    • BackgroundCarbapenem-resistant Enterobacteriaceae (CRE) is an increasing problem worldwide, but particularly problematic in low- and middle-income countries (LMIC) due to limitations of resources for surveillance of CRE and infection prevention and control (IPC).MethodsA point prevalence survey (PPS) with screening for colonisation with CRE was conducted on 2233 patients admitted to neonatal, paediatric and adult care at 12 Vietnamese hospitals located in northern, central and southern Vietnam during 2017 and 2018. CRE colonisation was determined by culturing of faecal specimens on selective agar for CRE. Risk factors for CRE colonisation were evaluated. A CRE admission and discharge screening sub-study was conducted among one of the most vulnerable patient groups; infants treated at an 80-bed Neonatal ICU from March throughout June 2017 to assess CRE acquisition, hospital-acquired infection (HAI) and treatment outcome.ResultsA total of 1165 (52%) patients were colonised with CRE, most commonly Klebsiella pneumoniae (n=805), Escherichia coli (n=682) and Enterobacter spp. (n=61). Duration of hospital stay, HAI and treatment with a carbapenem were independent risk factors for CRE colonisation. The PPS showed that the prevalence of CRE colonisation increased on average 4.2 % per day and mean CRE colonisation rates increased from 13% on the day of admission to 89% at day 15 of hospital stay. At the NICU CRE colonisation increased from 32% at admission to 87% at discharge, mortality was significantly associated (OR 5•5, P < 0•01) with CRE colonisation and HAI on admission.ConclusionThese data indicate that there is an epidemic spread of CRE in Vietnamese hospitals with rapid transmission to hospitalised patients.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Mai, Tam T., et al. (författare)
  • An overview of grid-edge control with the digital transformation
  • 2021
  • Ingår i: Electrical Engineering. - : Springer Science and Business Media LLC. - 1432-0487 .- 0948-7921. ; 103:4, s. 1989-2007
  • Tidskriftsartikel (refereegranskat)abstract
    • Distribution networks are evolving to become more responsive with increasing integration of distributed energy resources (DERs) and digital transformation at the grid edges. This evolution imposes many challenges to the operation of the network, which then calls for new control and operation paradigms. Among others, a so-called grid-edge control is emerging to harmonise the coexistence of the grid control system and DER’s autonomous control. This paper provides a comprehensive overview of the grid-edge control with various control architectures, layers, and strategies. The challenges and opportunities for such an approach at the grid edge with the integration of DERs and digital transformation are summarised. The potential solutions to support the network operation by using the inherent controllability of DER and the availability of the digital transformation at the grid edges are discussed.
  •  
7.
  • Tran, Minh Quan, et al. (författare)
  • MPC-Based Coordinated Voltage Control in LV Distribution Systems: A Case Study in Chalmers Campus Network
  • 2023
  • Ingår i: Conference Proceedings - 2023 IEEE Asia Meeting on Environment and Electrical Engineering, EEE-AM 2023.
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents detailed analysis results of a model predictive control (MPC)-based coordinated voltage control demonstrated in a real low voltage network, the Chalmers campus in Sweden. First, the modeling of the MPC is presented, and the state space mode is obtained by linearization of the power flow equation around the operation point. Thus, an updated voltage vector in the grid is calculated through the sensitivity gain corresponding to reactive power deviation in the grid. Second, the developed MPC model is integrated into an Internet of Things (IoT) platform developed under the European FlexiGrid project. The state measurements in the Chalmers campus network are collected through the IoT platform as the input for the MPC model. Then, the optimal setpoints for distributed energy resources (DERs) are calculated and sent to DERs via the IoT platform. Lastly, onsite demonstration results are analyzed, showing the performance of the MPC-based voltage control in low-voltage distribution systems.
  •  
8.
  • Tran, Minh Quan, et al. (författare)
  • Self-adaptive Controllers for Renewable Energy Communities Based on Transformer Loading Estimation
  • 2022
  • Ingår i: 2022 IEEE International Conference on Environment and Electrical Engineering and 2022 IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2022.
  • Konferensbidrag (refereegranskat)abstract
    • In this paper, self-adaptive controllers for renewable energy communities based on data-driven approach are proposed to mitigate the voltage rise and transformer congestion at the community level. In the proposed approach, the transformer loading percentage is estimated by the trained data-driven model, which uses the extreme gradient boosting regression algorithm based on a measurement set acquired from critical coupling points of the communities. To avoid voltage rise issues, the droop control parameters (i.e., voltage threshold for P - V, Q - V curves) are adaptively tuned based on the solar irradiance availability and estimated transformer loading. The proposed approach has been tested in the IEEE European LV distribution network. Results showed that the control approach could effectively reduce 22.2 % of the total overloaded instances, while still keeping voltage magnitude in the operation range. This method can help DSOs manage voltage violation and congestion without further communication.
  •  