SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Muders Dirk) "

Sökning: WFRF:(Muders Dirk)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Akiyama, Kazunori, et al. (författare)
  • First Sagittarius A* Event Horizon Telescope Results. II. EHT and Multiwavelength Observations, Data Processing, and Calibration
  • 2022
  • Ingår i: Astrophysical Journal Letters. - : American Astronomical Society. - 2041-8213 .- 2041-8205. ; 930:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present Event Horizon Telescope (EHT) 1.3 mm measurements of the radio source located at the position of the supermassive black hole Sagittarius A* (Sgr A*), collected during the 2017 April 5-11 campaign. The observations were carried out with eight facilities at six locations across the globe. Novel calibration methods are employed to account for Sgr A*'s flux variability. The majority of the 1.3 mm emission arises from horizon scales, where intrinsic structural source variability is detected on timescales of minutes to hours. The effects of interstellar scattering on the image and its variability are found to be subdominant to intrinsic source structure. The calibrated visibility amplitudes, particularly the locations of the visibility minima, are broadly consistent with a blurred ring with a diameter of similar to 50 mu as, as determined in later works in this series. Contemporaneous multiwavelength monitoring of Sgr A* was performed at 22, 43, and 86 GHz and at near-infrared and X-ray wavelengths. Several X-ray flares from Sgr A* are detected by Chandra, one at low significance jointly with Swift on 2017 April 7 and the other at higher significance jointly with NuSTAR on 2017 April 11. The brighter April 11 flare is not observed simultaneously by the EHT but is followed by a significant increase in millimeter flux variability immediately after the X-ray outburst, indicating a likely connection in the emission physics near the event horizon. We compare Sgr A*'s broadband flux during the EHT campaign to its historical spectral energy distribution and find that both the quiescent emission and flare emission are consistent with its long-term behavior.
  •  
2.
  • Goddi, Ciriaco, et al. (författare)
  • Polarimetric Properties of Event Horizon Telescope Targets from ALMA
  • 2021
  • Ingår i: Astrophysical Journal Letters. - : American Astronomical Society. - 2041-8213 .- 2041-8205. ; 910:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the results from a full polarization study carried out with the Atacama Large Millimeter/submillimeter Array (ALMA) during the first Very Long Baseline Interferometry (VLBI) campaign, which was conducted in 2017 April in the lambda 3 mm and lambda 1.3 mm bands, in concert with the Global mm-VLBI Array (GMVA) and the Event Horizon Telescope (EHT), respectively. We determine the polarization and Faraday properties of all VLBI targets, including Sgr A*, M87, and a dozen radio-loud active galactic nuclei (AGNs), in the two bands at several epochs in a time window of 10 days. We detect high linear polarization fractions (2%-15%) and large rotation measures (RM > 10(3.3)-10(5.5) rad m(-2)), confirming the trends of previous AGN studies at millimeter wavelengths. We find that blazars are more strongly polarized than other AGNs in the sample, while exhibiting (on average) order-of-magnitude lower RM values, consistent with the AGN viewing angle unification scheme. For Sgr A* we report a mean RM of (-4.2 0.3) x 10(5) rad m(-2) at 1.3 mm, consistent with measurements over the past decade and, for the first time, an RM of (-2.1 0.1) x 10(5) rad m(-2) at 3 mm, suggesting that about half of the Faraday rotation at 1.3 mm may occur between the 3 mm photosphere and the 1.3 mm source. We also report the first unambiguous measurement of RM toward the M87 nucleus at millimeter wavelengths, which undergoes significant changes in magnitude and sign reversals on a one year timescale, spanning the range from -1.2 to 0.3 x 10(5) rad m(-2) at 3 mm and -4.1 to 1.5 x 10(5) rad m(-2) at 1.3 mm. Given this time variability, we argue that, unlike the case of Sgr A*, the RM in M87 does not provide an accurate estimate of the mass accretion rate onto the black hole. We put forward a two-component model, comprised of a variable compact region and a static extended region, that can simultaneously explain the polarimetric properties observed by both the EHT (on horizon scales) and ALMA (which observes the combined emission from both components). These measurements provide critical constraints for the calibration, analysis, and interpretation of simultaneously obtained VLBI data with the EHT and GMVA.
  •  
3.
  • Varelmann, Dirk, et al. (författare)
  • Cardiorespiratory effects of spontaneous breathing in two different models of experimental lung injury : a randomized controlled trial
  • 2008
  • Ingår i: Critical Care. - : Springer Science and Business Media LLC. - 1364-8535 .- 1466-609X. ; 12:6, s. R135-
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Acute lung injury (ALI) can result from various insults to the pulmonary tissue. Experimental and clinical data suggest that spontaneous breathing (SB) during pressure-controlled ventilation (PCV) in ALI results in better lung aeration and improved oxygenation. Our objective was to evaluate whether the addition of SB has different effects in two different models of ALI. METHODS: Forty-four pigs were randomly assigned to ALI resulting either from hydrochloric acid aspiration (HCl-ALI) or from increased intra-abdominal pressure plus intravenous oleic acid injections (OA-ALI) and were ventilated in PCV mode either with SB (PCV + SB) or without SB (PCV - SB). Cardiorespiratory variables were measured at baseline after induction of ALI and after 4 hours of treatment (PCV + SB or PCV - SB). Finally, density distributions and end-expiratory lung volume (EELV) were assessed by thoracic spiral computed tomography. RESULTS: PCV + SB improved arterial partial pressure of oxygen/inspiratory fraction of oxygen (PaO2/FiO2) by a reduction in intrapulmonary shunt fraction in HCl-ALI from 27% +/- 6% to 23% +/- 13% and in OA-ALI from 33% +/- 19% to 26% +/- 18%, whereas during PCV - SB PaO2/FiO2 deteriorated and shunt fraction increased in the HCl group from 28% +/- 8% to 37% +/- 17% and in the OA group from 32% +/- 12% to 47% +/- 17% (P < 0.05 for interaction time and treatment, but not ALI type). PCV + SB also resulted in higher EELV (HCl-ALI: 606 +/- 171 mL, OA-ALI: 439 +/- 90 mL) as compared with PCV - SB (HCl-ALI: 372 +/- 130 mL, OA-ALI: 192 +/- 51 mL, with P < 0.05 for interaction of time, treatment, and ALI type). CONCLUSIONS: SB improves oxygenation, reduces shunt fraction, and increases EELV in both models of ALI.
  •  
4.
  • Wrigge, Hermann, et al. (författare)
  • Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury
  • 2008
  • Ingår i: Critical Care Medicine. - 0090-3493 .- 1530-0293. ; 36:3, s. 903-909
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To determine the validity of functional electric impedance tomography to monitor regional ventilation distribution in experimental acute lung injury, and to develop a simple electric impedance tomography index detecting alveolar recruitment. DESIGN: Randomized prospective experimental study. SETTING: Academic research laboratory. SUBJECTS: Sixteen anesthetized, tracheotomized, and mechanically ventilated pigs. INTERVENTIONS: Acute lung injury was induced either by acid aspiration (direct acute lung injury) or by abdominal hypertension plus oleic acid injection (indirect acute lung injury) in ten pigs. Six pigs with normal lungs were studied as a control group and with endotracheal suction-related atelectasis. After 4 hrs of mechanical ventilation, a slow inflation was performed. MEASUREMENTS AND MAIN RESULTS: During slow inflation, simultaneous measurements of regional ventilation by electric impedance tomography and dynamic computed tomography were highly correlated in quadrants of a transversal thoracic plane (r2 = .63-.88, p < .0001, bias <5%) in both direct and indirect acute lung injury. Variability between methods was lower in direct than indirect acute lung injury (11 +/- 2% vs. 18 +/- 3%, respectively, p < .05). Electric impedance tomography indexes to detect alveolar recruitment were determined by mathematical curve analysis of regional impedance time curves. Empirical tests of different methods revealed that regional ventilation delay, that is, time delay of regional impedance time curve to reach a threshold, correlated well with recruited volume as measured by CT (r2 = .63). Correlation coefficients in subgroups were r2 = .71 and r2 = .48 in pigs with normal lungs with and without closed suction related atelectasis and r2 = .79 in pigs subject to indirect acute lung injury, respectively, whereas no significant correlation was found in pigs undergoing direct acute lung injury. CONCLUSIONS: Electric impedance tomography allows assessment of regional ventilation distribution and recruitment in experimental models of direct and indirect acute lung injury as well as normal lungs. Except for pigs with direct acute lung injury, regional ventilation delay determined during a slow inflation from impedance time curves appears to be a simple index for clinical monitoring of alveolar recruitment.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy