1.
  • Granfeldt, Hans, et al. (författare)
  • Risk Factor Analysis of Swedish Left Ventricular Assist Device (LVAD) Patients
  • 2003
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier. - 0003-4975 .- 1552-6259. ; 76:6, s. 1993-1998
  • Tidskriftsartikel (refereegranskat)abstract
    • Background. The use of left ventricular assist devices (LVADs) is established as a bridge to heart transplantation. Methods. All Swedish patients on the waiting list for heart transplantation, treated with LVAD since 1993 were retrospectively collected into a database and analyzed in regards to risk factors for mortality and morbidity. Results. Fifty-nine patients (46 men) with a median age of 49 years (range, 14 to 69 years), Higgins score median of 9 (range, 3 to 15), EuroScore median of 10 (range, 5 to 17) were investigated. Dominating diagnoses were dilated cardiomyopathy in 61% (n = 36) and ischemic cardiomyopathy in 18.6% (n = 11). The patients were supported with LVAD for a median time of 99.5 days (range, 1 to 873 days). Forty-five (76%) patients received transplants, and 3 (5.1%) patients were weaned from the device. Eleven patients (18.6%) died during LVAD treatment. Risk factor analysis for mortality before heart transplantation showed significance for a high total amount of autologous blood transfusions (p < 0.001), days on mechanical ventilation postoperatively (p < 0.001), prolonged postoperative intensive care unit stay (p = 0.007), and high central venous pressure 24 hours postoperatively and at the final measurement (p = 0.03 and 0.01, respectively). Mortality with LVAD treatment was 18.6% (n = 11). High C-reactive protein (p = 0.001), low mean arterial pressure (p = 0.03), and high cardiac index (p = 0.03) preoperatively were risk factors for development of right ventricular failure during LVAD treatment. Conclusions. The Swedish experience with LVAD as a bridge to heart transplantation was retrospectively collected into a database. This included data from transplant and nontransplant centers. Figures of mortality and morbidity in the database were comparable to international experience. Specific risk factors were difficult to define retrospectively as a result of different protocols for follow-up among participating centers. © 2003 by The Society of Thoracic Surgeons.
  •  
2.
  • Al-Rashidi, Faleh, et al. (författare)
  • A new de-airing technique that reduces systemic microemboli during open surgery: a prospective controlled study.
  • 2009
  • Ingår i: The Journal of thoracic and cardiovascular surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 138:1, s. 157-162
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We have evaluated a new technique of cardiac de-airing that is aimed at a) minimizing air from entering into the pulmonary veins by opening both pleurae and allowing lungs to collapse and b) flushing out residual air from the lungs by staged cardiac filling and lung ventilation. These air emboli are usually trapped in the pulmonary veins and may lead to ventricular dysfunction, life-threatening arrhythmias, and transient or permanent neurologic deficits. METHODS: Twenty patients undergoing elective true left open surgery were prospectively and alternately enrolled in the study to the conventional de-airing technique (pleural cavities unopened, dead space ventilation during cardiopulmonary bypass [control group]) and the new de-airing technique (pleural cavities open, ventilator disconnected during cardiopulmonary bypass, staged perfusion, and ventilation of lungs during de-airing [study group]). Transesophageal echocardiography and transcranial Doppler continually monitored the air emboli during the de-airing period and for 10 minutes after termination of the cardiopulmonary bypass. RESULTS: The amount of air embolism as observed on echocardiography and the number of microembolic signals as recorded by transcranial Doppler were significantly less in the study group during the de-airing time (P < .001) and the first 10 minutes after termination of cardiopulmonary bypass (P < .001). Further, the de-airing time was significantly shorter in the study group (10 vs 17 minutes, P < .001). CONCLUSION: The de-airing technique evaluated in this study is simple, reproducible, controlled, safe, and effective. Moreover, it is cost-effective because the de-airing time is short and no extra expenses are involved.
  •  
3.
  • Al Rashidi, Faleh, et al. (författare)
  • Comparison of the effectiveness and safety of a new de-airing technique with a standardized carbon dioxide insufflation technique in open left heart surgery: A randomized clinical trial.
  • 2011
  • Ingår i: The Journal of thoracic and cardiovascular surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; okt, s. 1128-1133
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We have compared the effectiveness, time required for de-airing, and safety of a newly developed de-airing technique for open left heart surgery (Lund technique) with a standardized carbon dioxide insufflation technique. METHODS: Twenty patients undergoing elective open aortic valve surgery were randomized prospectively to the Lund technique (Lund group, n = 10) or the carbon dioxide insufflation technique (carbon dioxide group, n = 10). Both groups were monitored intraoperatively during de-airing and for 10 minutes after weaning from cardiopulmonary bypass by transesophageal echocardiography and online transcranial Doppler for the severity and the number of gas emboli, respectively. The systemic arterial partial pressure of carbon dioxide and pH were also monitored in both groups before, during, and after cardiopulmonary bypass. RESULTS: The severity of gas emboli observed on transesophageal echocardiography and the number of microembolic signals recorded by transcranial Doppler were significantly lower in the Lund group during the de-airing procedure (P = .00634) and in the first 10 minutes after weaning from cardiopulmonary bypass (P = .000377). Furthermore, the de-airing time was significantly shorter in the Lund group (9 vs 15 minutes, P = .001). The arterial pH during the cooling phase of cardiopulmonary bypass was significantly lower in the carbon dioxide group (P = .00351), corresponding to significantly higher arterial partial pressure of carbon dioxide (P = .005196) despite significantly higher gas flows (P = .0398) in the oxygenator throughout the entire period of cardiopulmonary bypass. CONCLUSIONS: The Lund de-airing technique is safer, simpler, and more effective compared with the carbon dioxide insufflation technique. The technique is also more cost-effective because the de-airing time is shorter and no extra expenses are incurred.
  •  
4.
  • Al Rashidi, Faleh, et al. (författare)
  • The modified Ross operation using a Dacron prosthetic vascular jacket does prevent pulmonary autograft dilatation at 4.5-year follow-up.
  • 2010
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940. ; 37, s. 928-933
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Following the Ross operation, pulmonary autografts tend to dilate over time. This study researches the fate of the pulmonary autograft - at 4.5 years following the modified Ross operation - with special reference to the impact of the modification on (a) pulmonary autograft dilatation, (b) the neo-aortic root geometry, (c) neo-aortic valve function and (d) the coronary artery reserve. Methods: A total of 26 patients who underwent the Ross operation were included in this study; of these, 13 consecutive patients underwent a modified Ross operation in which the free-standing autograft root was supported externally by a Dacron vascular prosthetic jacket (DVPJ). These patients were compared to a cohort of 13 matched patients who were operated on using the conventional Ross technique; all patients were followed up prospectively by echocardiography studies. The patients who underwent the modified Ross operation were also subjected to bicycle ergometry. Results: At the 47-month median follow-up, there was no significant increase in the size of the entire neo-aortic root in the patients who underwent the modified Ross operation; in addition, the geometry of the neo-aortic root was also preserved and the left ventricular function had improved significantly, whilst the aortic valve function and excursion remained satisfactory. All patients, with one exception, in the modified Ross operation group exhibited normal exercise capacity. By contrast, there were significant differences in diameters of the aortic root - between the two surgical techniques in favour of the modified Ross technique - following a median follow-up of 23 months in the patients subjected to the conventional Ross operation. Conclusions: Provision of external support to the entire pulmonary autograft with a DVPJ prevents its dilatation following free-standing pulmonary autograft Ross operation when evaluated at the 4.5-year follow-up. The function and the geometry of the neo-aortic root are not affected negatively by this modification and the patients demonstrated normal exercise capacity.
  •  
5.
  • Bjursten, Henrik, et al. (författare)
  • Giant aneurysm in the sinus of Valsalva presenting as an acute coronary symptom.
  • 2013
  • Ingår i: Interactive Cardiovascular and Thoracic Surgery. - : Oxford University Press (OUP). - 1569-9285 .- 1569-9293. ; 17:1, s. 193-195
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe an 85-year old male who was admitted to the hospital with acute coronary symptoms. Bedside echocardiography revealed a structure in the aortic root, and a computed tomography scan verified the diagnosis of an aneurysm in the sinus of Valsalva below the left coronary ostium. A coronary angiography also depicted the aneurysm clearly and clearly showed how the aneurysm compressed and dislocated the left main coronary artery, explaining his initial symptoms. The patient was operated on with an aortic root replacement procedure, and recovered quickly.
  •  
6.
  •  
7.
  • Bućin, Dragan, et al. (författare)
  • Desensitization and Heart Transplantation of a Patient With High Levels of Donor-Reactive Anti-Human Leukocyte Antigen Antibodies.
  • 2010
  • Ingår i: Transplantation. - 1534-6080. ; 90, s. 1220-1225
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND.: To prepare a highly immunized recipient for heart transplantation, reduction of high levels of cytotoxic antibodies against human leukocyte antigen (HLA) was deemed essential to prevent antibody-mediated graft failure. METHODS.: Antibodies were analyzed by lymphocytotoxic and solid-phase assays. The pretransplant desensitization treatment protocol included daily tacrolimus and mycophenolate mofetil, weekly protein-A immunoadsorption (IA), intravenous immunoglobulin, and daclizumab. Posttransplant treatment consisted of tacrolimus, mycophenolate mofetil, prednisolone, IA, and daclizumab. RESULTS.: During pretransplant desensitization, each of the weekly immunoadsorption treatments reduced anti-HLA antibody levels by 50% to 70%, but they returned to the pretreatment level within 1 week as measured by flow cytometry. Cytotoxic antibodies remained reduced. After perioperative immunoadsorption, the donor-reactive antibodies (DRAs) were reduced to low levels. The patient underwent successful heart transplantation after 6 weeks on a waiting list. During the first week posttransplant, DRAs remained low. However, after the first week, anti-HLA DRAs reappeared and increased slightly over a 3-week period and then decreased slowly. Cytotoxic crossmatches were negative before and 3 week after transplantation. No clinical rejection was encountered. The patient was doing well 3 years after transplantation, and yearly clinical cardiac investigations were all normal. Three hyperimmunized patients have now undergone successful heart transplantation at our center using this desensitization protocol. CONCLUSIONS.: IA in combination with pretransplant immunosuppressive drug treatment temporarily reduces antibody levels. The therapeutic levels of drug treatment at the time of transplantation may be of crucial importance. The treatment protocol resulted in freedom from rejection and other clinical adverse events.
  •  
8.
  • Dellgren, Göran, 1961, et al. (författare)
  • Three decades of heart transplantation in Scandinavia: long-term follow-up
  • 2013
  • Ingår i: European Journal of Heart Failure. - : Wiley. - 1879-0844 .- 1388-9842. ; 15:3, s. 308-315
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim Heart transplantation (HTx) has become a standard treatment for patients with end-stage heart disease. The aim of this study was to report the long-term outcome after HTx in Scandinavia. Methods and results During the period, 1983-2009,2333 HTxs were performed in 2293 patients (mean age 45 +/- 16 years, range 0-70,78% mate). The main indications for HTx were non-ischaemic cardiomyopathy (50%), ischaemic cardiomyopathy (34%), valvular cardiomyopathy (3%), congenital heart disease (7%), retransplantation (2%), and miscellaneous (4%). The registry consists of pre-operative data from recipients and donors, data from pre-operative procedures, and long-term follow-up data. Mean follow-up was 7.8 +/- 6.6 years (median 6.9, interquartile range 2.5-12.3, interval 0-27) and no patients were lost to follow-up. Long-term survival for HTx patients was 85, 76, 61, 43, and 30% at 1, 5, 10, 15, and 20 years of follow-up, respectively. Ten-year survival in patients bridged with mechanical circulatory support, in children, after retransplantation, and after concomitant other organ transplantation was 56, 74, 38, and 43%, respectively. Older patients (age >55 years) had a significantly worse survival (P < 0.001). Patients transplanted more recently had a significantly better survival (P < 0.001). In a multivariate Cox regression analysis, independent predictors of long-term survival were recipient age (P < 0.001), donor age (P < 0.001), diagnosis (P = 0.001), and era of transplantation (P < 0.001). Conclusions HTx in Scandinavia proves to have a significantly better survival among patients transplanted in the last decade. HTxs from mechanical circulatory support, in children, after retransplantation, and with concomitant other organ transplantation were performed with acceptable results.
  •  
9.
  • Dias, Nuno, et al. (författare)
  • Complicated Acute Type B Dissections-An 8-years Experience of Endovascular Stent-graft Repair in a Single Centre.
  • 2006
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 31:5, s. 481-486
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To analyze the experience of a single centre using stent-grafts for treatment of complicated acute aortic type B-dissections (EVR-ABD). Design. Retrospective analysis of prospectively collected data from patients undergoing EVR-ABD between January 1997 and December 2004. Methods. EVR-ABD was performed in 31 patients (20 males, median age 74. years (IQR: 64-79)). Indications for treatment were aortic rupture (22 patients), intractable pain and hypertension (six patients), acute bowel ischemia (two patients) and transient paraplegia, lower limb and renal ischemia in one patient. Initially home-made devices (five patients) and subsequently commercially available thoracic stent-grafts were used. Results. Five patients (16%) died within 30 days of EVR-ABD. Postoperative complications occurred in 15 (48%) patients, including one paraplegia converted to paraparesis after cerebrospinal fluid drainage, five strokes, three lower limb ischemia, three myocardial infarction, two pneumonia and one colitis). Re-interventions were required in nine patients (29%). Six more deaths occurred during a median follow-up of 22 (IQR: 16-34) months, two related to the stent-graft and four due to cardiac disease. Conclusions. Stent-graft repair of complicated acute type B dissections seems to provide acceptable results and, therefore, it may be considered a valuable alternative to open surgery.
  •  
10.
  • Eriksson, Leif, et al. (författare)
  • Lung transplantation at the University of Lund 1990-1995. Analysis of the first 39 consecutive patients
  • 1998
  • Ingår i: Scandinavian Cardiovascular Journal. - : Informa UK Limited. - 1651-2006 .- 1401-7431. ; 32:1, s. 23-28
  • Tidskriftsartikel (refereegranskat)abstract
    • Between 1990 and 1995 39 patients were lung transplanted at the University Hospital in Lund. This is a retrospective review of survival and lung function in these patients. There were 17 single-lung transplants (SLT), 21 double-lung transplants (DLT) and 1 heart-lung transplant (HLT). Seven patients died during the period, giving an overall survival of 82%. One-year survival according to Kaplan-Meier survival analysis was 87%, and 2-year survival was 83%. Vital capacity and forced expiratory volume in 1 s (FEV1) 1 year after transplantation were 91% and 100% of predicted, respectively, in the DLT group and 60% and 50% in the SLT group. Bronchiolitis obliterans syndrome (BOS) developed in 11 of the 35 patients (31%) surviving more than 6 months, 2/21 in the DLT group and 8/13 in the SLT group and in the patient with HLT. The median time until detection of BOS was 11 months after the operation (range 6-18 months). Working capacity 1 year after transplantation was 60% of predicted in the DLT group and 47% of predicted in the SLT group. Ventilatory capacity was no longer function limiting. Lung transplantation today is a therapeutic option with a good medium-term survival and good functional results in selected patients with severe lung disease.
  •  
11.
  • Eyjolfsson, Atli, et al. (författare)
  • Comparison between transcranial Doppler and coulter counter for detection of lipid micro embolization from mediastinal shed blood reinfusion during cardiac surgery.
  • 2011
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 26:5, s. 519-523
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Lipid micro embolization (LME) from re-transfused shed blood has been postulated to be a potential reason for short- and long-term cognitive dysfunction after cardiac surgery. The purpose of this investigation was to evaluate if transcranial Doppler (TCD) has the capacity to detect LME. METHODS: Thirteen patients undergoing cardiopulmonary bypass surgery were investigated. Each patient's cerebral circulation was monitored with transcranial Doppler during the first two minutes after re-transfusion of shed blood and blood was simultaneously sampled and characterised by a Coulter counter. RESULTS: Strong correlation was found between embolic loads, as measured by transcranial Doppler and Coulter counter (r=0.79, P<0.005). CONCLUSIONS: This pilot study shows that non-invasive monitoring by transcranial Doppler could be a potential tool to monitor LME during cardiopulmonary bypass surgery.
  •  
12.
  • Fakhro, Mohammed, et al. (författare)
  • 25-year follow-up after lung transplantation at Lund University Hospital in Sweden : superior results obtained for patients with cystic fibrosis
  • 2016
  • Ingår i: Interactive Cardiovascular and Thoracic Surgery. - : Oxford University Press (OUP). - 1569-9285 .- 1569-9293. ; 23:1, s. 65-73
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: In Sweden, two centres perform lung transplantation for a population of about 9 million and the entire population is covered for lung transplantation by government health insurance. Lund University Hospital is one of these centres. This retrospective report reviews the 25-year experience of the Skåne University Hospital Lung Transplant Program with particular emphasis on short-term outcome and long-term survival but also between different subgroups of patients and types of transplant [single-lung transplantation (SLTx) versus double-lung transplantation (DLTx)] procedure performed.METHODS: Between January 1990 and June 2014, 278 patients underwent lung transplantation at the Skåne University Hospital Sweden. DLTx was performed in 172 patients, SLTx was performed in 97 patients and heart-lung transplantation was performed in 9 patients. In addition, 15 patients required retransplantation (7 DLTx and 8 SLTx).RESULTS: Overall 1-, 5-, 10-, 15- and 20-year survival rates were 88, 65, 49, 37 and 19% for the whole cohort. DLTx recipients showed 1-, 5-, 10- and 20-year survival rates of 90, 71, 60 and 30%, compared with SLTx recipients with 1-, 5-, 10- and 20-year survival rates of 83, 57, 34 and 6% (P < 0.05), respectively. Comparing the use of intraoperative extracorporeal membrane oxygenation, extracorporeal circulation (ECC) and no circulatory support in the aspect of survival, a significant difference in favour of intraoperative ECC was seen.CONCLUSIONS: Superior long-term survival rates were seen in recipients diagnosed with cystic fibrosis, α1-antitrypsin deficiency and pulmonary hypertension. DLTx showed better results compared with SLTx especially at 10 years post-transplant. In the present study, we present cumulative incidence rates of bronchiolitis obliterans syndrome of 15% at 5 years, 26% at 10 years and 32% at 20 years post-transplant; these figures are in line with the lowest rates presented internationally.
  •  
13.
  • Fakhro, Mohammed, et al. (författare)
  • Double lung, unlike single lung transplantation might provide a protective effect on mortality and bronchiolitis obliterans syndrome
  • 2017
  • Ingår i: Journal of Cardiothoracic Surgery. - : Springer Science and Business Media LLC. - 1749-8090. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Survival after lung transplantation (LTx) is often limited by bronchiolitis obliterans syndrome (BOS).METHOD: Survey of 278 recipients who underwent LTx. The endpoint used was BOS (BOS grade ≥ 2), death or Re-lung transplantation (Re-LTx) assessed by competing risk regression analyses.RESULTS: The incidence of BOS grade ≥ 2 among double LTx (DLTx) recipients was 16 ± 3% at 5 years, 30 ± 4% at 10 years, and 37 ± 5% at 20 years, compared to single LTx (SLTx) recipients whose corresponding incidence of BOS grade ≥ 2 was 11 ± 3%, 20 ± 4%, and 24 ± 5% at 5, 10, and 20 years, respectively (p > 0. 05). The incidence of BOS grade ≥ 2 by major indications ranked in descending order: other, PF, CF, COPD, PH and AAT1 (p < 0. 05). The mortality rate by major indication ranked in descending order: COPD, PH, AAT1, PF, Other and CF (p < 0. 05).CONCLUSION: No differences were seen in the incidence of BOS grade ≥ 2 regarding type of transplant, however, DLTx recipients showed a better chance of survival despite developing BOS compared to SLTx recipients. The highest incidence of BOS was seen among CF, PF, COPD, PH, and AAT1 recipients in descending order, however, CF and PF recipients showed a better chance of survival despite developing BOS compared to COPD, PH, and AAT1 recipients.
  •  
14.
  • Granfeldt, Hans, et al. (författare)
  • The Linkoping-Lund surgical experience with the HeartMate left ventricular assist system
  • 1995
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 59:Suppl. 1, s. 52-55
  • Tidskriftsartikel (refereegranskat)abstract
    • Four transplant candidates fulfilling the Food and Drug Administration criteria for a permanent left ventricular assist device received a pneumatic HeartMate system as a bridge to heart transplantation. All patients survived and were fully rehabilitated at the time of transplantation, which was carried out 2 to 6 months after the initial operation. There were no major complications associated with the procedures. We are impressed by the effectiveness and safety of the device.
  •  
15.
  • Ingemansson, Richard, et al. (författare)
  • Clinical transplantation of initially rejected donor lungs after reconditioning ex vivo.
  • 2009
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier BV. - 1552-6259 .- 0003-4975. ; 87:1, s. 255-260
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: A major problem in clinical lung transplantation is the shortage of donor lungs. Only about 20% of donor lungs are accepted for transplantation. A method to evaluate and recondition lungs ex vivo has been tested on donor lungs that have been rejected for transplantation. METHODS: The donor lungs were reconditioned ex vivo in an extracorporeal membrane oxygenation (ECMO) circuit with STEEN solution (Vitrolife AB, Kungsbacka, Sweden) mixed with erythrocytes. The hyperoncotic solution dehydrates edematous lung tissue. Functional evaluations were performed with deoxygenated perfusate by varying the inspired fraction of oxygen. After the reconditioning, the lungs were kept immersed at 8 degrees C in extracorporeal membrane oxygenation until transplantation was performed. RESULTS: Six of nine initially rejected donor lungs were reconditioned to acceptable function, and in six recipients, double lung transplantation was performed. Three-month survival was 100%. One patient has since died due to sepsis after 95 days, and one due to rejection after 9 months. Four recipients are alive and well without any sign of bronchiolitis obliterans syndrome 24 months after the transplantation. CONCLUSIONS: The result from the present study is promising, and we continue to transplant reconditioned lungs.
  •  
16.
  •  
17.
  • Koul, Bansi, et al. (författare)
  • A modified Ross operation to prevent pulmonary autograft dilatation.
  • 2007
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940. ; 31:1, s. 127-128
  • Tidskriftsartikel (refereegranskat)abstract
    • A modification in Ross operation is described in which the free-standing pulmonary autograft root is suspended in a Dacron prosthetic vascular jacket with a view to prevent dilatation of the neo-aortic root. In a group of 13 patients operated consecutively using this technique, there was no significant increase in the diameters of the neo-aortic root after a mean 16-month follow-up. Aortic valve function remained also satisfactory.
  •  
18.
  •  
19.
  • Koul, Bansi, et al. (författare)
  • HeartMate left ventricular assist device as bridge to heart transplantation
  • 1998
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 65:6, s. 1625-1630
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Because of the limited supply of donor hearts, prospective recipients continue to die while on the waiting list for heart transplantation. Use of long-term mechanical circulatory support devices as a bridge to transplantation may reduce this mortality. However, with the present state of technology, continued clinical evaluation of the various long-term, mechanical circulatory support devices available is mandatory. METHODS: Sixteen patients were bridged with the HeartMate left ventricular assist device (LVAD) to heart transplantation for New York Heart Association functional class IV cardiac failure. Twelve pneumatic and six electric devices were used. The mean cardiac index and the mean pulmonary vascular resistance of the patient cohort were 1.71 x min(-1) x m(-2) and 3.1 Wood units, respectively. RESULTS: The mean LVAD support time per transplanted patient was 237 days, with a cumulative LVAD support time of about 7.2 years. Bleeding was the main operative and postoperative complication. Two patients suffered from neurologic complications and there were two major incidents of device malfunction. Twelve patients (75%) now have received a transplant, 3 (19%) are awaiting a transplant, and in 1 patient (6%), the device was explanted after spontaneous left ventricular recovery. Eleven of the 12 patients who received a transplant are alive and doing well. The HeartMate LVAD gave adequate circulatory support over extended periods of time and reversed the vital organ dysfunction. Since the start of the LVAD program, only 1 patient has died on our heart transplantation waiting list, compared to nine deaths in the 2 preceding years. CONCLUSIONS: The HeartMate LVAD bridge to heart transplantation can be performed with low post-LVAD implantation and posttransplantation mortality and offers 1- and 2-year posttransplantation actuarial survival rates comparable to those for nonbridged heart transplant recipients.
  •  
20.
  •  
21.
  •  
22.
  • Koul, Bansi (författare)
  • New deairing technique: Questions and caveats Reply
  • 2011
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 142:5, s. 1285-1286
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
23.
  • Koul, Bansi, et al. (författare)
  • Pulmonary sequelae of prolonged total venoarterial bypass: evaluation with a new experimental model
  • 1991
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 51:5, s. 794-799
  • Tidskriftsartikel (refereegranskat)abstract
    • Total normothermic venoarterial bypass was established in 6 healthy pigs over a period of 18 hours. A heparin-coated closed extracorporeal system was used and no heparin was administered systemically. During the bypass period the main pulmonary artery was occluded and the heart was maintained in a beating state. All the animals maintained stable hemodynamics and normal blood gases during the entire period of bypass. In the postbypass period, the central hemodynamics continued to be stable while the arterial oxygen tension (inspired oxygen fraction = 0.21) decreased significantly (p less than or equal to 0.05). The total body oxygen uptake, on the other hand, remained unaltered. All the animals died within 4 hours after weaning off the venoarterial bypass circuit on account of pulmonary edema in 2 and cardiac arrest in 4. Death was preceded by progressive pulmonary hypertension and lactacidosis in all the animals. Histological examination of the lungs showed pulmonary parenchymal damage ranging from interstitial edema to intraalveolar hemorrhage and parenchymal necrosis involving more than 80% of the pulmonary parenchyma. A normothermic total venoarterial bypass of 18 hours duration or more produces pulmonary edema of varying severity, pulmonary hypertension, pulmonary parenchymal necrosis, and lactacidosis in healthy juvenile pigs, resulting uniformly in their death. Despite these sequelae the systemic arterial hypoxemia may only be mild to moderate.
  •  
24.
  • Koul, Bansi, et al. (författare)
  • Twenty-four-hour heparin-free veno-right ventricular ECMO: an experimental study
  • 1992
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 53:6, s. 1046-1051
  • Tidskriftsartikel (refereegranskat)abstract
    • Platelets and coagulation factors were studied during 24-hour heparin-free veno-right ventricular extracorporeal membrane oxygenation (ECMO) in 6 healthy pigs. An endpoint attached and covalently bonded heparin-coated ECMO system was used in these experiments. The veno-right ventricular ECMO supplied the total lung function of the animals, and after 24 hours, all the animals were successfully weaned from ECMO. Lung function and central hemodynamics were not affected by the procedure. Because all the animals showed a significant reduction in plasma volume, the concentration of measured coagulation variables was corrected both for plasma volume changes and for hemodilution. The platelet count and the plasma-free hemoglobin level were not significantly altered by ECMO. Similarly, the prothrombin complex, antithrombin, thrombin-antithrombin complex, factor XII, and the urinary excretion of 2,3-dinor-thromboxane B2 were not significantly altered. Fibrinogen and fibrin monomer increased significantly, whereas von Willebrand factor was significantly decreased after ECMO. In summary, 24-hour heparin-free veno-right ventricular total extracorporeal lung assistance does not affect the platelets and the coagulation system significantly in healthy juvenile pigs.
  •  
25.
  • Koul, Bansi, et al. (författare)
  • Veno-right ventricular bypass as total extracorporeal lung assistance. An experimental study
  • 1991
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - 1097-685X. ; 101:4, s. 719-723
  • Tidskriftsartikel (refereegranskat)abstract
    • Efficacy of veno-right ventricular bypass as a total extracorporeal lung assistance was studied for a period of 24 hours in six healthy pigs with a mean weight of 60 kg. A covalently bonded heparin-coated extracorporeal membrane oxygenation system and a roller pump were used for the bypass. No local or systemic heparin was administered. The bypass was established with an open chest with two 28F venous cannulas and one 24F arterial cannula. The arterial cannula was placed in the right ventricle across the tricuspid valve. With the lung function totally disabled, this extracorporeal lung assistance maintained normal systemic arterial and mixed venous blood gases during the entire 24-hour period in all the animals. No significant tricuspid insufficiency was observed, and the animals maintained normal central hemodynamics. There was no hemolysis, and the platelet counts remained essentially unaltered. Multiple foci of clot formation were observed in all the oxygenators, but no macroscopic thrombosis or embolization was seen either in the heart or in the lungs. A veno-right ventricular bypass offers total extracorporeal lung assistance in 60 kg juvenile pigs for a period of 24 hours. Tricuspid valve competence is an important prerequisite for the success of this procedure.
  •  