SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Moszynski M.) "

Sökning: WFRF:(Moszynski M.)

  • Resultat 1-25 av 53
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Sherratt, K., et al. (författare)
  • Predictive performance of multi-model ensemble forecasts of COVID-19 across European nations
  • 2023
  • Ingår i: eLIFE. - : eLife Sciences Publications Ltd. - 2050-084X. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • Methods: We used open-source tools to develop a public European COVID-19 Forecast Hub. We invited groups globally to contribute weekly forecasts for COVID-19 cases and deaths reported by a standardised source for 32 countries over the next 1–4 weeks. Teams submitted forecasts from March 2021 using standardised quantiles of the predictive distribution. Each week we created an ensemble forecast, where each predictive quantile was calculated as the equally-weighted average (initially the mean and then from 26th July the median) of all individual models’ predictive quantiles. We measured the performance of each model using the relative Weighted Interval Score (WIS), comparing models’ forecast accuracy relative to all other models. We retrospectively explored alternative methods for ensemble forecasts, including weighted averages based on models’ past predictive performance.Results: Over 52 weeks, we collected forecasts from 48 unique models. We evaluated 29 models’ forecast scores in comparison to the ensemble model. We found a weekly ensemble had a consistently strong performance across countries over time. Across all horizons and locations, the ensemble performed better on relative WIS than 83% of participating models’ forecasts of incident cases (with a total N=886 predictions from 23 unique models), and 91% of participating models’ forecasts of deaths (N=763 predictions from 20 models). Across a 1–4 week time horizon, ensemble performance declined with longer forecast periods when forecasting cases, but remained stable over 4 weeks for incident death forecasts. In every forecast across 32 countries, the ensemble outperformed most contributing models when forecasting either cases or deaths, frequently outperforming all of its individual component models. Among several choices of ensemble methods we found that the most influential and best choice was to use a median average of models instead of using the mean, regardless of methods of weighting component forecast models.Conclusions: Our results support the use of combining forecasts from individual models into an ensemble in order to improve predictive performance across epidemiological targets and populations during infectious disease epidemics. Our findings further suggest that median ensemble methods yield better predictive performance more than ones based on means. Our findings also highlight that forecast consumers should place more weight on incident death forecasts than incident case forecasts at forecast horizons greater than 2 weeks.
  •  
2.
  • Jaworski, G., et al. (författare)
  • The New Neutron Multiplicity Filter NEDA and Its First Physics Campaign with AGATA
  • 2019
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 50:3, s. 585-590
  • Tidskriftsartikel (refereegranskat)abstract
    • A new neutron multiplicity filter NEDA, after a decade of design, R&D and construction, was employed in its first physics campaign with the AGATA spectrometer. Properties and performance of the array are discussed.
  •  
3.
  • Valiente-Dobon, J. J., et al. (författare)
  • NEDA-NEutron Detector Array
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 927, s. 81-86
  • Tidskriftsartikel (refereegranskat)abstract
    • The NEutron Detector Array, NEDA, will form the next generation neutron detection system that has been designed to be operated in conjunction with gamma-ray arrays, such as the tracking-array AGATA, to aid nuclear spectroscopy studies. NEDA has been designed to be a versatile device, with high-detection efficiency, excellent neutron-gamma discrimination, and high rate capabilities. It will be employed in physics campaigns in order to maximise the scientific output, making use of the different stable and radioactive ion beams available in Europe. The first implementation of the neutron detector array NEDA with AGATA 1 pi was realised at GANIL. This manuscript reviews the various aspects of NEDA.
  •  
4.
  • Fahlander, Claes, et al. (författare)
  • Excited States in 103Sn: Neutron Single-particle Energies with Respect to 100Sn
  • 2001
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813 .- 1089-490X. ; 63:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Gamma-ray lines from Sn-103 have been identified for the first time using EUROBALL and ancillary detectors. The level scheme of Sn-103 has been established by means of particle-gated gamma gamma coincidences. The energy spacing between the g(7/2) and d(5/2) neutron single-particle orbitals is determined from the excited states in Sn-103.
  •  
5.
  • Gadea, A., et al. (författare)
  • Observation of Ni-54 : Cross-conjugate symmetry in f(7/2) mirror energy differences
  • 2006
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 97:15, s. 152501-
  • Tidskriftsartikel (refereegranskat)abstract
    • Gamma decays from excited states up to J(pi)=6(+) in the N=Z-2 nucleus Ni-54 have been identified for the first time. Level energies are compared with those of the isobars Co-54 and Fe-54 and of the cross-conjugate nuclei of mass A=42. The good but puzzling f(7/2) cross-conjugate symmetry in mirror and triplet energy differences is analyzed. Shell model calculations reproduce the new data but the necessary nuclear charge-dependent phenomenology is not fully explained by modern nucleon-nucleon potentials.
  •  
6.
  • Palacz, M., et al. (författare)
  • Investigations of Neutron Deficient Nuclei Close to 100Sn with EUROBALL
  • 2001
  • Ingår i: Acta Physica Polonica. Series B: Elementary Particle Physics, Nuclear Physics, Statistical Physics, Theory of Relativity, Field Theory. - 0587-4254 .- 1509-5770. ; 32, s. 999-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Excited states of nuclei in the vicinity of Sn-100 have been studied using: the EUROBALL detector array. Gamma-ray lines from Sn-103 have been identified for the first time, and a level scheme of low-lying excited states of Sn-103 has been established. New constraints on energies of single particle orbitals with respect to the Sn-100 core are obtained.
  •  
7.
  • Sohler, D, et al. (författare)
  • Maximally Aligned States in the Proton Drip Line Nucleus 106Sb
  • 2005
  • Ingår i: Nuclear Physics, Section A. - : Elsevier BV. - 0375-9474 .- 1873-1554. ; 753:3-4, s. 251-262
  • Tidskriftsartikel (refereegranskat)abstract
    • High-spin states in Sb-106 have been investigated in the Fe-54(Ni-58, 1α 1p1n) reaction by in-beam γ-spectroscopic methods using the EUROBALL detector array equipped with charged particle and neutron detectors. On the basis of measured γγ-coincidence relations, angular distributions, and linear polarization ratios a significantly extended level scheme has been constructed up to spin and parity I-π = (19(-)) and E-x ∼ 6.5 MeV. The experimental results are interpreted within the framework of the gdsh shell model using a realistic effective nucleon-nucleon interaction. Candidates for states with fully aligned angular momenta in the π(d(5/2), g(7/2))(1) v (d(5/2), g(7/2))(5) valence space are identified at 4338 and 5203 keV, as well as in the π(d(5/2), g(7/2))(1) V(d(5/2), g(7/2))(4)h(11/2)(1) space at 6087, 6573 and 6783 keV.
  •  
8.
  • Egea Canet, F. J., et al. (författare)
  • A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1056-1062
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
  •  
9.
  • Egea Canet, F. J., et al. (författare)
  • Digital Front-End Electronics for the Neutron Detector NEDA
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1063-1069
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016.
  •  
10.
  • Sohler, D, et al. (författare)
  • Neutron Excitations Across the N=50 Shell Gap in 102In
  • 2002
  • Ingår i: Nuclear Physics, Section A. - : Elsevier. - 0375-9474 .- 1873-1554. ; 708:3-4, s. 181-189
  • Tidskriftsartikel (refereegranskat)abstract
    • The structure of In-102 has been investigated by in-beam gamma-spectroscopic methods. Knowledge on the excited states of this nucleus has significantly been extended. Three cascades of transitions were observed to exceed the spin-energy domain spanned by the pig(9/2)(-1)v(d(5/2),g(7/2))(3) configurations. The new high spin states at similar to 4 MeV excitation energy could be assigned to the pig(9/2)(-1)v(d(5/2), g(7/2))(2)h (11/2) configuration, while at least those at 4.733, 5.192 and 5.853 MeV most likely arise from the vg(9/2) --> vd(5/2), g(7/2) one-particle-one-hole excitation across the N = 50 shell closure.
  •  
11.
  • Palacz, M, et al. (författare)
  • Highly efficient charged particle veto detector CUP
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 550:1-2, s. 414-424
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel, highly efficient, plastic scintillator detector has been constructed. The primary application of the detector is to act as a veto device in heavy-ion-induced fusion-evaporation reactions, in which the structure of proton-rich nuclides is investigated by gamma-ray spectroscopy methods. The detector rejects events in which light charged particles, like protons and alpha particles, are emitted in the evaporation process, facilitating selection of reaction channels associated with emission of only neutrons. The detector was used in a EUROBALL experiment, with achieved efficiencies of 80% and 63% for protons and alpha particles, respectively. The design of the detector, its performance and limitations are discussed.
  •  
12.
  • Pausch, G., et al. (författare)
  • RoSiB - a 4 pi silicon ball for charged-particle detection in EUROBALL
  • 2000
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 443:03-feb, s. 304-318
  • Tidskriftsartikel (refereegranskat)abstract
    • A 4 pi silicon bail for detection and identification of light charged particles in large multidetector gamma-arrays as EUROBALL is presented. The design is based on a N = 42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive material for gamma-rays is minimized to the detector thickness of 300 or 500 mu m and a 0.63 mm ceramic backing. The geometrical coverage is designed for about 90% of 4 pi. A pulse shape discrimination method with totally depleted detectors working in the reverse mount allows identifying protons and alpha-particles above an energy threshold of about 2 MeV. The performances of the ball were rested at the tandem - booster accelerator combination of the MPI Heidelberg in two experiments using the high-recoil reaction of 228 MeV Ni-58 + Ti-46 and the low-recoil reaction of 95 MeV O-16 + Ni-58. The two-dimensional spectra of zero-crossing (ZC) versus energy confirmed an excellent discrimination of protons and alpha-particles in all the detectors at different angles. The energy spectra of protons and alpha-particles measured in the experiments are presented. too. The gamma-spectra measured in coincidence with various combinations of emitted particles showed a high selectivity of the ball. The reduced total efficiency for protons of 59% and 55% and alpha-particles of 44% and 32% measured in a nuclear spectroscopy application is analyzed in a Monte-Carlo simulation (GEANT). It is due to a combined influence of a thick target needed to stop the recoiling residual nuclei and thick absorbers needed to protect the Si-detectors from scattered beam. The results along with the GEANT extrapolation to optimum experimental conditions confirm that RoSiB is a highly efficient and selective device for identification of rare reaction channels with heavy ions.
  •  
13.
  • Perot, B., et al. (författare)
  • Measurement of 14 MeV neutron-induced prompt gamma-ray spectra from 15 elements found in cargo containers
  • 2008
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 66:4, s. 421-434
  • Tidskriftsartikel (refereegranskat)abstract
    • Within the EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) project, the gamma-ray spectra produced in a series of materials by 14-MeV tagged-neutron beams have been collected in the inspection portal equipped with large volume Nal(Tl) detectors, in order to build a database of signatures for various elements: C, N, O, Na, Al, Si, Cl, K, Ca, Cr, Fe, Ni, Cu, Zn, Pb. The measured spectra have been compared with prediction from Monte Carlo simulations to verify the consistency of the relevant nuclear data inputs. This library of measured 14-MeV neutron-induced gamma-ray spectra is currently used in a data processing algorithm to unfold the energy spectra of the transported goods into elementary contributions, thus allowing material identification.
  •  
14.
  • Perot, B., et al. (författare)
  • The EURITRACK project : Development of a tagged neutron inspection system for cargo containers
  • 2006
  • Ingår i: Proc SPIE Int Soc Opt Eng. - : SPIE. - 0819462691 - 9780819462695
  • Konferensbidrag (refereegranskat)abstract
    • The EURopean Illicit TRAfficing Countermeasures Kit project is part of the 6th European Union Framework Program, and aims at developing a neutron inspection system for detecting threat materials (explosives, drugs, etc.) in cargo containers. Neutron interaction in the container produces specific gamma-rays used to determine the chemical composition of the inspected material. An associated particle sealed tube neutron generator is developed to allow precise location of the interaction point by direction and time-of-flight measurements of the neutrons tagged by alpha-particles. The EURITRACK project consists in developing: a transportable deuterium-tritium neutron generator including a position sensitive alpha detector (8×8 matrix of YAP:Ce crystals coupled to a multi-anode photomultiplier), fast neutron and gamma-ray detectors, front-end electronics to perform coincidence and spectroscopic measurements, and an integrated software which manages neutron generator and detectors positioning, data acquisition and analysis. Hardware components have been developed and tested by the consortium partners. Current status of this work and provisional performances of the system assessed by Monte Carlo calculations are presented.
  •  
15.
  • Skeppstedt, O, et al. (författare)
  • The EUROBALL neutron wall - design and performance tests of neutron detectors
  • 1999
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : ELSEVIER SCIENCE BV. ; 421:3, s. 531-541
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The mechanical design of the EUROBALL neutron wall and neutron detectors, and their performance measured with a Cm-246,Cm-248 fission source are described. The array consists of 15 pseudohexaconical detector units subdivided into three, 149 mm high, herme
  •  
16.
  • Viesti, G., et al. (författare)
  • Scanning cargo containers with tagged neutrons
  • 2007
  • Ingår i: 7th Latin American Symposium on Nuclear Physics and Applications. - : American Institute of Physics (AIP). - 0735404615 - 9780735404618 ; , s. 57-62
  • Konferensbidrag (refereegranskat)abstract
    • A new Tagged Neutron Inspection System (TNIS) able to detect illicit materials such as explosives and narcotics in cargo containers has been developed within the EURopean Illicit TRAfficing Countermeasures Kit (EURITRACK) project. After the R&D phase, the inspection portal has been installed and commissioned at the Rijeka seaport in Croatia, where it has been operated in connection with the existing X-ray scanner for a first two-month demonstration campaign. Results obtained are presented and discussed in this paper.
  •  
17.
  • Balcerzyk, M., et al. (författare)
  • Energy resolution and light yield non-proportionality of ZnSe : Te scintillator studied by large area avalanche photodiodes and photomultipliers
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 482:3, s. 720-727
  • Tidskriftsartikel (refereegranskat)abstract
    • The ZnSe: Te scintillator has been studied by means of a photomultiplier with an extended bialkali photocathode, a large area avalanche photodiode (LAAPD) and a PIN photodiode. The light output was determined to be 28 300+/-1700 photons/MeV. Results indicate good proportionality for light output versus gamma-ray energy. Measurements of the 662 keV gamma-ray energy spectrum recorded using a LAAPD resulted in an energy resolution of 5.4+/-0.3%. Based on these results, an intrinsic energy resolution of 3.3+/-0.7% has been calculated.
  •  
18.
  • Moszynski, M., et al. (författare)
  • Energy resolution and non-proportionality of the light yield of pure CsI at liquid nitrogen temperatures
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 537:02-jan, s. 357-362
  • Tidskriftsartikel (refereegranskat)abstract
    • The energy resolution and non-proportionality of the light yield versus gamma-ray energy of pure CsI scintillators directly coupled to Large Area Avalanche Photodiodes (LAAPDs) and cooled down to the liquid nitrogen temperatures have been studied. A very high light output above 100 000 ph/MeV was measured. One of the samples showed nearly proportional light yield response versus energy of gamma-rays yielding energy resolution of 4.3-0.2% for 662 keV gamma-rays from a (CS)-C-137 source. The intrinsic resolution of the crystals versus energy of gamma-rays has been estimated by measurements of the number of primary electron-hole pairs generated in LAAPD by scintillation light. Inspection of the gamma-ray-induced emission spectra of tested samples allows discussing different shapes of non-proportionality curves observed with various samples of CsI.
  •  
19.
  • Moszynski, M., et al. (författare)
  • Study of pure NaI at room and liquid nitrogen temperatures
  • 2003
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 50:4, s. 767-773
  • Tidskriftsartikel (refereegranskat)abstract
    • Three pure NaI crystals grown in different batches by Scionix (The Netherlands) were studied at room and liquid nitrogen temperatures. The room temperature studies performed with photomultiplier readout covered measurements of emission spectra, photoelectrons yield and energy resolution. Moreover, the scintillation light poises were measured by single photon method. Two crystals showed the photoelectron yield of about 1000 phe/MeV measured at room temperature with an XP2020Q photomultiplier. The energy resolution of the 662 keV photopeak was measured to, be about 16% and was limited mainly by a low number of photoelectrons and a large nonproportionality of the light yield. The fast light pulse had the main decay time components of 1 and 5 ns. The high initial photon intensity of the tested NaI crystals revealed a good timing. resolution of about 140 ps obtained for Co-60 gamma-rays. At. liquid nitrogen temperatures the measurements of light yield and energy resolution were performed using An Advanced Photonix, Inc. avalanche photodiode readout A high light output above 80 000 ph/MeV was measured for the best of the tested crystals. The energy resolutions of the 662 kAV photopeak of the three crystals differ a lot, varying from an excellent value of 3.8% to 6.2%. This suggests that the measured, pies energy resolutions depend on the purity of the scintillator samples reflected in the emission spectral The studies that were performed demonstrate the attractive properties of pure NaI at both room and LN2 temperature.
  •  
20.
  • Palacz, M., et al. (författare)
  • N=50 Core Excited States Studied in the 96Pd Nucleus
  • 2012
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813 .- 1089-490X. ; 86:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The four-proton hole Pd-96 neighbor of the doubly-magic Sn-100 nucleus was studied in-beam, using a fusion-evaporation reaction of a Ni-58 beam on a Sc-45 target. States of Pd-96 were established up to an excitation energy of 9707 keV. A core-excited odd-parity isomer with T-1/2 = 37.7(1.1) ns was identified. Shell model calculations were performed in four different model spaces. Even-parity states of Pd-96 are very well reproduced in large-scale shell model (LSSM) calculations in which excitations are allowed of up to five g(9/2) protons and neutrons across the N = Z = 50 gap, to the g(7/2), d(5/2), d(3/2), and s(1/2) orbitals. The odd-parity isomer can be only qualitatively interpreted though, employing calculation in the full fpg shell model space, with just one particle-hole core excitation.
  •  
21.
  • Palacz, M., et al. (författare)
  • Odd-Parity Sn-100 Core Excitations
  • 2013
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 44:3, s. 491-500
  • Tidskriftsartikel (refereegranskat)abstract
    • Odd-parity core excited states have been identified in two close neighbors of Sn-100: Pd-96 and Ag-97. This was done in an fusion-evaporation experiment, using a Ni-58 beam on a Sc-45 target. Even-parity core excited states in these nuclei are very well reproduced in large scale (LSSM) calculations in which particle-hole excitations are allowed with up to five g(9/2) protons and neutrons across the N = Z = 50 gap, to the g(7/2), d(5/2), d(3/2), and s(1/2) orbitals. The odd-parity states can only be qualitatively interpreted though, employing calculations in the full fpg shell model space, but with just one particle-hole core excitation allowed. A more complete model including odd-parity orbitals is need for the description of core excited states in the region of Sn-100. 
  •  
22.
  • Pausch, G, et al. (författare)
  • RoSiB - a 4 pi silicon ball for charged-particle detection in EUROBALL
  • 2000
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : ELSEVIER SCIENCE BV, AMSTERDAM. - 0168-9002. ; 443:2-3, s. 304-318
  • Tidskriftsartikel (refereegranskat)abstract
    • A 4 pi silicon bail for detection and identification of light charged particles in large multidetector gamma-arrays as EUROBALL is presented. The design is based on a N = 42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive
  •  
23.
  • Borcan, C, et al. (författare)
  • First identification of excited states in the N = Z nucleus Br-70
  • 1999
  • Ingår i: EUROPEAN PHYSICAL JOURNAL A. - : SPRINGER VERLAG. ; 5:3, s. 243-246
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Excited states in the T-z = 0 nucleus Br-70 have been investigated using the reaction Ni-58(O-16,1p3n). gamma rays were detected with one EUROBALL CLUSTER detector and three single HPGe detectors. Charged particles and neutrons were registered with the Ro
  •  
24.
  •  
25.
  • Kapusta, M., et al. (författare)
  • Comparison of the scintillation properties of LSO : Ce manufactured by different laboratories and of LGSO : Ce
  • 2000
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 47:4, s. 1341-1345
  • Tidskriftsartikel (refereegranskat)abstract
    • We measured photoelectron yield, light output, decay times of the light pulses, cerium concentration, energy resolution and time resolution of LSO:Ce manufactured by different laboratories and LGSO:Ce. The LSO samples show excellent scintillation properties: high light output, close to 30,000 ph/MeV and good energy resolution of 7.3% FWHM for Cs-137 gamma-source full energy peak. Time resolution measured in geometry fulfilling the PET scanners requirements is equal to 450 ps. We also present results fi om the measurements with LGSO:Ce by Hitachi Chemical Co., which is of similar chemical composition to LSO. LGSO, at present stage of development, shows about 20% lower light output than LSO and energy resolution of 12.4% FWHM for 662 keV gamma-rays. LSO crystals used in our studies posses similar in scintillation properties, although we suppose that the details of the productions method are different due to the differences in Ce concentration. LGSO is a new and very promising scintillator due to lower background radiation in comparison to LSO, but it features worse energy resolution and smaller number of photoelectrons.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 53

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy