1.
  • Blanco, A., et al. (författare)
  • Performance of timing resistive plate chambers with relativistic neutrons from 300 to 1500 MeV
  • 2015
  • Ingår i: Journal of Instrumentation. - : IOP Publishing. - 1748-0221. ; 10:2
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype composed of four resistive plate chamber layers has been exposed to quasi-monoenergetic neutrons produced from a deuteron beam of varying energy (300 to 1500 AMeV) in experiment S406 at GSI, Darmstad, Germany. Each layer, with an active area of about 2000 × 500 mm2, is made of modules containing the active gaps, all in multigap construction. Each gap is defined by 0.3 mm nylon mono-filaments positioned between 2.85 mm thick float glass electrodes. The modules are operated in avalanche mode with a non-flammable gas mixture composed of 90% C2H2F4 and 10% SF6. The signals are readout by a pick-up electrode formed by 15 copper strips (per layer), spaced at a pitch of 30 mm, connected at both sides to timing front end electronics. Measurements of the time of flight jitter of neutrons, in the mentioned energy range, point to a contribution of the resistive plate chamber in the order of 150 ps, independent of the neutron energy.
  •  
2.
  • Machado, J., et al. (författare)
  • Performance of timing Resistive Plate Chambers with protons from 200 to 800 MeV
  • 2015
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 10:1, s. C01043-
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype composed of four resistive plate chamber layers has been exposed to quasi-monoenergetic protons produced from a deuteron beam of varying energy (200 to 800 AMeV) in experiment S406 at GSI, Darmstadt, Germany. The aim of the experiment is to characterize the response of the prototype to protons in this energy range, which deposit from 1.75 to 6 times more energy than minimum ionizing particles. Each layer, with an active area of about 2000 × 500 mm 2 , is made of modules containing the active gaps, all in multigap construction. Each gap is defined by 0.3 mm nylon mono-filaments positioned between 2.85 mm thick float glass electrodes. The modules are operated in avalanche mode with a non-flammable gas mixture composed of 90% C 2 H 2 F 4 and 10% SF 6 . The signals are readout by a pick-up electrode formed by 15 copper strips (per layer), spaced at a pitch of 30 mm, connected at both sides to timing front end electronics. Results show an uniform efficiency close to 100% along with a timing resolution of around 60 ps on the entire 2000 × 500 mm 2 area.
  •  
3.
  • Cabanelas, P., et al. (författare)
  • Commissioning of the CALIFA Barrel Calorimeter of the R 3 B Experiment at FAIR
  • 2020
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 1667:1
  • Konferensbidrag (refereegranskat)abstract
    • CALIFA is the high efficiency and energy resolution calorimeter for the R3B experiment at FAIR, intended for detecting high energy charged particles and γ-rays in inverse kinematics direct reactions. It surrounds the reaction target in a segmented configuration of Barrel and Forward End-Cap pieces. The CALIFA Barrel consists of 1952 detection units made of CsI(Tl) long-shaped scintillator crystals, and it is being commissioned during the Phase0 experiments at FAIR. The first setup for the CALIFA Barrel commissioning is presented here. Results of detector performance with γ-rays are obtained, and show that the system fulfills the design requirements.
  •  
4.
  • Cabanelas, P., et al. (författare)
  • Performance recovery of long CsI(Tl) scintillator crystals with APD-based readout
  • 2020
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 965
  • Tidskriftsartikel (refereegranskat)abstract
    • CALIFA is the high efficiency and energy resolution calorimeter for the R3B experiment at FAIR, intended for detecting high energy light charged particles and gamma rays in scattering experiments, and is being commissioned during the Phase-0 experiments at FAIR, between 2018 and 2020. It surrounds the reaction target in a segmented configuration with 2432 detection units made of long CsI(Tl) finger-shaped scintillator crystals. CALIFA has a 10 year intended operational lifetime as the R3B calorimeter, necessitating measures to be taken to ensure enduring performance. In this paper we present a systematic study of two groups of 6 different detection units of the CALIFA detector after more than four years of operation. The energy resolution and light output yield are evaluated under different conditions. Tests cover the aging of the first detector units assembled and investigates recovery procedures for degraded detection units. A possible reason for the observed degradation is given, pointing to the crystal-APD coupling.
  •  
5.
  • Cortina-Gil, D., et al. (författare)
  • CALIFA, a Dedicated Calorimeter for the R3B/FAIR
  • 2014
  • Ingår i: Nuclear Data Sheets. - : Elsevier BV. - 1095-9904 .- 0090-3752. ; 120, s. 99-101
  • Tidskriftsartikel (refereegranskat)abstract
    • The R3B experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the R3B experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction.
  •  
6.
  • Diaz Fernandez, Paloma, 1983, et al. (författare)
  • Quasifree (p, pN) scattering of light neutron-rich nuclei near N=14
  • 2018
  • Ingår i: Physical Review C. - 2469-9985 .- 2469-9993. ; 97:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: For many years, quasifree scattering reactions in direct kinematics have been extensively used to study the structure of stable nuclei, demonstrating the potential of this approach. The (RB)-B-3 collaboration has performed a pilot experiment to study quasifree scattering reactions in inverse kinematics for a stable C-12 beam. The results from that experiment constitute the first quasifree scattering results in inverse and complete kinematics. This technique has lately been extended to exotic beams to investigate the evolution of shell structure, which has attracted much interest due to changes in shell structure if the number of protons or neutrons is varied. Purpose: In this work we investigate for the first time the quasifree scattering reactions (p, pn) and (p, 2p) simultaneously for the same projectile in inverse and complete kinematics for radioactive beams with the aim to study the evolution of single-particle properties from N = 14 to N = 15. Method: The structure of the projectiles O-23, O-22, and N-21 has been studied simultaneously via (p, pn) and (p, 2p) quasifree knockout reactions in complete inverse kinematics, allowing the investigation of proton and neutron structure at the same time. The experimental data were collected at the (RB)-B-3-LAND setup at GSI at beam energies of around 400 MeV/u. Two key observables have been studied to shed light on the structure of those nuclei: the inclusive cross sections and the corresponding momentum distributions. Conclusions: The knockout reactions (p, pn) and (p, 2p) with radioactive beams in inverse kinematics have provided important and complementary information for the study of shell evolution and structure. For the (p, pn) channels, indications of a change in the structure of these nuclei moving from N = 14 to N = 15 have been observed, i.e., from the 0d(5/2) shell to the 1s(1/2). This supports previous observations of a subshell closure at N = 14 for neutron-rich oxygen isotopes and its weakening for the nitrogen isotopes.
  •  
7.
  • Graña-González, A., et al. (författare)
  • Quasi-free (p,2p) reactions in inverse kinematics for studying the fission yield dependence on temperature
  • 2023
  • Ingår i: FAIR next generation scientists - 7th Edition Workshop : FAIRness2022 - FAIRness2022. - 1824-8039. ; 419
  • Konferensbidrag (refereegranskat)abstract
    • Despite the recent experimental and theoretical progress in the investigation of the nuclear fission process, a complete description still represents a challenge in nuclear physics because it is a very complex dynamical process, whose description involves the coupling between intrinsic and collective degrees of freedom, as well as different quantum-mechanical phenomena. To improve on the existing data on nuclear fission, we produce fission reactions of heavy nuclei in inverse kinematics by using quasi-free (p,2p) scattering, which induce fission through particle-hole excitations that can range from few to ten's of MeV. The measurement of the four-momenta of the two outgoing protons allows to reconstruct the excitation energy of the fissioning compound nucleus and therefore to study the evolution of the fission yields with temperature. The realization of this kind of experiment requires a complex experimental setup, providing full isotopic identification of both fission fragments and an accurate measurement of the momenta of the two outgoing protons. This was realized recently at the GSI/FAIR facility and here some preliminary results are presented.
  •  
8.
  • Knyazev, A., et al. (författare)
  • Simulations of light collection in long tapered CsI(Tl) scintillators using real crystal surface data and comparisons to measurement
  • 2021
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Simulation results for light transport in long tapered CsI(Tl) crystals using look-up tables (LUTs) are presented. The LUTs were derived from the topography of a polished and a lapped surface of a CsI(Tl) crystal measured with atomic force microscopy. Simulations with different combinations of polished and lapped surfaces were performed, to extract the non-uniformity of light collection depending on the interaction point, and compared to experimental results. The simulations reproduce the general trend given by the measurements, and show that more homogeneous light collection is attained when all lateral sides of the crystal are lapped. For the lapped crystal the simulation model is most sensitive to the reflectivity of the enhanced specular reflector (ESR) foil surrounding the crystal, which is one of several properties influencing the light transport examined in this study. The sensitivity of the light-output non-uniformity to variations in the absorption length observed in a batch of CsI(Tl) crystals in a previous study is also discussed. Residual differences between the simulation and the measurements can potentially be attributed to the scattering of scintillation photons inside the materials used. Additional measurements to further advance the construction of the simulation model are suggested.
  •  
9.
  • Knyazev, A., et al. (författare)
  • Tl concentration and its variation in a CsI(Tl) crystal for the CALIFA detector
  • 2020
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 975
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the factors that can contribute to the resolution of long, doped inorganic scintillators used for nuclear spectroscopy is the variation of the dopant concentration over the length the detector crystal. In this work an investigation of such potential variations in one of the CsI(Tl) scintillators used in the calorimeter, CALIFA, of the R3B experiment at FAIR, has been performed using particle induced X-ray emission. No statistically significant gradient in doping level was found along the long axis of the investigated sample crystal and the mean value of the Tl concentration was measured to be 0.0839(38)% by weight. This corresponds to a light output of 97.3−1.7 +1.3% relative to the maximum attainable light output according to previously published work. By taking the ±1σ bounds, the 3% statistical spread in the relative light output provides a good reference value of the minimum light-output non-uniformity observed for the CALIFA crystals. If the relative light output is estimated pointwise from a set of Tl concentration measurements a light-output non-uniformity of 4.6(2.4)% results. For a γ-ray energy of 662 keV the deduced variation in Tl concentration contributes with 0.48(6)% to the typical resolution of 7.74(6)% measured with a collimated source along the crystal main axis. The result is of interest for the characterization of the detector system performance and for realistic simulations of the light collection process in detector systems that are used for nuclear spectroscopy and calorimetry.
  •  
10.
  • Ponnath, L., et al. (författare)
  • Measurement of nuclear interaction cross sections towards neutron-skin thickness determination
  • 2024
  • Ingår i: Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics. - 0370-2693. ; 855
  • Tidskriftsartikel (refereegranskat)abstract
    • The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of [Formula presented] on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R3B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.
  •  
11.
  • Rodriguez-Sancheza, J. L., et al. (författare)
  • Comprehensive investigation of fission yields by using spallation- and (p,2p)induced fission reactions in inverse kinematics
  • 2023
  • Ingår i: 15TH INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, ND2022. - 2100-014X. ; 284
  • Konferensbidrag (refereegranskat)abstract
    • In the last decades, measurements of spallation, fragmentation and Coulex induced fission reactions in inverse kinematics have provided valuable data to accurately investigate the fission dynamics and nuclear structure at large deformations of a large variety of stable and non -stable heavy nuclei. To go a step further, we propose now to induce fission by the use of quasi -free (p,2p) scattering reactions in inverse kinematics, which allows us to reconstruct the excitation energy of the compound fissioning system by using the four-momenta of the two outgoing protons. Therefore, this new approach might permit to correlate the excitation energy with the charge and mass distributions of the fission fragments and with the fission probabilities, given for the first time direct access to the simultaneous measurement of the fission yield dependence on temperature and fission barrier heights of exotic heavy nuclei, respectively. The first experiment based on this methodology was realized recently at the GM/FAIR facility and a detailed description of the experimental setup is given here.
  •  
12.
  • Alvarez-Pol, H., et al. (författare)
  • Performance analysis for the CALIFA Barrel calorimeter of the (RB)-B-3 experiment
  • 2014
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 767, s. 453-466
  • Tidskriftsartikel (refereegranskat)abstract
    • The CALIFA calorimeter is an advanced detector for gamma rays and light charged particles, accordingly optimized for the demanding requirements of the physics programme proposed for the (RB)-B-3 facility at FAIR. The multipurpose character of CALIFA is required to fulfil challenging demands in energy resolution (5-6% at 1 MeV for gamma rays) and efficiency. Charged particles, e.g. protons of energies up to 320 MeV in the Barrel section, should also be identified with an energy resolution better to 1%. CALIFA is divided into two well-separated sections: a "Forward EndCap" and a cylindrical "Barrel" covering an angular range from 43.2 degrees to 140.3 degrees. The Barrel section, based on long CsI(Tl) pyramidal frustum crystals coupled to large area avalanche photodiodes (LAAPDs), attains the requested high efficiency for calorimetric purposes. The construction of the CALIFA Demonstrator, comprising 20% of the total detector, has already been initiated, and commissioning experiments are expected for 2014. The assessment of the capabilities and expected performance of the detector elements is a crucial step in their design, along with the prototypes evaluation. For this purpose, the Barrel geometry has been carefully implemented in the simulation package R3BRoot, including easily variable thicknesses of crystal wrapping and carbon fibre supports. A complete characterization of the calorimeter response (including efficiency, resolution, evaluation of energy and reconstruction losses) under different working conditions, with several physics cases selected to probe the detector performance over a wide range of applications, has been undertaken. Prototypes of different sections of the CALIFA Barrel have been modeled and their responses have been evaluated and compared with the experimental results. The present paper summarizes the outcome of the simulation campaign for the entire Barrel section and for the corresponding prototypes tested at different European installations. (C) 2014 Elsevier B.V. All rights reserved
  •  
13.
  • Cortina-Gil, D., et al. (författare)
  • CALIFA, a Dedicated Calorimeter for the (RB)-B-3/FAIR
  • 2014
  • Ingår i: Nuclear Data Sheets. - : Elsevier BV. - 0090-3752. ; 120, s. 99-101
  • Tidskriftsartikel (refereegranskat)abstract
    • The (RB)-B-3 experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the (RB)-B-3 experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction.
  •  
14.
  • Knyazev, Alexander, et al. (författare)
  • Properties of the CsI(Tl) detector elements of the CALIFA detector
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 940, s. 393-404
  • Tidskriftsartikel (refereegranskat)abstract
    • In the R3B experiment at FAIR, charged particles with energies up to 600 MeV and forward boosted γ-rays with energies up to 20 MeV need to be detected in scattering experiments. Calorimeters for nuclear physics experiments of this kind, using relativistic radioactive ion beams, require high energy resolution and high efficiency for simultaneous detection of strongly Doppler shifted γ-rays and high-energy charged particles. A calorimeter design that can meet these requirements, using CsI(Tl) scintillators, results in detector elements that may exhibit light output variations with crystal depth, which can limit the attainable resolution. In this paper we present results from a systematic study of 478 detector modules of CALIFA, the R3B calorimeter, in order to determine and minimize such variations. To facilitate further systematic studies we also present results for the total absorption length of the scintillation light, using spectrophotometry, light crosstalk between adjacent detector modules, and surface topography of the CsI(Tl) crystals from atomic force microscopy.
  •  
15.
  • Heil, M., et al. (författare)
  • A new Time-of-flight detector for the R 3 B setup
  • 2022
  • Ingår i: European Physical Journal A. - : Springer Science and Business Media LLC. - 1434-601X .- 1434-6001. ; 58:12
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the design, prototype developments and test results of the new time-of-flight detector (ToFD) which is part of the R3B experimental setup at GSI and FAIR, Darmstadt, Germany. The ToFD detector is able to detect heavy-ion residues of all charges at relativistic energies with a relative energy precision σΔE/ ΔE of up to 1% and a time precision of up to 14 ps (sigma). Together with an elaborate particle-tracking system, the full identification of relativistic ions from hydrogen up to uranium in mass and nuclear charge is possible.
  •  
16.
  • Kirchhof, P., et al. (författare)
  • Anticoagulation with Edoxaban in Patients with Atrial High-Rate Episodes
  • 2023
  • Ingår i: New England Journal of Medicine. - : Massachusetts Medical Society. - 0028-4793 .- 1533-4406. ; 389:13, s. 1167-1179
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.)
  •  
17.
  • García-Jiménez, G., et al. (författare)
  • Study of scintillation properties and performance of CsI(Tl) detectors over time
  • 2024
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - 0168-9002. ; 1059
  • Tidskriftsartikel (refereegranskat)abstract
    • This work presents a systematic study of the properties (Light Output Non-Uniformity (LONU) and energy resolution) of two CsI(Tl) scintillation units over a span of almost three years, under adverse conditions of humidity and temperature. These two crystals are part of the CALIFA detector, a highly segmented calorimeter and spectrometer for γ rays and light-charged particles, that is placed surrounding the reaction target at Cave C, the experimental cave of the R3B (Reactions with Radioactive Relativistic Beams) collaboration at the GSI-FAIR facilities in Darmstadt, Germany. The findings obtained after the experiment indicate that there was no significant impact on the performance in terms of resolution and LONU. This suggests that the employed wrapping for light collection effectively serves as an excellent barrier against humidity. As a result, the crystal is preserved in a far better condition than initially anticipated.
  •  
18.
  • Gobel, K., et al. (författare)
  • Coulomb dissociation of 16O into 4He and 12C
  • 2020
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 1668:1
  • Konferensbidrag (refereegranskat)abstract
    • We measured the Coulomb dissociation of 16O into 4He and 12C at the R3B setup in a first campaign within FAIR Phase 0 at GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt. The goal was to improve the accuracy of the experimental data for the 12C(a,?)16O fusion reaction and to reach lower center-ofmass energies than measured so far. The experiment required beam intensities of 109 16O ions per second at an energy of 500 MeV/nucleon. The rare case of Coulomb breakup into 12C and 4He posed another challenge: The magnetic rigidities of the particles are so close because of the same mass-To-charge-number ratio A/Z = 2 for 16O, 12C and 4He. Hence, radical changes of the R3B setup were necessary. All detectors had slits to allow the passage of the unreacted 16O ions, while 4He and 12C would hit the detectors' active areas depending on the scattering angle and their relative energies. We developed and built detectors based on organic scintillators to track and identify the reaction products with sufficient precision.
  •  