SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0167 5087 "

Sökning: L773:0167 5087

  • Resultat 1-25 av 160
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Blüm, P., et al. (författare)
  • A modular NaI(Tl) detector for 20-1000 MeV photons
  • 1983
  • Ingår i: Nuclear Instruments and Methods in Physics Research. - : Elsevier BV. - 0167-5087. ; 213:2-3, s. 251-259
  • Tidskriftsartikel (refereegranskat)abstract
    • A detector consisting of 54 NaI (Tl) modules is described. The detector has been optimized for the detection of 20-1000 MeV photons. An energy resolution (fwhm) of 5.5% at 130 MeV could be attained, and the stability has been better than 1% over several months.
  •  
2.
  • Scheffel, Jan, 1954- (författare)
  • Neutron Spectra from Beam-Heated Fusion Plasmas
  • 1984
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 224:3, s. 519-531
  • Tidskriftsartikel (refereegranskat)abstract
    • The spectra of fusion neutrons emerging from a deuterium-beam heated deuterium or tritium plasma yield information of both the bulk plasma and of the beam slowing down. A computer code has been developed to model plasma-plasma (p-p), beam-plasma (b-p) and beam-beam (b-b) interaction for the case of a single or several co-directed beams. It is found that for a high-temperature plasma (T ⪢ 1 keV) b-b interaction is negligible due to the low associated neutron emission. p-p neutron spectra reflect the bulk ion plasma temperature and density as well as toroidal rotational velocity. b-p spectra shifts and broadenings are sensitive to beam injection geometry and deposition, beam energy, ion and electron temperature, toroidal rotation and the density of neutrals. The mixing of full energy beam neutrals with half- and third-energy components has only a slight impact on the neutron spectrum when the beam power is held constant. For a JET-like Tokamak (D → D, beam power 5 MW, beam energy 160 keV) it is further found that for T ⪡ 8 keV the b-p neutron flux dominates, whereas for T ⪢ 8 keV the p-p flux dominates.
  •  
3.
  • Abat, E., et al. (författare)
  • Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
  • 2009
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002 .- 1872-9576. ; 607:2, s. 372-386
  • Tidskriftsartikel (refereegranskat)abstract
    • A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. in this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4. (C) 2009 Elsevier B.V. All rights reserved.
  •  
4.
  • Abata, E., et al. (författare)
  • Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 621:1-3, s. 134-150
  • Tidskriftsartikel (refereegranskat)abstract
    • A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20-350 GeV and beam impact points and angles corresponding to pseudo-rapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit. (C) 2010 Published by Elsevier B.V.
  •  
5.
  • Acharya, S, et al. (författare)
  • The ALICE transition radiation detector: Construction, operation, and performance
  • 2018
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 881, s. 88-127
  • Tidskriftsartikel (refereegranskat)abstract
    • The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection. © 2017 CERN for the benefit of the ALICE Collaboration.
  •  
6.
  • Adcox, K, et al. (författare)
  • Construction and performance of the PHENIX pad chambers
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 497:2-3, s. 263-293
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the Pad Chamber detector system in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The three station system provides space points along each track in the spectrometer arms at mid-rapidity and covers a total area of 88 m(2). Its main functions are to provide the track coordinate along the beam and to ensure reliable pattern recognition at very high particle multiplicity. A new concept for two dimensional wire chamber readout via its finely segmented cathode was developed. The full readout system, comprising 172 800 electronic channels, is described together with the challenging design of the chambers. The electronics, mounted on the outer chamber face, together with the chamber itself amounts to 1.2% of a radiation length. Results from cosmic ray tests, showing an average efficiency better than 99.5% for all chambers are presented. The experiences from the full scale operation in the first run are reported. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
7.
  • Adcox, K, et al. (författare)
  • PHENIX central arm tracking detectors
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 489-507
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX tracking system consists of Drift Chambers (DC), Pad Chambers (PC) and the Time Expansion Chamber (TEC). PC1/DC and PC2/TEC/PC3 form the inner and outer tracking units, respectively. These units link the track segments that transverse the RICH and extend to the EMCal. The DC measures charged particle trajectories in the r-phi direction to determine P-T of the particles and the invariant mass of particle pairs. The PCs perform 3D spatial point measurements for pattern recognition and longitudinal momentum reconstruction and provide spatial resolution of a few mm in both r-phi and z. The TEC tracks particles passing through the region between the RICH and the EMCal. The design and operational parameters of the detectors are presented and running experience during the first year of data taking with PHENIX is discussed. The observed spatial and momentum resolution is given which imposes a limitation on the identification and characterization of charged particles in various momentum ranges. (C) 2002 Published by Elsevier Science B.V.
  •  
8.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
9.
  • Adler, Jan-Olof, et al. (författare)
  • A broad range tagging spectrometer for the MAX-laboratory
  • 1997
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 388:1-2, s. 17-26
  • Tidskriftsartikel (refereegranskat)abstract
    • A broad range tagging spectrometer together with a new beam transport system for photonuclear experiments at the MAX-laboratory in Lund is described. The spectrometer consists of a quadrupole followed by an Elbek-type dipole and has a large momentum acceptance. It can produce both polarized and unpolarized tagged photons in the energy range 10–80 MeV with an energy resolution of about 300 keV.
  •  
10.
  • Adler, Jan-Olof, et al. (författare)
  • The upgraded photon tagging facility at the MAX IV Laboratory
  • 2013
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 715, s. 1-10
  • Tidskriftsartikel (refereegranskat)abstract
    • A description is given of the upgraded photon tagging facility at the MAX IV Laboratory. Two magnetic spectrometers are used to momentum analyze post-bremsstrahlung electrons. The tagged photon range extends from 10 to 180 MeV with an energy resolution of about 300 keV. The system has been operated at rates up to 4 x 10(6) photons s(-1) MeV (-1). Different diagnostic tools are described as well as the experimental program.
  •  
11.
  • Adler, SS, et al. (författare)
  • PHENIX on-line systems
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 560-592
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
12.
  • Aggarwal, M.M, et al. (författare)
  • Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade
  • 2018
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 903, s. 215-223
  • Tidskriftsartikel (refereegranskat)abstract
    • A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization dE/dx. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The dE/dx resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data. © 2018 Elsevier B.V.
  •  
13.
  • Ahlberg, Mats, et al. (författare)
  • Proton-Induced X-Ray Analysis of Steel Surfaces for Microprobe Purposes
  • 1975
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 123:2, s. 385-393
  • Tidskriftsartikel (refereegranskat)abstract
    • A study of the detection limits for the elements with Z = 15-92 in thick target steel surfaces using proton-induced X-ray technique has been performed. Samples were irradiated with a broad proton beam of 2 mm diameter and the X-rays were detected by a Si(Li) detector. Detection limits at levels down to the order of 10 ppm were achieved with simultaneous measurement of several elements. Mylar and chromium absorbers were introduced in front of the semiconductor detector and irradiations at two different proton energies (1.0 and 2.5 MeV) were carried out in order to elucidate their effects on detection limits. The results are valid for microbeam analysis.
  •  
14.
  • Ahmadi Afzadi, Masoud, et al. (författare)
  • Genome-wide expression analysis suggests a role for jasmonates in the resistance to blue mold in apple
  • 2018
  • Ingår i: Plant growth regulation (Print). - : Springer Science and Business Media LLC. - 0167-6903 .- 1573-5087. ; 85:3, s. 375-387
  • Tidskriftsartikel (refereegranskat)abstract
    • Blue mold, caused by the necrotrophic fungal pathogen Penicillium expansum, causes serious postharvest losses in apple, and threatens human health through production of the potent mycotoxin patulin. Recent studies indicate a quantitative control of resistance against this disease in apple cultivars. A whole genome apple microarray covering 60k transcripts was used to identify gene(s) that appear to be differentially regulated between resistant and susceptible cultivars in P. expansum-infected fruits. A number of potential candidates was encountered among defense- and oxidative stress-related genes, cell wall modification and lignification genes, and genes related to localization and transport. Induction of one cell wall-related gene and three genes involved in the 'down-stream' flavonoid biosynthesis pathway, demonstrates the fundamental role of the cell wall as an important barrier, and suggests that fruit flavonoids are involved in the resistance to blue mold. Moreover, exogenous application of the plant hormone methyl jasmonate (MeJA) reduced the symptoms resulting from inoculating apples with P. expansum. This is the first report linking MeJA and activation of cell wall and flavonoid pathway genes to resistance against blue mold in a study comparing different cultivars of domesticated apple. Our results provide an initial categorization of genes that are potentially involved in the resistance mechanism, and should be useful for developing tools for gene marker-assisted breeding of apple cultivars with an improved resistance to blue mold.
  •  
15.
  • Ainsworth, Robert, et al. (författare)
  • The influence of parasitic modes on beam dynamics for the European spallation source linac
  • 2014
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 734, s. 95-100
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Spallation Source (ESS) linac will consist of three families of superconducting RE cavities to accelerate protons to a final beam energy of 2.5 GeV for collision with the target. Beam induced HOMs in these cavities may drive the beam unstable and increase the cryogenic load, severely limiting the operation of the linac. The effect of these modes on the beam quality is investigated in detail using a numerical code dedicated to beam-HOM interaction. (C) 2012 Elsevier B.V. All rights reserved.
  •  
16.
  • Akkoyun, S., et al. (författare)
  • AGATA - Advanced GAmma Tracking Array
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 0167-5087 .- 1872-9576. ; 668, s. 26-58
  • Tidskriftsartikel (refereegranskat)abstract
    • The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation γ-ray spectrometer. AGATA is based on the technique of γ-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a γ ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realisation of γ-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterisation of the crystals was measured and compared with detector- response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximise its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer. © 2011 Elsevier B.V. All rights reserved.
  •  
17.
  • Akselsson, Roland, et al. (författare)
  • A Beam Mapping Method
  • 1971
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 91:4, s. 663-664
  • Tidskriftsartikel (refereegranskat)
  •  
18.
  • Alcorn, J, et al. (författare)
  • Basic instrumentation for Hall A at Jefferson Lab
  • 2004
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 522:3, s. 294-346
  • Tidskriftsartikel (refereegranskat)abstract
    • The instrumentation in Hall A at the Thomas Jefferson National Accelerator Facility was designed to study electro-and photo-induced reactions at very high luminosity and good momentum and angular resolution for at least one of the reaction products. The central components of Hall A are two identical high resolution spectrometers, which allow the vertical drift chambers in the focal plane to provide a momentum resolution of better than 2 x 10(-4). A variety of Cherenkov counters, scintillators and lead-glass calorimeters provide excellent particle identification. The facility has been operated successfully at a luminosity well in excess of 10(38) CM-2 s(-1). The research program is aimed at a variety of subjects, including nucleon structure functions, nucleon form factors and properties of the nuclear medium. (C) 2003 Elsevier B.V. All rights reserved.
  •  
19.
  • Alkhazov, GD, et al. (författare)
  • SPES4-pi: installation for exclusive study of nuclear reactions
  • 2005
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 551:2-3, s. 290-311
  • Tidskriftsartikel (refereegranskat)abstract
    • The paper describes the spectrometric system "SPES4-pi" used at the National Laboratory Saturne (CE Saclay, France) for the exclusive study of the baryon resonance excitation in inelastic alpha and d scattering on the proton, as well as coherent pion production in charge exchange reactions. The system consists of the magnetic spectrometer SPES4 and two wide-aperture position-sensitive detector arrays, equipped with wire chambers and scintillator hodoscopes, installed around a large-gap C-shape dipole magnet.
  •  
20.
  • Alme, J., et al. (författare)
  • The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
  • 2010
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 622:1, s. 316-367
  • Tidskriftsartikel (refereegranskat)abstract
    • The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m(3) and is operated in a 0.5T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb-Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report. (C) 2010 CERN for the benefit of the ALICE collaboration. Published by Elsevier B.V. All rights reserved.
  •  
21.
  • Almehed, Sverker, et al. (författare)
  • A Silicon-Tungsten Electromagnetic Calorimeter for LEP
  • 1991
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 305:2, s. 320-330
  • Tidskriftsartikel (refereegranskat)abstract
    • This report describes a silicon-tungsten electromagnetic calorimeter used to determine some beam properties and luminosity in the DELPHI experiment at LEP. The polar angular range covered by this detector is 5–8 mrad, which allows the detection of a Bhabha rate about 10 times the rate of produced Z particles at the peak cross section.
  •  
22.
  • Alvarez-Pol, H., et al. (författare)
  • Performance analysis for the CALIFA Barrel calorimeter of the (RB)-B-3 experiment
  • 2014
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 767, s. 453-466
  • Tidskriftsartikel (refereegranskat)abstract
    • The CALIFA calorimeter is an advanced detector for gamma rays and light charged particles, accordingly optimized for the demanding requirements of the physics programme proposed for the (RB)-B-3 facility at FAIR. The multipurpose character of CALIFA is required to fulfil challenging demands in energy resolution (5-6% at 1 MeV for gamma rays) and efficiency. Charged particles, e.g. protons of energies up to 320 MeV in the Barrel section, should also be identified with an energy resolution better to 1%. CALIFA is divided into two well-separated sections: a "Forward EndCap" and a cylindrical "Barrel" covering an angular range from 43.2 degrees to 140.3 degrees. The Barrel section, based on long CsI(Tl) pyramidal frustum crystals coupled to large area avalanche photodiodes (LAAPDs), attains the requested high efficiency for calorimetric purposes. The construction of the CALIFA Demonstrator, comprising 20% of the total detector, has already been initiated, and commissioning experiments are expected for 2014. The assessment of the capabilities and expected performance of the detector elements is a crucial step in their design, along with the prototypes evaluation. For this purpose, the Barrel geometry has been carefully implemented in the simulation package R3BRoot, including easily variable thicknesses of crystal wrapping and carbon fibre supports. A complete characterization of the calorimeter response (including efficiency, resolution, evaluation of energy and reconstruction losses) under different working conditions, with several physics cases selected to probe the detector performance over a wide range of applications, has been undertaken. Prototypes of different sections of the CALIFA Barrel have been modeled and their responses have been evaluated and compared with the experimental results. The present paper summarizes the outcome of the simulation campaign for the entire Barrel section and for the corresponding prototypes tested at different European installations. (C) 2014 Elsevier B.V. All rights reserved
  •  
23.
  • Anderberg, B, et al. (författare)
  • The design of a 3 GHz thermionic RF-gun and energy filter for MAX-lab
  • 2002
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 491:1-2, s. 307-313
  • Tidskriftsartikel (refereegranskat)abstract
    • A new pre-injector has been designed for the MAX-laboratory. It consists of an RF-gun and a magnetic energy filter. The newly designed RF-gun geometry will be operated at 3 GHz in the thermionic mode using a BaO cathode. The pre-injector will provide a 2.3 MeV electron beam in 3 ps micro pulses to a new injector system currently under construction. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
24.
  • Andersen, C. E., et al. (författare)
  • Medical proton dosimetry using radioluminescence from aluminium oxide crystals attached to optical-fiber cables
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 580:1, s. 466-468
  • Tidskriftsartikel (refereegranskat)abstract
    • The prime objective of this study is to investigate if radioluminescence (RL) from carbon-doped aluminum oxide (Al2O3:C) crystals potentially can be used for absorbed dose-rate measurements during proton radiotherapy. The RL from two separate (2 mg) Al2O3:C crystals attached to optical-fiber cables were recorded during irradiations in water in a 175 MeV clinical proton beam. The RL response for low-LET protons in the plateau region of the Bragg curve was found to closely resemble that observed for a clinical 6 MV X-ray beam. An identical response was found in the Bragg peak (where the dose-averaged LET is about 4 keV/mu m) for absorbed doses less than 0.3 Gy. For doses in the range of 0.3-3Gy, we observed a significant decrease in luminescence efficiency with LET. At 3 Gy, the luminescence efficiency was about 60% in the Bragg-peak region. The study implies that the RL-signal from Al2O3:C could potentially be suitable for medical proton dosimetry in the 0-0.3 Gy range even without any LET-dependent correction factors.
  •  
25.
  • Andersen, Ken, et al. (författare)
  • B-10 multi-grid proportional gas counters for large area thermal neutron detectors
  • 2013
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002 .- 1872-9576. ; 720, s. 116-121
  • Tidskriftsartikel (refereegranskat)abstract
    • He-3 was a popular material in neutrons detectors until its availability dropped drastically in 2008. The development of techniques based on alternative convertors is now of high priority for neutron research institutes. Thin films of B-10 or (B4C)-B-10 have been used in gas proportional counters to detect neutrons, but until now, only for small or medium sensitive area. We present here the multi-grid design, introduced at the ILL and developed in collaboration with ESS for LAN (large area neutron) detectors. Typically thirty (B4C)-B-10 films of 1 mu m thickness are used to convert neutrons into ionizing particles which are subsequently detected in a proportional gas counter. The principle and the fabrication of the multi-grid are described and some preliminary results obtained with a prototype of 200 cm x 8 cm are reported; a detection efficiency of 48% has been measured at 2.5 angstrom with a monochromatic neutron beam line, showing the good potential of this new technique. (C) 2013 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 160

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy