SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cheng Yuxin) "

Sökning: WFRF:(Cheng Yuxin)

  • Resultat 1-21 av 21
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
2.
  • Luo, Yifei, et al. (författare)
  • Technology Roadmap for Flexible Sensors
  • 2023
  • Ingår i: ACS Nano. - : American Chemical Society. - 1936-0851 .- 1936-086X. ; 17:6, s. 5211-5295
  • Forskningsöversikt (refereegranskat)abstract
    • Humans rely increasingly on sensors to address grand challenges and to improve quality of life in the era of digitalization and big data. For ubiquitous sensing, flexible sensors are developed to overcome the limitations of conventional rigid counterparts. Despite rapid advancement in bench-side research over the last decade, the market adoption of flexible sensors remains limited. To ease and to expedite their deployment, here, we identify bottlenecks hindering the maturation of flexible sensors and propose promising solutions. We first analyze challenges in achieving satisfactory sensing performance for real-world applications and then summarize issues in compatible sensor-biology interfaces, followed by brief discussions on powering and connecting sensor networks. Issues en route to commercialization and for sustainable growth of the sector are also analyzed, highlighting environmental concerns and emphasizing nontechnical issues such as business, regulatory, and ethical considerations. Additionally, we look at future intelligent flexible sensors. In proposing a comprehensive roadmap, we hope to steer research efforts towards common goals and to guide coordinated development strategies from disparate communities. Through such collaborative efforts, scientific breakthroughs can be made sooner and capitalized for the betterment of humanity.
  •  
3.
  • Cheng, Hongfei, et al. (författare)
  • Can digital transformation change a firm's green innovation strategy? Evidence from China's heavily polluting industries
  • 2024
  • Ingår i: Heliyon. - : CELL PRESS. - 2405-8440. ; 10:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Enterprises are facing the superimposed challenges of digitalization and greening. The shift from reactive green technology innovation (RGT) to proactive green technology innovation (PGT) has special significance for sustainable economic development. Which strategies will companies choose? Can digital transformation (DT) motivate companies to transform their green innovation strategies? Enterprises' green innovation strategy choices must be explained with regard to digitalization. The purpose of this paper is to reveal how digitalization affects the choice of green innovation strategies and to provide a realistic basis for the sustainable development of heavily polluting enterprises. We formulated a "DT -capability -strategy" theoretical framework incorporating external constraints and internal attitudes to empirically test the microdata of 505 heavily polluting enterprises. The results show that: (1) DT can shift the heavily polluting enterprises' green innovation strategies from RGT to PGT. Endogenous tests and robustness tests support this conclusion. (2) A mechanism test shows that environmental regulations cannot significantly regulate a green innovation strategy. Only a company's capabilities and attitudes can influence PGT but their effects on RGT are not statistically significant. (3) The influence of DT on green innovation strategies shows multi -dimensional heterogeneity in the digital infrastructure, scale, and innovation level of the enterprise. The conclusions provide implications for enterprises to integrate their digital and green behaviors.
  •  
4.
  • Cheng, Yuxin, et al. (författare)
  • Centralized Control Plane for Passive Optical Top-of-Rack Interconnects in Data Centers
  • 2016
  • Ingår i: 2016 IEEE Global Communications Conference, GLOBECOM 2016 - Proceedings. - : IEEE conference proceedings. - 9781509013289
  • Konferensbidrag (refereegranskat)abstract
    • To efficiently handle the fast growing traffic inside data centers, several optical interconnect architectures have been recently proposed. However, most of them are targeting the aggregation and core tiers of the data center network, while relying on conventional electronic top-of-rack (ToR) switches to connect the servers inside the rack. The electronic ToR switches pose serious limitations on the data center network in terms of high cost and power consumption. To address this problem, we recently proposed a passive optical top-of-rack interconnect architecture, where we focused on the data plane design utilizing simple passive optical components to interconnect the servers within the rack. However, an appropriate control plane tailored for this architecture is needed to be able to analyze the network performance, e.g., packet delay, drop rate, etc., and also obtain a holistic network design for our passive optical top-of-rack interconnect, which we refer to as POTORI. To fill in this gap, this paper proposes the POTORI control plane design which relies on a centralized rack controller to manage the communications inside the rack. To achieve high network performance in POTORI, we also propose a centralized medium access control (MAC) protocol and two dynamic bandwidth allocation (DBA) algorithms, namely Largest First (LF) and Largest First with Void Filling (LFVF). Simulation results show that POTORI achieves packet delays in the order of microseconds and negligible packet loss probability under realistic data center traffic scenarios.
  •  
5.
  • Cheng, Yuxin (författare)
  • Optical Interconnects for Next Generation Data Centers : Architecture Design and Resource Allocation
  • 2019
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The current data center architectures based on blade servers and elec- tronic packet switches face several problems, e.g., limited resource utilization, high power consumption and cost, when handling the rapidly growing of data traffic. Optical networks offering ultra-high capacity and requiring low energy consumption are considered as a good option to address these problems. This thesis presents new data center architectures based on optical interconnects and transmissions, and evaluates performance by extensive simulations.The first main contribution of the thesis is to introduce a passive optical top-of-rack interconnect (POTORI) architecture. The data plane of POTORI mainly consists of passive components to interconnect the servers within the rack. Using the passive components makes it possible to significantly reduce power consumption while achieving high reliability in a cost-efficient way. In addition, the POTORI’s control plane is based on a centralized controller, which is responsible for coordinating the communications among the servers in the rack. A cycle-based medium access control (MAC) protocol and a dy- namic bandwidth allocation (DBA) algorithm are designed for the POTORI to efficiently manage the exchange of control messages and the data transmis- sion inside the rack. Simulation results show that under realistic DC traffic scenarios, the POTORI with the proposed DBA algorithm is able to achieve an average packet delay below 10 μs with the use of fast tunable optical transceivers.The second main contribution of the thesis is to investigate rack-scale disaggregated data center (DDC) architecture for improving resource utiliza- tion. In contrast to the traditional DC with blade servers that integrate various types of resources (e.g., central processing unit (CPU), memory) in a chassis, the rack-scale DDC contains fully decoupled resources held on differ- ent blades, referred to as resource blades. The resource blades are required to be interconnected within the rack by an ultra-high bandwidth optical in- terconnect through the optical interfaces (OIs). A resource allocation (RA) algorithm is proposed to efficiently schedule the resources in the DDC for virtual machine requests. Results show that with sufficient bandwidth on the OIs, the rack-scale DDC with the proposed RA algorithm can achieve 20% higher resource utilization and make 30% more revenue comparing to the traditional DC.
  •  
6.
  • Cheng, Yuxin (författare)
  • Passive Optical Top-of-Rack Interconnect for Data Center Networks
  • 2017
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Optical networks offering ultra-high capacity and low energy consumption per bit are considered as a good option to handle the rapidly growing traffic volume inside data center (DCs). However, most of the optical interconnect architectures proposed for DCs so far are mainly focused on the aggregation/core tiers of the data center networks (DCNs), while relying on the conventional top-of-rack (ToR) electronic packet switches (EPS) in the access tier. A large number of ToR switches in the current DCNs brings serious scalability limitations due to high cost and power consumption. Thus, it is important to investigate and evaluate new optical interconnects tailored for the access tier of the DCNs.We propose and evaluate a passive optical ToR interconnect (POTORI) architecture for the access tier. The data plane of the POTORI consists mainly of passive components to interconnect the servers within the rack as well as the interfaces toward the aggregation/core tiers. Using the passive components makes it possible to significantly reduce power consumption while achieving high reliability in a cost-efficient way.Meanwhile, our proposed POTORI’s control plane is based on a centralized rack controller, which is responsible for coordinating the communications among the servers in the rack. It can be reconfigured by software-defined networking (SDN) operation. A cycle-based medium access control (MAC) protocol and a dynamic bandwidth allocation (DBA) algorithm are designed for the POTORI to efficiently manage the exchange of control messages and the data transmission inside the rack.Simulation results show that under realistic DC traffic scenarios, the POTORI with the proposed DBA algorithm is able to achieve an average packet delay below 10 μs with the use of fast tunable optical transceivers. Moreover, we further quantify the impact of different network configuration parameters on the average packet delay. 
  •  
7.
  • Cheng, Yuxin, et al. (författare)
  • POTORI : A Passive Optical Top-of-Rack Interconnect Architecture for Data Centers
  • 2017
  • Ingår i: Journal of Optical Communications and Networking. - : Institute of Electrical and Electronics Engineers (IEEE). - 1943-0620 .- 1943-0639. ; 9:5, s. 401-411
  • Tidskriftsartikel (refereegranskat)abstract
    • Several optical interconnect architectures inside data centers (DCs) have been proposed to efficiently handle the rapidly growing traffic demand. However, not many works have tackled the interconnects at top-of-rack (ToR), which have a large impact on the performance of the data center networks (DCNs) and can introduce serious scalability limitations due to their high cost and power consumption. In this paper, we propose a passive optical ToR interconnect architecture (POTORI) to replace the conventional electronic packet switch (EPS) in the access tier of DCNs. In the data plane, POTORI relies on a passive optical coupler to interconnect the servers within the rack and interfaces toward the aggregation/core tiers. The POTORI control plane is based on a centralized rack controller responsible for managing the communications among the servers in the rack. We propose a cycle-based medium access control (MAC) protocol to efficiently manage the exchange of control messages and the data transmission inside the rack. We also introduce and evaluate a dynamic bandwidth allocation algorithm for POTORI, namely largest first (LF). Extensive simulation results show that, with the use of fast tunable optical transceivers, POTORI and the proposed LF strategy are able to achieve an average packet delay below 10 μs under realistic DC traffic scenarios, outperforming conventional EPSs. On the other hand, with slower tunable optical transceivers, a careful configuration of the network parameters (e.g., maximum cycle time of the MAC protocol) is necessary to obtain a good network performance in terms of the average packet delay.
  •  
8.
  • Cheng, Yuxin, et al. (författare)
  • Reliability Analysis of Interconnects at Edge Tier in Datacenters
  • 2015
  • Ingår i: 2015 17th International Conference on Transparent Optical Networks (ICTON). - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467378802
  • Konferensbidrag (refereegranskat)abstract
    • The growing popularity of cloud based applications is drastically increasing the traffic volume that datacenters have to handle. This brings the need for scalable, reliable, and energy-efficient interconnection networks inside the datacenters. Optical communication has been considered as a promising technology for datacenter applications due to its high energy- and cost-efficiency at ultra-high capacity. A typical datacenter interconnection network includes several tiers. Figure 1 shows an example with three tiers: edge, aggregation and core. Due to the large number of active devices on top of the rack (ToR) energy consumption at the edge tier is dominating the overall power consumed by all the switches within the datacenter [1-2]. Several passive optical interconnect approaches [2-4] have been proposed showing that replacing active optical devices by passive ones is possible to significantly reduce both the hardware cost and energy consumption, achieve lower maintenance complexity and offer a sufficient level of scalability. [GRAPHICS] Furthermore, several topologies, e.g., fat-tree [5], Quartz [6], are investigated in order to improve the resiliency and scalability, particularly for large-scale datacenters. However, it should be noted that the redundancy for these proposed topologies is often added in the aggregation and core tiers rather than the edge tier, due to the cost issue. Although passive optical ToR solution by nature could provide better reliability performance than its active counterpart, the intra-rack communication may still need survivability strategies to meet very high connection availability requirement. For instance, the required availability of fault-tolerant datacenter infrastructure (including electrical power supply, storage and distribution facilities) should be higher than 99.995% [7]. Then the expected availability for any connection established within the datacenter needs to be even higher, since the communication system is only a part of the site infrastructure. In this regard, we analyse reliability performance of optical interconnects and identify the key part to be protected. Based on it, we propose some reliable passive optical interconnects for the edge tier of the datacenter interconnection networks. They can achieve ultra-high connection availability for intra-rack communications and adapt to any topology, e.g., fat-tree and Quartz, designed to increase scalability and reliability performance for the overall datacenter network.
  •  
9.
  • Cheng, Yuxin, et al. (författare)
  • Reliable and Cost Efficient Passive Optical Interconnects for Data Centers
  • 2015
  • Ingår i: IEEE Communications Letters. - : IEEE Communications Society. - 1089-7798 .- 1558-2558. ; 19:11, s. 1913-1916
  • Tidskriftsartikel (refereegranskat)abstract
    • To address the sustainability, scalability, and reliability problems that data centers are currently facing, we propose three passive optical interconnect (POI) architectures on top of the rack. The evaluation results show that all three architectures offer high reliability performance (connection availability for intra-rack interconnections higher than 99.999%) in a cost-efficient way.
  •  
10.
  •  
11.
  • Kong, Xiangrui, et al. (författare)
  • Impact of SO2 and light on chemical morphology and hygroscopicity of natural salt aerosols
  • 2024
  • Ingår i: Atmospheric Environment. - 1352-2310 .- 1873-2844. ; 322
  • Tidskriftsartikel (refereegranskat)abstract
    • The interactions between SO2 and natural salt aerosol particles represent complex and crucial dynamics within atmospheric processes and the broader climate system. This study investigated the SO2 uptake, hygroscopicity, morphology and mixing states of natural salt particles, which are generated from brines sampled from the Chaka salt lake located in the Qinghai-Tibet plateau. A comparison with atomized pure NaCl particles is included as reference. The results show that NaCl particles exhibit the lowest SO2 uptake, while Chaka salt particles demonstrate higher uptake due to their complex composition. The hygroscopicity of salt particles is influenced by several factors, including chemical complexity, SO2 exposure and light conditions. In comparison to pure NaCl, Chaka salt displays higher hygroscopicity, which is further enhanced in the presence of SO2. However, when exposed to light, mass growth is suppressed, suggesting the formation of species with lower hygroscopicity, such as Na2SO4. Analysis of particle morphology and mixing states reveals notable distinctions between NaCl crystals and Chaka salt particles, where the Chaka salt particles exhibit rounded shapes with a structure composed of cubic NaCl cores surrounded by sulfate materials as a coating. In addition, the chemical morphology analysis also reveals that the particles show morphological and spectral changes before and after the exposure to SO2, light and high RH. Therefore, this research highlights the intricate interactions between SO2 and natural salt aerosol particles in diverse environmental settings, underscoring their multifaceted impacts on atmospheric processes.
  •  
12.
  • Lin, Rui, et al. (författare)
  • Disaggregated Data Centers : Challenges and Tradeoffs
  • 2019
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Resource utilization of modern data centers is significantly limited by the mismatch between the diversity of the resources required by running applications and the fixed amount of hardwired resources (e.g., number of central processing unit CPU cores, size of memory) in the server blades. In this regard, the concept of function disaggregation is introduced, where the integrated server blades containing all types of resources are replaced by the resource blades including only one specific function. Therefore, disaggregated data centers can offer high flexibility for resource allocation and hence their resource utilization can be largely improved. In addition, introducing function disaggregation simplifies the system upgrade, allowing for a quick adoption of new generation components in data centers. However, the communication between different resources faces severe problems in terms of latency and transmission bandwidth required. In particular,the CPU-memory interconnects in fully disaggregated data centers require ultra-low latency and ultra-high transmission bandwidth in order to prevent performance degradation for running applications. Optical fiber communication is a promising technique to offer high capacity and low latency, but it is still very challenging for the state-of-the-art optical transmission technologies to meet the requirements of the fully disaggregated data centers. In this paper, different levels of function disaggregation are investigated. For the fully disaggregated data centers, two architectural options are presented, where optical interconnects are necessary for CPU-memory communications. We review the state-of-the-art optical transmission technologies and carry out performance assessment when employing them to support function disaggregation in data centers. The results reveal that function disaggregation does improve the efficiency of resource usage in the data centers, although the bandwidth provided by the state-of-the-art optical transmission technologies is not always sufficient for the fully disaggregated data centers. It calls for research in optical transmission to fully utilize the advantages of function disaggregation in data centers.
  •  
13.
  • Lin, Rui, 1988, et al. (författare)
  • Disaggregated Data Centers: Challenges and Trade-offs
  • 2020
  • Ingår i: IEEE Communications Magazine. - : Institute of Electrical and Electronics Engineers (IEEE). - 0163-6804 .- 1558-1896. ; 58:2, s. 20-26
  • Tidskriftsartikel (refereegranskat)abstract
    • Disaggregated data centers (DCs) can offer high flexibility for resource allocation; hence, their resource utilization can be significantly improved. However, communications between different types of resources, in particular between CPU and memory, in fully disaggregated DCs face severe problems in terms of stringent requirements for ultra-low latency and ultra-high transmission bandwidth. Optical fiber communication is promising to provide high capacity and low latency, but it is still challenging for the state-of-the-art optical technologies to meet the requirements of fully disaggregated DCs. In this article, different levels of resource disaggregation are investigated. For fully disaggregated DCs, two architectural options are presented, where optical interconnects are necessary for the CPU-memory communications. We review the state-of-the-art optical transmission and switching technologies, and analyze pros and cons of their applicability in the disaggregated DCs. The results reveal that resource disaggregation does improve the resource utilization in DCs. However, the bandwidth provided by the state-of-the-art technologies is not always sufficient for fully disaggregated DCs. It calls for further advances in optical communications to fully utilize the advantages of fully disaggregated DCs.
  •  
14.
  •  
15.
  • Lin, Rui, et al. (författare)
  • Physical-layer network coding for passive optical interconnect in datacenter networks
  • 2017
  • Ingår i: Optics Express. - 1094-4087. ; 25:15, s. 17788-17797
  • Tidskriftsartikel (refereegranskat)abstract
    • We introduce physical-layer network coding (PLNC) technique in a passive optical interconnect (POI) architecture for datacenter networks. The implementation of the PLNC in the POI at 2.5 Gb/s and 10Gb/s have been experimentally validated while the gains in terms of network layer performances have been investigated by simulation. The results reveal that in order to realize negligible packet drop, the wavelengths usage can be reduced by half while a significant improvement in packet delay especially under high traffic load can be achieved by employing PLNC over POI.
  •  
16.
  • Lin, Rui, et al. (författare)
  • Physical-layer network coding for passive optical interconnects in datacenter networks
  • 2017
  • Ingår i: 2017 19th International Conference on Transparent Optical Networks (ICTON). - : IEEE Computer Society. - 9781538608586
  • Konferensbidrag (refereegranskat)abstract
    • We introduce physical-layer network coding for a passive optical interconnect architecture in datacenter networks. Results reveal that half of the wavelengths can be saved to obtain latency in the magnitude of microseconds.
  •  
17.
  • Lu, Yang, et al. (författare)
  • Matrix Receiving Scheme Supporting Arbitrary Multiple-Wavelength Reception for Optical Interconnects
  • 2017
  • Ingår i: European Conference on Optical Communication, ECOC. - : IEEE. - 9781538656242
  • Konferensbidrag (refereegranskat)abstract
    • An arbitrary multiple-wavelength reception scheme using only a few fixed-wavelength filters is proposed for optical interconnects. Filter matrices design based on error-control coding theory is devised. The feasibility of the proposed scheme is demonstrated in a four-wavelength reception experiment.
  •  
18.
  • Lu, Yang, et al. (författare)
  • Multi-channel collision-free reception for optical interconnects
  • 2018
  • Ingår i: Optics Express. - : OPTICAL SOC AMER. - 1094-4087. ; 26:10, s. 13214-13222
  • Tidskriftsartikel (refereegranskat)abstract
    • A multi-channel reception scheme that allows each node to receive an arbitrary set of wavelengths simultaneously (i.e., collision-free) is proposed for optical interconnects. The proposed scheme only needs to use a few receivers and fixed-wavelength filters that are designed based on error-control coding theory. Experiments with up to four channel collision-free reception units are carried out to demonstrate the feasibility of the proposed scheme.
  •  
19.
  • Pang, Z., et al. (författare)
  • Preliminary study on wireless home automation systems with both cloud-based mode and stand-alone mode
  • 2015
  • Ingår i: Proceedings - 17th IEEE International Conference on Computational Science and Engineering, CSE 2014, Jointly with 13th IEEE International Conference on Ubiquitous Computing and Communications, IUCC 2014, 13th International Symposium on Pervasive Systems, Algorithms, and Networks, I-SPAN 2014 and 8th International Conference on Frontier of Computer Science and Technology, FCST 2014. - 9781479979813 ; , s. 970-975
  • Konferensbidrag (refereegranskat)abstract
    • As the Smart Home segment is an intersection of numerous industries including consumer electronics, telecom, internet, and building automation, a Home Automation (HA) system requires flexible wireless communication architecture to not only take the advantages of wireless technologies such as reduced cost of installation and maintenance and improved user experiences but also fulfill the concerns of various industrial stakeholders. From this point-of-view, neither the pure Cloud-Based nor the Stand-Alone architecture is sufficient. In this paper, an IP-based hybrid architecture is presented which can support flexible combination of Could-Based Mode and Stand-Alone Mode. Preliminary prototyping based on the 6LoWPAN and experimental evaluation of performances have indicated the technical feasibility as well as future directions of improvement.
  •  
20.
  • Pang, Z., et al. (författare)
  • Work-in-progress : Industry-friendly and native-IP wireless communications for building automation
  • 2015
  • Ingår i: Proceedings of the 2015 1st International Conference on Industrial Networks and Intelligent Systems, INISCom 2015. - : IEEE conference proceedings. - 9781631900228 ; , s. 163-167
  • Konferensbidrag (refereegranskat)abstract
    • Wireless communication technologies for building automation (BA) systems are evolving towards native IP connectivity. More Industry Friendly and Native-IP Wireless Building Automation (IF-NIP WiBA) is needed to address the concerns of the entire value chain of the BA industry including the security, reliability, latency, power consumption, engineering process, and independency. In this paper, a hybrid architecture which can seamless support both Cloud-Based Mode and Stand-Alone Mode is introduced based on the 6LoWPAN WSAN (wireless sensor and actuator networks) technology and verified by a prototyping minimal system. The preliminary experimental results suggest that, 1) both the WSAN and Cloud communications can meet the requirements of non-real-time application of BA systems, 2) the reliability and latency of the WSAN communications is not sufficient for soft real-time applications but it is not far away to meet such requirements by sufficient optimization in the near future, 3) the reliability of Cloud is pretty sufficient but the latency is quite far from the requirement of soft real-time applications. To optimize the latency and power consumption in WSAN, design industrial friendly engineering process, and investigate security mechanisms should be the main focus in the future.
  •  
21.
  • Wosinska, Lena, 1951-, et al. (författare)
  • Optical Network Architectures and Technologies for Datacenters
  • 2017
  • Ingår i: 2017 IEEE PHOTONICS SOCIETY SUMMER TOPICAL MEETING SERIES (SUM). - : IEEE. - 9781509065714 ; , s. 111-112
  • Konferensbidrag (refereegranskat)abstract
    • The paper highlights the challenges related to the increasing importance of datacenter services, leading to dramatically growing datacenter traffic. The advantages of using photonic technology in intra-datacenter networks are discussed and a cross-layer view for network architecture design is presented.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-21 av 21

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy