only 1 of 10 patients exhibited values within the healthy range. Conclusions. If these initial observations are confirmed with more patients, we can foresee emerging of noninvasive monitoring technology for brain damage with the potential to lead to paradigm shift in treatment of brain stroke and traumatic brain damage.
  •  
7.
  • Khodadad, Davood, 1985-, et al. (författare)
  • Optimized breath detection algorithm in electrical impedance tomography
  • 2018
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 39:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: This paper defines a method for optimizing the breath delineation algorithms used in electrical impedance tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern.Approach: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project.Main results: Three different algorithms are proposed that improve the breath detector performance by adding conditions on (1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, (2) minimum tidal impedance amplitude and (3) minimum tidal breath rate obtained from time-frequency analysis. As a baseline a zero-crossing algorithm has been used with some default parameters based on the Swisstom EIT device.Significance: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the receiver operating characterics. This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.
  •  
8.
  • Rems, Lea, et al. (författare)
  • Cell electrofusion using nanosecond electric pulses
  • 2013
  • Ingår i: Scientific Reports. - : Macmillan Publishers Ltd.. - 2045-2322. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrofusion is an efficient method for fusing cells using short-duration high-voltage electric pulses. However, electrofusion yields are very low when fusion partner cells differ considerably in their size, since the extent of electroporation (consequently membrane fusogenic state) with conventionally used microsecond pulses depends proportionally on the cell radius. We here propose a new and innovative approach to fuse cells with shorter, nanosecond (ns) pulses. Using numerical calculations we demonstrate that ns pulses can induce selective electroporation of the contact areas between cells (i.e. the target areas), regardless of the cell size. We then confirm experimentally on B16-F1 and CHO cell lines that electrofusion of cells with either equal or different size by using ns pulses is indeed feasible. Based on our results we expect that ns pulses can improve fusion yields in electrofusion of cells with different size, such as myeloma cells and B lymphocytes in hybridoma technology.
  •  
9.
  • Khodadad, Davood, 1985-, et al. (författare)
  • The Value of Phase Angle in Electrical Impedance Tomography Breath Detection
  • 2018
  • Ingår i: 2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama). - : Electromagnetics Academy. - 9784885523168 - 9781538654552 ; , s. 1040-1043
  • Konferensbidrag (refereegranskat)abstract
    • The objective of this paper is to report our investigation demonstrating that the phase angle information of complex impedance could be a simple indicator of a breath cycle in chest Electrical Impedance Tomography (EIT). The study used clinical neonatal EIT data. The results show that measurement of the phase angle from complex EIT data can be used as a complementary information for improving the conventional breath detection algorithms.
  •  
10.
  • Enejder, Annika, 1969, et al. (författare)
  • SHG Imaging for Tissue Engineering Applications
  • 2016
  • Ingår i: Second Harmonic Generation Imaging. - : CRC Press. - 9781439849156 - 9781439849149 ; , s. 409-426
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • Treatment of lost tissue oen relies on transplantations, either of donor or of autologous tissue. Both alternatives have limitations; there is for example a limited supply of donor transplants, which also require immunosuppression therapy with possible side eects. Transplanted autologous tissue may lack some of the functions of the original tissue and the procedure may also introduce complications at the donor site. In some cases, articial substitutes manufactured from nonbiological materials can be used, for example, synthetic polymer blood vessels or joint replacement prostheses. However, these replacements have drawbacks such as risk for infections, limited material durability, and lack of mechanisms for repair, growth, and remodeling. For these reasons, development of advanced articial tissue constructs with adaptive capabilities is desirable.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 311
Typ av publikation
tidskriftsartikel (141)
konferensbidrag (80)
patent (33)
doktorsavhandling (25)
bokkapitel (11)
licentiatavhandling (7)
visa fler...
annan publikation (6)
forskningsöversikt (6)
konstnärligt arbete (2)
rapport (2)
visa färre...
Typ av innehåll
refereegranskat (210)
övrigt vetenskapligt/konstnärligt (72)
populärvet., debatt m.m. (29)
Författare/redaktör
Danielsson, Mats, Pr ... (27)
Persson, Mikael, 195 ... (15)
Dobsicek Trefna, Han ... (15)
Augustine, Robin, 19 ... (14)
Roxhed, Niclas (7)
Danielsson, Mats (7)
visa fler...
Cubo, Rubén (6)
Medvedev, Alexander (5)
Lundh, Torbjörn, 196 ... (5)
van der Wijngaart, W ... (5)
Stemme, Göran, 1958 (5)
Brodin, Lars-Åke (5)
Danielsson, Mats, 19 ... (5)
Reinfeldt, Sabine, 1 ... (5)
Bjällmark, Anna (5)
Persson, Mats, 1987- (5)
Grönberg, Fredrik (5)
Ortiz Catalan, Max J ... (4)
Johansson, Anders (4)
Seoane, Fernando, 19 ... (4)
Janerot-Sjöberg, Bir ... (4)
Mastinu, Enzo, 1987 (4)
Bornefalk, Hans (4)
Antfolk, Christian (4)
Candefjord, Stefan, ... (4)
Cederström, Björn (4)
Haj-Hosseini, Neda, ... (4)
Åström, Mattias (4)
Behnke, O. (3)
Bargassa, P (3)
Blanc, F. (3)
Steen, Stig (3)
Andersson-Engels, St ... (3)
Seoane, Fernando (3)
Soltesz, Kristian (3)
Larsson, M (3)
Höglund, Odd (3)
Bertin, V. (3)
Karlsson, Staffan (3)
Aslanides, E. (3)
Holmin, Staffan (3)
McKelvey, Tomas, 196 ... (3)
Holmer, Mattias (3)
Magnusson, Charlotte (3)
Lammi, Mikko, 1961- (3)
Apostolakis, A. (3)
Benelli, A. (3)
Perez, Mauricio D. (3)
Monteith, Albert, 19 ... (3)
Möller, Sebastian (3)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (102)
Chalmers tekniska högskola (84)
Lunds universitet (48)
Uppsala universitet (34)
Linköpings universitet (24)
Göteborgs universitet (18)
visa fler...
Karolinska Institutet (18)
Umeå universitet (17)
Jönköping University (8)
Högskolan i Borås (6)
RISE (5)
Linnéuniversitetet (4)
Sveriges Lantbruksuniversitet (4)
Högskolan i Halmstad (2)
Stockholms universitet (2)
Örebro universitet (2)
Malmö universitet (2)
Luleå tekniska universitet (1)
Mälardalens universitet (1)
Gymnastik- och idrottshögskolan (1)
Högskolan Dalarna (1)
Blekinge Tekniska Högskola (1)
visa färre...
Språk
Engelska (307)
Svenska (2)
Odefinierat språk (1)
Japanska (1)
Forskningsämne (UKÄ/SCB)
Teknik (311)
Medicin och hälsovetenskap (84)
Naturvetenskap (35)
Lantbruksvetenskap (2)
Samhällsvetenskap (2)
Humaniora (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy