SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0167 8140 "

Sökning: L773:0167 8140

  • Resultat 1-25 av 531
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Johansson, Bengt, 1958-, et al. (författare)
  • Phantom study of radiation doses outside the target volume brachytherapy versus external radiotherapy of early breast cancer
  • 2003
  • Ingår i: Radiotherapy and Oncology. - Amsterdam : Elsevier. - 1879-0887 .- 0167-8140. ; 69:1, s. 107-112
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Brachytherapy is sometimes suggested as an adjuvant treatment after surgery of some tumours. When introducing this, it would be useful to have an estimate of the dose distribution to different body sites, both near and distant to target, comparing conventional external irradiation to brachytherapy. The aim of the present study was to determine radiation doses with both methods at different body sites, near and distant to target, in an experimental situation on an operated left sided breast cancer on a female Alderson phantom. Methods: Five external beam treatments with isocentric tangential fields were given by a linear accelerator. A specified dose of 1.0 Gy was given to the whole left sided breast volume. Five interstitial brachytherapy treatments were given to the upper, lateral quadrant of the left breast by a two plane, 10 needles implant. A dose of 1.0 Gy specified according to the Paris system was administered by a pulsed dose rate afterloading machine. Absorbed dose in different fixed dose points were measured by thermoluminescence dosimeters. Results: Both methods yielded an absorbed dose of the same size to the bone marrow and internal organs distant to target, 1.0-1.4% of the prescribed dose. There was a trend of lower doses to the lower half of the trunk and higher doses to the upper half of the trunk, respectively, by brachytherapy. A 90% reduction of absorbed dose with brachytherapy compared to external irradiation was found in the near-target region within 5 cm from target boundary where parts of the left lung and the heart are situated. If an adjuvant dose of 50 Gy is given with the external radiotherapy and brachytherapy, the absorbed dose in a part of the myocardium could be reduced from 31.8 to 2.1 Gy. Conclusions: Near target, brachytherapy yielded a considerably lower absorbed dose which is of special importance when considering radiation effects on the myocard and lungs. We could not demonstrate any difference of importance, in absorbed dose to dose points distant to target. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
  •  
5.
  • Kjellén, Elisabeth, et al. (författare)
  • Comparison of low dose nicotinamide versus benzamide, administered per os, as radiosensitizers in a C3H mammary carcinoma
  • 1988
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 1879-0887 .- 0167-8140. ; 12:4, s. 327-331
  • Tidskriftsartikel (refereegranskat)abstract
    • We have evaluated if any differences in tumor radiosensitization exist between the two adenosine diphosphate ribosyl transferase (ADPRT) inhibitors nicotinamide and benzamide at fractionated low doses. A significant radiosensitizing effect with nicotinamide at a 10 mg/kg per day dose was found in the tumor model used. We found, however, no radiosensitizing effect with benzamide given according to this schedule.
  •  
6.
  •  
7.
  • Olsson, L E, et al. (författare)
  • Three-dimensional dose mapping from gamma knife treatment using a dosimeter gel and MR-imaging
  • 1992
  • Ingår i: Radiotherapy and Oncology. - 0167-8140. ; 24:2, s. 6-82
  • Tidskriftsartikel (refereegranskat)abstract
    • A new method has been investigated for the mapping of dose distributions in three dimensions delivered by the Leksell gamma knife. The irradiation unit is used to selectively treat small volumes in the brain with single high doses of ionising radiation--a treatment procedure known as radiosurgery. The dosimetry method investigated utilises a dosimeter gel consisting of ferrous sulphate solution and agarose which is, prior to irradiation, loaded into a cavity in a spherical phantom. Chemical changes induced in the gel by the radiation are measured by means of an MR-scanner. This imaging method permits rapid evaluation of the dose distribution in an irradiated volume. It thus offers a potential verification of individual radiation intracranial target treatment regimes as well as quality assurance measurements, assuming that the precision and accuracy of the dose mapping are adequate. The dose and its distribution registered by the gel dosimeter, in this initial experiment, are in good agreement with corresponding computed data obtained with the KULA treatment planning system of the gamma knife. The gel has thus the potential of being an attractive alternative dose mapping method to those used at present in radiosurgery, i.e. radiographic film and small ionisation chambers. The precision of the dosimeter gel is, however, not yet sufficient high to be used as a basic dosimetry system for the gamma knife.
  •  
8.
  •  
9.
  • Weber, Lars, et al. (författare)
  • Verification of a dynamic wedge implementation in a pencil beam based dose planning system
  • 1995
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 1879-0887 .- 0167-8140. ; 37:Suppl. 1, s. 26-26
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of dynamic movements on linear accelerators during irradiation have found a revised interest lately due to the integration of computers to control the linear accelerator. An example of this is the generation of fields that resemble ordinary wedge fields. These fields are produced by moving one of the collimator blocks during irradiation, i. e. dynamic wedges.A pencil beam based system with the possibility of modelling dynamically modulated dose distributions from collimator movement specifications has extensively been investigated. Special interest has been focused on depth doses, profiles and output factors which have been generated by dynamic wedge fields. The data from the treatment planning system has been verified with measurements in water on a Varian 4 MV linear accelerator.The results indicate that calculations accurately predicts the outcome from dynamic wedges without any additional measurements than those used for characterisation of static open beams.
  •  
10.
  •  
11.
  • Adell, Gunnar, 1953-, et al. (författare)
  • p53 status : an indicator for the effect of preoperative radiotherapy of rectal cancer.
  • 1999
  • Ingår i: Radiotherapy and Oncology. - 0167-8140 .- 1879-0887. ; 51:2, s. 169-174
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Rectal carcinoma is a common malignancy, with a history of high local recurrence rates following surgery. In recent years. preoperative radiotherapy and refined surgical technique have improved local control rates.AIM: To investigate the relationship between expression of nuclear p53 protein and the outcome in rectal carcinoma, with and without short-term preoperative radiotherapy.MATERIAL: Specimens from 163 patients from the Southeast Swedish Health Care region included in the Swedish rectal cancer trial between 1987-1990.METHOD: New sections from the paraffin blocks of the preoperative biopsy and the surgical specimen were examined immunohistochemically using a p53 antibody (PAb 1801).RESULT: Expression of nuclear p53 protein was seen in 41% of the tumours. The p53 negative patients treated with preoperative radiotherapy had a significant reduction of local failure compared with the non-irradiated p53 negative patients (P = 0.0008). In contrast, p53 positive patients showed no benefit from preoperative radiotherapy. The interaction between p53 status and the benefit of radiotherapy was statistically significant (P = 0.018).CONCLUSION: Expression of nuclear p53 protein in rectal carcinoma seems to be a significant predictive factor for local treatment failure after preoperative radiotherapy. Further investigations are necessary to select patients for preoperative treatment based on analysis of the preoperative biopsies.
  •  
12.
  •  
13.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  •  
19.
  •  
20.
  • Blomquist, M, et al. (författare)
  • Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning
  • 1996
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140 .- 1879-0887. ; 39:3, s. 271-286
  • Tidskriftsartikel (refereegranskat)abstract
    • The calculation of an electron dose distribution in a patient is a difficult problem because of the presence of tissue and surface inhomogeneities. Verification of the dose planning system is therefore essential. In this investigation, a novel method is used to evaluate a commercially available system (Helax-TMS), at electron energies between 10 and 50 MeV, both for a conventional treatment unit and an MLC-collimated scanned beam unit with a helium-filled treatment head. First, the experiments were designed to verify the local beam database and some fundamental characteristics of the electron beam calculations. Secondly, a number of generalised situations that would be encountered in the clinical treatment planning were evaluated: oblique incidence, field shaping with multi-leaf collimator, bolus edges, and air cavities. Dose distributions in two generalised anatomical phantoms simulating a neck and a nose were also analysed. The results have, when so possible, been presented as the dose ratio within the 'flattened area' for dose profiles and down to the 'treatment depth' (80% dose level) for depth doses. In the penumbra region and in the dose fall-off region, the comparison has been represented by the distance deviation between calculated and measured dose profiles or depth doses. A new tool, 'volume integration', was used to evaluate the deviations from a more clinical point of view. Most results were within +/-2% in dose for volumes larger than a sphere with a diameter of 15 mm, or +/-2 mm in position. Dose deviations were generally found for oblique incidences and below heterogeneities such as small air cavities and bolus edges in limited volumes.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  • Brynolfsson, Patrik, et al. (författare)
  • Gray-level invariant Haralick texture features
  • 2018
  • Ingår i: Radiotherapy and Oncology. - : Elsevier. - 0167-8140 .- 1879-0887. ; 127, s. S279-S280
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 531
Typ av publikation
konferensbidrag (278)
tidskriftsartikel (242)
forskningsöversikt (9)
proceedings (redaktörskap) (1)
annan publikation (1)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (309)
refereegranskat (221)
populärvet., debatt m.m. (1)
Författare/redaktör
Mavroidis, P (71)
Toma-Dasu, I (48)
Brahme, A (47)
Papanikolaou, N (39)
Lind, B (35)
Dasu, A (28)
visa fler...
Glimelius, Bengt (21)
Steineck, G (20)
Ferreira, BC (19)
Gagliardi, G. (18)
Lax, I (18)
Zackrisson, Björn (16)
Shi, C (16)
Karlsson, Mikael (15)
Lind, BK (15)
Stathakis, S (15)
Lind, H. (14)
Lundell, M (14)
Nyman, Jan, 1956 (13)
Nyholm, Tufve (13)
Al-Abany, M (13)
Johansson, Karl-Axel (13)
Nilsson, S. (12)
Avall-Lundqvist, E (12)
Kalkner, KM (11)
Glimelius, B (11)
Nilsson, Per (11)
Dunberger, G (11)
Knöös, Tommy (10)
Johansson, KA (10)
Waldenstrom, AC (10)
Nilsson, J. (9)
Arriagada, R (9)
Andreo, P (9)
Svensson, R (9)
Turesson, Ingela (9)
Uhrdin, J (9)
Friesland, S (8)
Alevronta, E (8)
Toma-Daşu, Iuliana (8)
Wennberg, B. (8)
Hyodynmaa, S (8)
Baltas, D (8)
Onjukka, E (8)
Olsson, Caroline, 19 ... (7)
Steineck, Gunnar, 19 ... (7)
Kjellén, Elisabeth (7)
Lindberg, K (7)
Gudowska, I (7)
van Elmpt, W (7)
visa färre...
Lärosäte
Karolinska Institutet (378)
Uppsala universitet (70)
Umeå universitet (48)
Lunds universitet (47)
Göteborgs universitet (42)
Linköpings universitet (20)
visa fler...
Kungliga Tekniska Högskolan (13)
Stockholms universitet (11)
Örebro universitet (11)
Chalmers tekniska högskola (2)
Jönköping University (1)
Sophiahemmet Högskola (1)
visa färre...
Språk
Engelska (530)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (168)
Teknik (9)
Naturvetenskap (7)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy