SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Auweter S.) "

Search: WFRF:(Auweter S.)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Yaroshenko, A., et al. (author)
  • Preclinical x-ray dark-field radiography for pulmonary emphysema evaluation
  • 2013
  • In: ISBI 2013 - 2013 IEEE 10th International Symposium on Biomedical Imaging : From Nano to Macro - From Nano to Macro. - 1945-7928 .- 1945-8452. - 9781467364553 - 9781467364560 ; , s. 370-373
  • Conference paper (peer-reviewed)abstract
    • Pulmonary emphysema is a widespread disorder characterized by irreversible destruction of alveolar walls. The spatial distribution of the disease, so far, could only be obtained using an x-ray CT scan, implying a high patient dose. X-ray scattering on alveolar structures is measured in the dark-field signal. The signal is dependent on the size of alveoli and therefore, a combination of absorption and dark-field signal is explored for mapping the distribution of emphysema in the lung on x-ray projection images. In this study three excised murine lungs with pulmonary emphysema and three control samples were imaged using a compact, cone-beam, small-animal x-ray dark-field scanner with a polychromatic source. Statistical analysis of the results, based on a combination of transmission and dark-field signals, revealed a distinct difference between emphysematous and control samples. Subsequently, the distribution of emphysema was mapped out per-pixel for the lungs and showed good agreement with histological findings.
  •  
2.
  • Velroyen, A, et al. (author)
  • Grating-based X-ray Dark-field Computed Tomography of Living Mice.
  • 2015
  • In: EBioMedicine. - : Elsevier BV. - 2352-3964. ; 2:10, s. 1500-1506
  • Journal article (peer-reviewed)abstract
    • Changes in x-ray attenuating tissue caused by lung disorders like emphysema or fibrosis are subtle and thus only resolved by high-resolution computed tomography (CT). The structural reorganization, however, is of strong influence for lung function. Dark-field CT (DFCT), based on small-angle scattering of x-rays, reveals such structural changes even at resolutions coarser than the pulmonary network and thus provides access to their anatomical distribution. In this proof-of-concept study we present x-ray in vivo DFCTs of lungs of a healthy, an emphysematous and a fibrotic mouse. The tomographies show excellent depiction of the distribution of structural - and thus indirectly functional - changes in lung parenchyma, on single-modality slices in dark field as well as on multimodal fusion images. Therefore, we anticipate numerous applications of DFCT in diagnostic lung imaging. We introduce a scatter-based Hounsfield Unit (sHU) scale to facilitate comparability of scans. In this newly defined sHU scale, the pathophysiological changes by emphysema and fibrosis cause a shift towards lower numbers, compared to healthy lung tissue.
  •  
3.
  • Velroyen, A., et al. (author)
  • Microbubbles as a scattering contrast agent for grating-based x-ray dark-field imaging
  • 2013
  • In: Physics in Medicine and Biology. - 1361-6560. ; 58:4, s. 37-46
  • Journal article (peer-reviewed)abstract
    • In clinically established-absorption-based-biomedical x-ray imaging, contrast agents with high atomic numbers (e.g. iodine) are commonly used for contrast enhancement. The development of novel x-ray contrast modalities such as phase contrast and dark-field contrast opens up the possible use of alternative contrast media in x-ray imaging. We investigate using ultrasound contrast agents, which unlike iodine-based contrast agents can also be administered to patients with renal impairment and thyroid dysfunction, for application with a recently developed novel x-ray dark-field imaging modality. To produce contrast from these microbubble-based contrast agents, our method exploits ultra-small-angle coherent x-ray scattering. Such scattering dark-field x-ray images can be obtained with a grating-based x-ray imaging setup, together with refraction-based differential phase-contrast and the conventional attenuation contrast images. In this work we specifically show that ultrasound contrast agents based on microbubbles can be used to produce strongly enhanced dark-field contrast, with superior contrast-to-noise ratio compared to the attenuation signal. We also demonstrate that this method works well with an x-ray tube-based setup and that the relative contrast gain even increases when the pixel size is increased from tenths of microns to clinically compatible detector resolutions about up to a millimetre.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view