SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Julkunen Petro) "

Sökning: WFRF:(Julkunen Petro)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Julkunen, Petro, et al. (författare)
  • A Review of the Combination of Experimental Measurements and Fibril-Reinforced Modeling for Investigation of Articular Cartilage and Chondrocyte Response to Loading
  • 2013
  • Ingår i: Computational & Mathematical Methods in Medicine. - : Hindawi Limited. - 1748-6718 .- 1748-670X.
  • Forskningsöversikt (refereegranskat)abstract
    • The function of articular cartilage depends on its structure and composition, sensitively impaired in disease (e. g. osteoarthritis, OA). Responses of chondrocytes to tissue loading are modulated by the structure. Altered cell responses as an effect of OA may regulate cartilage mechanotransduction and cell biosynthesis. To be able to evaluate cell responses and factors affecting the onset and progression of OA, local tissue and cell stresses and strains in cartilage need to be characterized. This is extremely challenging with the presently available experimental techniques and therefore computational modeling is required. Modern models of articular cartilage are inhomogeneous and anisotropic, and they include many aspects of the real tissue structure and composition. In this paper, we provide an overview of the computational applications that have been developed for modeling the mechanics of articular cartilage at the tissue and cellular level. We concentrate on the use of fibril-reinforced models of cartilage. Furthermore, we introduce practical considerations for modeling applications, including also experimental tests that can be combined with the modeling approach. At the end, we discuss the prospects for patient-specific models when aiming to use finite element modeling analysis and evaluation of articular cartilage function, cellular responses, failure points, OA progression, and rehabilitation.
  •  
2.
  • Julkunen, Petro, et al. (författare)
  • Biomechanical, biochemical and structural correlations in immature and mature rabbit articular cartilage.
  • 2009
  • Ingår i: Osteoarthritis and Cartilage. - : Saunders Elsevier. - 1063-4584 .- 1522-9653. ; 17:12, s. 1628-1638
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The structure and composition of articular cartilage change during development and growth. These changes lead to alterations in the mechanical properties of cartilage. In the present study, biomechanical, biochemical and structural relationships of articular cartilage during growth and maturation of rabbits are investigated.DESIGN: Articular cartilage specimens from the tibial medial plateaus and femoral medial condyles of female New Zealand white rabbits were collected from seven age-groups; 0 days (n=29), 11 days (n=30), 4 weeks (n=30), 6 weeks (n=30), 3 months (n=24), 6 months (n=24) and 18 months (n=19). The samples underwent mechanical testing under creep indentation. From the mechanical response, instantaneous and equilibrium moduli were determined. Biochemical analyses of tissue collagen, hydroxylysylpyridinoline (HP) and pentosidine (PEN) cross-links in full thickness cartilage samples were conducted. Proteoglycans were investigated depth-wise from the tissue sections by measuring the optical density of Safranin-O-stained samples. Furthermore, depth-wise collagen architecture of articular cartilage was analyzed with polarized light microscopy. Finite element analyses of the samples from different age-groups were conducted to reveal tensile and compressive properties of the fibril network and the matrix of articular cartilage, respectively.RESULTS: Tissue thickness decreased from approximately 3 to approximately 0.5mm until the age of 3 months, while the instantaneous modulus increased with age prior to peak at 4-6 weeks. A lower equilibrium modulus was observed before 3-month-age, after which the equilibrium modulus continued to increase. Collagen fibril orientation angle and parallelism index were inversely related to the instantaneous modulus, tensile fibril modulus and tissue thickness. Collagen content and cross-linking were positively related to the equilibrium compressive properties of the tissue.CONCLUSIONS: During maturation, significant modulation of tissue structure, composition and mechanical properties takes place. Importantly, the present study provides insight into the mechanical, chemical and structural interactions that lead to functional properties of mature articular cartilage.
  •  
3.
  • Julkunen, Petro, et al. (författare)
  • Stress-relaxation of human patellar articular cartilage in unconfined compression : prediction of mechanical response by tissue composition and structure.
  • 2008
  • Ingår i: Journal of Biomechanics. - : Elsevier. - 0021-9290 .- 1873-2380. ; 41:9, s. 1978-86
  • Tidskriftsartikel (refereegranskat)abstract
    • Mechanical properties of articular cartilage are controlled by tissue composition and structure. Cartilage function is sensitively altered during tissue degeneration, in osteoarthritis (OA). However, mechanical properties of the tissue cannot be determined non-invasively. In the present study, we evaluate the feasibility to predict, without mechanical testing, the stress-relaxation response of human articular cartilage under unconfined compression. This is carried out by combining microscopic and biochemical analyses with composition-based mathematical modeling. Cartilage samples from five cadaver patellae were mechanically tested under unconfined compression. Depth-dependent collagen content and fibril orientation, as well as proteoglycan and water content were derived by combining Fourier transform infrared imaging, biochemical analyses and polarized light microscopy. Finite element models were constructed for each sample in unconfined compression geometry. First, composition-based fibril-reinforced poroviscoelastic swelling models, including composition and structure obtained from microscopical and biochemical analyses were fitted to experimental stress-relaxation responses of three samples. Subsequently, optimized values of model constants, as well as compositional and structural parameters were implemented in the models of two additional samples to validate the optimization. Theoretical stress-relaxation curves agreed with the experimental tests (R=0.95-0.99). Using the optimized values of mechanical parameters, as well as composition and structure of additional samples, we were able to predict their mechanical behavior in unconfined compression, without mechanical testing (R=0.98). Our results suggest that specific information on tissue composition and structure might enable assessment of cartilage mechanics without mechanical testing.
  •  
4.
  • Khayyeri, Hanifeh, et al. (författare)
  • A Fibre-Reinforced Poroviscoelastic Model Accurately Describes the Biomechanical Behaviour of the Rat Achilles Tendon
  • 2015
  • Ingår i: PLOS ONE. - : Public Library of Science. - 1932-6203. ; 10:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendons biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally. Materials and Methods We developed a new material model of the Achilles tendon, which considers the tendons main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output. Results and Conclusions All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendons viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons.
  •  
5.
  • Lötjönen, Pauno, et al. (författare)
  • Strain-dependent modulation of ultrasound speed in articular cartilage under dynamic compression.
  • 2009
  • Ingår i: Ultrasound in Medicine and Biology. - : Elsevier. - 1879-291X .- 0301-5629. ; 35:7, s. 1177-1184
  • Tidskriftsartikel (refereegranskat)abstract
    • Mechanical properties of articular cartilage may be determined by means of mechano-acoustic indentation, a clinically feasible technique for cartilage diagnostics. Unfortunately, ultrasound speed varies in articular cartilage during mechanical compression. This can cause significant errors to the measured mechanical parameters. In this study, the strain-dependent variation in ultrasound speed was investigated during dynamic compression. In addition, we estimated errors that were induced by the variation in ultrasound speed on the mechano-acoustically measured elastic properties of the tissue. Further, we validated a computational method to correct these errors. Bovine patellar cartilage samples (n = 7) were tested under unconfined compression. Strain-dependence of ultrasound speed was determined under different compressive strains using an identical strain-rate. In addition, the modulation of ultrasound speed was simulated using the transient compositional and structural changes derived from fibril-reinforced poroviscoelastic (FRPVE) model. Experimentally, instantaneous compressive strain modulated the ultrasound speed (p < 0.05) significantly. The decrease of ultrasound speed was found to change nonlinearly as a function of strain. Immediately after the ramp loading ultrasound speed was found to be changed -0.94%, -1.49%, -1.84%, -1.87%, -1.89% and -2.15% at the strains of 2.4%, 4.9%, 7.3%, 9.7%, 12.1% and 14.4%, respectively. The numerical simulation revealed that the compression-related decrease in ultrasound speed induces significant errors in the mechano-acoustically determined strain (39.7%) and dynamic modulus (72.1%) at small strains, e.g., at 2.4%. However, at higher strains, e.g., at 14.4%, the errors were smaller, i.e., 12.6% for strain and 14.5% for modulus. After the proposed computational correction, errors related to ultrasound speed were decreased. By using the correction, with e.g., 2.4% strain, errors in strain and modulus were decreased from 39.7% to 7.2% and from 72.1% to 35.3%, respectively. The FRPVE model, addressing the changes in fibril orientation and void ratio during compression, showed discrepancy of less than 1% between the predicted and measured ultrasound speed during the ramp compression.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy