SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Broeders M.) "

Sökning: WFRF:(Broeders M.)

  • Resultat 1-25 av 38
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Gudowski, Waclaw, et al. (författare)
  • Review of the European project - Impact of Accelerator-Based Technologies on Nuclear Fission Safety (IABAT)
  • 2001
  • Ingår i: Progress in nuclear energy (New series). - 0149-1970 .- 1878-4224. ; 38:1-2, s. 135-151
  • Tidskriftsartikel (refereegranskat)abstract
    • The IABAT project - Impact of Accelerator Based Technologies on Nuclear Fission Safety - started in 1996 in the frame of 4(th) Framework Programme of the European Union, R&D specific programme Nuclear fission safety 1994-1998, area A.2 Exploring innovative approaches/Fuel cycle concepts, as one of the first common European activities in ADS. The project was completed October 31, 1999. The overall objective of the IABAT project has been a preliminary assessment of the potential of Accelerator-Driven Systems (ADS) for transmutation of nuclear waste and for nuclear energy production with minimum waste generation. Moreover, more specific topics related to nuclear data and code development for ADS have been studied in more detail. Four ADSs have been studied for different fuel/coolant combinations: liquid metal coolant and solid fuel, liquid metal coolant and dispersed fuel, and fast and thermal molten salt systems. Target studies comprised multiple target solutions and radiation damage problems in a target environment. In a tool development part of the project a methodology of subcriticality monitoring has been developed based on Feynman-alpha and Rossi-alpha methods. Moreover, a new Monte-Carlo burnup code taking full advantage of continuous neutron cross-section data has been developed and benchmarked. Impact on the risk from high-level waste repositories fi om radiotoxicity reduction using ADS has been assessed giving no crystal-clear benefits of ADS for repository radiotoxicity reduction but concluding some important prerequisites for effective transmutation. In proliferation studies important differences between critical reactors and ADS have been underlined and non-proliferation measures have been proposed. In assessment of accelerator technology costing models have been created that allow the circular and linear accelerator options to be compared and the effect of parameter variations examined. The calculations reported show that cyclotron systems would be more economical, due mainly to the advantage of the cost of RF power supplies. However, the accelerator community regards with skepticism the possibility of transporting and extracting more than a 10mA beam current from a 1GeV cyclotron and therefore technical factors may limit the application of cyclotrons. Finally, this review summarizes development of nuclear data in the energy region between 20 Mev and 150 MeV. Neutron and proton transport data files for Fe, Ni, Pb, Th, U-238 and Pu-239 have been created. The high-energy part of the data files consists completely of results from model calculations, which are benchmarked against the available experimental data. Although there is obviously future work left regarding fine-tuning of several parts of the data files, the representation of nuclear reaction information up to 150 MeV is already better than can be attained with intranuclear cascade codes.
  •  
4.
  • Pashayan, N, et al. (författare)
  • Personalized early detection and prevention of breast cancer: ENVISION consensus statement
  • 2020
  • Ingår i: Nature reviews. Clinical oncology. - : Springer Science and Business Media LLC. - 1759-4782 .- 1759-4774. ; 17:11, s. 687-705
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Collaborative on Personalized Early Detection and Prevention of Breast Cancer (ENVISION) brings together several international research consortia working on different aspects of the personalized early detection and prevention of breast cancer. In a consensus conference held in 2019, the members of this network identified research areas requiring development to enable evidence-based personalized interventions that might improve the benefits and reduce the harms of existing breast cancer screening and prevention programmes. The priority areas identified were: 1) breast cancer subtype-specific risk assessment tools applicable to women of all ancestries; 2) intermediate surrogate markers of response to preventive measures; 3) novel non-surgical preventive measures to reduce the incidence of breast cancer of poor prognosis; and 4) hybrid effectiveness–implementation research combined with modelling studies to evaluate the long-term population outcomes of risk-based early detection strategies. The implementation of such programmes would require health-care systems to be open to learning and adapting, the engagement of a diverse range of stakeholders and tailoring to societal norms and values, while also addressing the ethical and legal issues. In this Consensus Statement, we discuss the current state of breast cancer risk prediction, risk-stratified prevention and early detection strategies, and their implementation. Throughout, we highlight priorities for advancing each of these areas.
  •  
5.
  •  
6.
  •  
7.
  • Ancelle-Park, R., et al. (författare)
  • Summary of the evidence of breast cancer service screening outcomes in Europe and first estimate of the benefit and harm balance sheet
  • 2012
  • Ingår i: Journal of Medical Screening. - : SAGE Publications. - 0969-1413 .- 1475-5793. ; 19, s. 5-13
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To construct a European 'balance sheet' of key outcomes of population-based mammographic breast cancer screening, to inform policy-makers, stakeholders and invited women. Methods From the studies reviewed, the primary benefit of screening, breast cancer mortality reduction, was compared with the main harms, over-diagnosis and false-positive screening results (FPRs). Results Pooled estimates of breast cancer mortality reduction among invited women were 25% in incidence-based mortality studies and 31% in case-control studies (38% and 48% among women actually screened). Estimates of over-diagnosis ranged from 1% to 10% of the expected incidence in the absence of screening. The combined estimate of over-diagnosis for screened women, from European studies correctly adjusted for lead time and underlying trend, was 6.5%. For women undergoing 10 biennial screening tests, the estimated cumulative risk of a FPR followed by non-invasive assessment was 17%, and 3% having an invasive assessment. For every 1000 women screened biennially from age 50-51 until age 68-69 and followed up to age 79, an estimated seven to nine lives are saved, four cases are over-diagnosed, 170 women have at least one recall followed by non-invasive assessment with a negative result and 30 women have at least one recall followed by invasive procedures yielding a negative result. Conclusions The chance of saving a woman's life by population-based mammographic screening of appropriate quality is greater than that of over-diagnosis. Service screening in Europe achieves a mortality benefit at least as great as the randomized controlled trials. These outcomes should be communicated to women offered service screening in Europe.
  •  
8.
  •  
9.
  •  
10.
  • Boita, Joana, et al. (författare)
  • Validation of a candidate instrument to assess image quality in digital mammography using ROC analysis
  • 2021
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 1872-7727 .- 0720-048X. ; 139
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo validate a candidate instrument, to be used by different professionals to assess image quality in digital mammography (DM), against detection performance results.MethodsA receiver operating characteristics (ROC) study was conducted to assess the detection performance in DM images with four different image quality levels due to different quality issues. Fourteen expert breast radiologists from five countries assessed a set of 80 DM cases, containing 60 lesions (40 cancers, 20 benign findings) and 20 normal cases. A visual grading analysis (VGA) study using a previously-described candidate instrument was conducted to evaluate a subset of 25 of the images used in the ROC study. Eight radiologists that had participated in the ROC study, and seven expert breast-imaging physicists, evaluated this subset. The VGA score (VGAS) and the ROC and visual grading characteristics (VGC) areas under the curve (AUCROC and AUCVGC) were compared.ResultsNo large differences in image quality among the four levels were detected by either ROC or VGA studies. However, the ranking of the four levels was consistent: level 1 (partial AUCROC: 0.070, VGAS: 6.77) performed better than levels 2 (0.066, 6.15), 3 (0.061, 5.82), and 4 (0.062, 5.37). Similarity between radiologists’ and physicists’ assessments was found (average VGAS difference of 10 %).ConclusionsThe results from the candidate instrument were found to correlate with those from ROC analysis, when used by either observer group. Therefore, it may be used by different professionals, such as radiologists, radiographers, and physicists, to assess clinically-relevant image quality variations in DM.
  •  
11.
  •  
12.
  • Moss, S. M., et al. (författare)
  • The impact of mammographic screening on breast cancer mortality in Europe : a review of trend studies
  • 2012
  • Ingår i: Journal of Medical Screening. - : SAGE Publications. - 0969-1413 .- 1475-5793. ; 19, s. 26-32
  • Forskningsöversikt (refereegranskat)abstract
    • Objective Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value. Methods A literature review identified 17 papers, of which 12 provided quantitative estimates of the impact of screening. Due to differences in comparisons and outcome measures, no pooled estimate of effectiveness was calculated. Results Comparisons included breast cancer mortality before and after the introduction of screening, trends in early and late starting areas and trends in age groups affected and unaffected by screening. Studies that calculated the percentage annual change after the start of screening found reductions of 1-9% per year (1%, 2.3-2.8% and 9% for those with adequate follow-up). Of studies that compared mortality in time periods before and after introduction of screening, three single country studies all had adequate follow-up and estimated mortality reductions ranging from 28% to 36%. Limitations of studies of population mortality rates include the inability to exclude deaths in women with breast cancer diagnosed before invitation to screening, diluting any observable impact of screening, and the gradual implementation of screening in a country or region. Conclusions Although analysing population breast cancer mortality rates over time can be a first step in examining changes following the introduction of screening, this method is of limited value for assessment of screening impact. Other methods and individual data are necessary to properly quantify the effect.
  •  
13.
  •  
14.
  •  
15.
  • Paschke, K. D., et al. (författare)
  • Experimental determination of the complete spin structure for (p)over-barp ->(Lambda)over-bar Lambda at p((p)over-bar)=1.637 GeV/c
  • 2006
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 74:1, s. 015206-
  • Tidskriftsartikel (refereegranskat)abstract
    • The reaction (p) over barp -> (Lambda) over bar Lambda -> (p) over bar pi(+)p pi(-) has been measured with high statistics at a beam momentum of p((p) over bar)=1.637GeV/c. The use of a transversely polarized frozen-spin target combined with the self-analyzing property of Lambda/(Lambda) over bar decay allows access to unprecedented information on the spin structure of the interaction. The most general spin-scattering matrix can be written in terms of 11 real parameters for each bin of scattering angle; each of these parameters is determined with reasonable precision. From these results, all conceivable spin correlations are determined with inherent self-consistency. Good agreement is found with the few previously existing measurements of spin observables in (p) over barp ->(Lambda) over bar Lambda near this energy. Existing theoretical models do not give good predictions for those spin observables that had not been previously measured.
  •  
16.
  •  
17.
  • Boita, Joana, et al. (författare)
  • Development and content validity evaluation of a candidate instrument to assess image quality in digital mammography : A mixed-method study
  • 2021
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X. ; 134
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop a candidate instrument to assess image quality in digital mammography, by identifying clinically relevant features in images that are affected by lower image quality. Methods: Interviews with fifteen expert breast radiologists from five countries were conducted and analysed by using adapted directed content analysis. During these interviews, 45 mammographic cases, containing 44 lesions (30 cancers, 14 benign findings), and 5 normal cases, were shown with varying image quality. The interviews were performed to identify the structures from breast tissue and lesions relevant for image interpretation, and to investigate how image quality affected the visibility of those structures. The interview findings were used to develop tentative items, which were evaluated in terms of wording, understandability, and ambiguity with expert breast radiologists. The relevance of the tentative items was evaluated using the content validity index (CVI) and modified kappa index (k*). Results: Twelve content areas, representing the content of image quality in digital mammography, emerged from the interviews and were converted into 29 tentative items. Fourteen of these items demonstrated excellent CVI ≥ 0.78 (k* > 0.74), one showed good CVI < 0.78 (0.60 ≤ k* ≤ 0.74), while fourteen were of fair or poor CVI < 0.78 (k* ≤ 0.59). In total, nine items were deleted and five were revised or combined resulting in 18 items. Conclusions: By following a mixed-method methodology, a candidate instrument was developed that may be used to characterise the clinically-relevant impact that image quality variations can have on digital mammography.
  •  
18.
  • Boita, Joana, et al. (författare)
  • How does image quality affect radiologists’ perceived ability for image interpretation and lesion detection in digital mammography?
  • 2021
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 31:7, s. 5335-5343
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To study how radiologists’ perceived ability to interpret digital mammography (DM) images is affected by decreases in image quality. Methods: One view from 45 DM cases (including 30 cancers) was degraded to six levels each of two acquisition-related issues (lower spatial resolution and increased quantum noise) and three post-processing-related issues (lower and higher contrast and increased correlated noise) seen during clinical evaluation of DM systems. The images were shown to fifteen breast screening radiologists from five countries. Aware of lesion location, the radiologists selected the most-degraded mammogram (indexed from 1 (reference) to 7 (most degraded)) they still felt was acceptable for interpretation. The median selected index, per degradation type, was calculated separately for calcification and soft tissue (including normal) cases. Using the two-sided, non-parametric Mann-Whitney test, the median indices for each case and degradation type were compared. Results: Radiologists were not tolerant to increases (medians: 1.5 (calcifications) and 2 (soft tissue)) or decreases (median: 2, for both types) in contrast, but were more tolerant to correlated noise (median: 3, for both types). Increases in quantum noise were tolerated more for calcifications than for soft tissue cases (medians: 3 vs. 4, p = 0.02). Spatial resolution losses were considered less acceptable for calcification detection than for soft tissue cases (medians: 3.5 vs. 5, p = 0.001). Conclusions: Perceived ability of radiologists for image interpretation in DM was affected not only by image acquisition-related issues but also by image post-processing issues, and some of those issues affected calcification cases more than soft tissue cases. Key Points: • Lower spatial resolution and increased quantum noise affected the radiologists’ perceived ability to interpret calcification cases more than soft tissue lesion or normal cases. • Post-acquisition image processing-related effects, not only image acquisition-related effects, also impact the perceived ability of radiologists to interpret images and detect lesions. • In addition to current practices, post-acquisition image processing-related effects need to also be considered during the testing and evaluation of digital mammography systems.
  •  
19.
  • Broeders, B., et al. (författare)
  • Epidemiology of disorders of gut-brain interaction in Belgium and differences between two language groups: Results from the Rome foundation global epidemiology study
  • 2023
  • Ingår i: Neurogastroenterology and Motility. - 1350-1925. ; 35:6
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThe Rome Foundation carried out a worldwide epidemiology study on DGBI according to the Rome IV criteria in 33 countries, including Belgium. DGBI prevalence varied between continents and countries, but prevalence differences within language groups in a single country have not yet been described. MethodsWe analyzed the prevalence rates of 18 DGBI and their psychosocial impact in Belgium in the French and Dutch language groups. Key ResultsDGBI prevalence was similar in the French-speaking and Dutch-speaking population. Having one or more DGBI was negatively associated with psychosocial well-being. The scores for depression were lower in the Dutch-speaking participants with one or more DGBI compared to the French-speaking participants. Interestingly, we also found significantly lower scores in the general Dutch-speaking versus the French-speaking population for depression and non-gastrointesinal somatic symptoms, and higher global physical health and mental health quality-of-life component scores. In the Dutch-speaking group, medication use for gastric acid was lower, but use of prescribed analgesics was more common. Nevertheless, the use of non-prescribed pain medication was higher in the French-speaking group. Anxiety and sleep medication use was also higher in the latter group. Conclusions & InterferencesThe results of this first in-depth analysis of Rome IV DGBI in Belgium show a higher prevalence for some DGBI in the French-speaking cohort, and a larger associated disease burden. These differences between language/culture groups in the same country support the psychosocial pathophysiological model of DGBI.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  • Kootker, Lisette M., et al. (författare)
  • The effects of decomposition and environment on antemortem H-Pb-Sr isotope compositions and degradation of human scalp hair : Actualistic taphonomic observations
  • 2020
  • Ingår i: Forensic Science International. - : Elsevier. - 0379-0738 .- 1872-6283. ; 312
  • Tidskriftsartikel (refereegranskat)abstract
    • Multi-isotope analysis (e.g., Sr–Pb–O–H–C–N) of human scalp hair is routinely used in forensic investigations of human remains to constrain the geographic origin of unidentified bodies, and to investigate antemortem mobility patterns. However, while it is known that postmortem processes can affect the preservation of, or even overprint, the biogenic isotopic signatures in hair, the speed and nature of these processes have rarely been studied. This study investigates the effects of decomposition and environment on the H–Pb–Sr isotope compositions of human hair as well as the relationship between structural hair shaft degradation and isotopic signature change over time. Human scalp hair samples from four body donations were collected at different stages throughout gross body decomposition. The willed-donated bodies were placed to decompose outdoors at the Forensic Anthropology Research Facility (FARF) at Texas State University. Hair fibers from two of the donations were examined using scanning electron microscopy (SEM) and high-resolution light microscopy (HRLM). Chemical and microbiological degradation of hair fibers occurred rapidly after placement of the body outdoors. Measurements of scalp hair isotopic composition demonstrated that H–Pb–Sr isotope ratios were altered within days after environmental exposure, presumably by deposition, leaching and/or exchange with the local bioavailable soil, and vapor. The degree of physical hair degradation and changes in H–Pb–Sr isotope composition were not correlated. We conclude that antemortem isotopic H–Pb–Sr isotope ratios are difficult to recover in hairs derived from decomposing whole bodies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 38

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy