SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Piattelli P.) "

Search: WFRF:(Piattelli P.)

  • Result 1-19 of 19
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Adrian-Martinez, S., et al. (author)
  • A first search for coincident gravitational waves and high energy neutrinos using LIGO, Virgo and ANTARES data from 2007
  • 2013
  • In: Journal of Cosmology and Astroparticle Physics. - : IOP Publishing. - 1475-7516. ; :6
  • Journal article (peer-reviewed)abstract
    • We present the results of the first search for gravitational wave bursts associated with high energy neutrinos. Together, these messengers could reveal new, hidden sources that are not observed by conventional photon astronomy, particularly at high energy. Our search uses neutrinos detected by the underwater neutrino telescope ANTARES in its 5 line configuration during the period January - September 2007, which coincided with the fifth and first science runs of LIGO and Virgo, respectively. The LIGO-Virgo data were analysed for candidate gravitational-wave signals coincident in time and direction with the neutrino events. No significant coincident events were observed. We place limits on the density of joint high energy neutrino - gravitational wave emission events in the local universe, and compare them with densities of merger and core-collapse events.
  •  
2.
  • Petroff, E., et al. (author)
  • A polarized fast radio burst at low Galactic latitude
  • 2017
  • In: Monthly notices of the Royal Astronomical Society. - : Oxford Academic. - 0035-8711 .- 1365-2966. ; 469:4, s. 4465-4482
  • Journal article (peer-reviewed)abstract
    • We report on the discovery of a new fast radio burst (FRB), FRB 150215, with the Parkes radio telescope on 2015 February 15. The burst was detected in real time with a dispersion measure (DM) of 1105.6 +/- 0.8 pc cm(-3), a pulse duration of 2.8(-0.5)(+1.2) ms, and a measured peak flux density assuming that the burst was at beam centre of 0.7(-0.1)(+0.2) Jy. The FRB originated at a Galactic longitude and latitude of 24.66 degrees, 5.28 degrees and 25 degrees away from the Galactic Center. The burst was found to be 43 +/- 5 per cent linearly polarized with a rotation measure (RM) in the range -9 < RM < 12 rad m(-2) (95 per cent confidence level), consistent with zero. The burst was followed up with 11 telescopes to search for radio, optical, X-ray, gamma-ray and neutrino emission. Neither transient nor variable emission was found to be associated with the burst and no repeat pulses have been observed in 17.25 h of observing. The sightline to the burst is close to the Galactic plane and the observed physical properties of FRB 150215 demonstrate the existence of sight lines of anomalously low RM for a given electron column density. The Galactic RM foreground may approach a null value due to magnetic field reversals along the line of sight, a decreased total electron column density from the Milky Way, or some combination of these effects. A lower Galactic DM contribution might explain why this burst was detectable whereas previous searches at low latitude have had lower detection rates than those out of the plane.
  •  
3.
  • Ageron, M., et al. (author)
  • ANTARES : The first undersea neutrino telescope
  • 2011
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 656:1, s. 11-38
  • Journal article (peer-reviewed)abstract
    • The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given. (C) 2011 Elsevier B.V. All rights reserved.
  •  
4.
  • Aguilar, J A, et al. (author)
  • Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
  • 2005
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 555:1-2, s. 132-141
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES. (c) 2005 Elsevier B.V. All rights reserved.
  •  
5.
  • Ageron, M., et al. (author)
  • Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 581:3, s. 695-708
  • Journal article (peer-reviewed)abstract
    • full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented. (c) 2007 Elsevier B.V. All rights reserved.
  •  
6.
  • Ageron, M., et al. (author)
  • The ANTARES optical beacon system
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Journal article (peer-reviewed)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
7.
  • Aguilar, J. A., et al. (author)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • In: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Journal article (peer-reviewed)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
8.
  • Aguilar, J. A., et al. (author)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
9.
  • Ageron, M., et al. (author)
  • Performance of the first ANTARES detector line
  • 2009
  • In: Astroparticle physics. - : Elsevier BV. - 0927-6505 .- 1873-2852. ; 31:4, s. 277-283
  • Journal article (peer-reviewed)abstract
    • In this paper we report on the data recorded with the first Antares detector line. The line was deployed on the 14th of February 2006 and was connected to the readout 2 weeks later. Environmental data for one and a half years of running are shown. Measurements of atmospheric muons from data taken from selected runs during the first 6 months of operation are presented. Performance figures in terms of time residuals and angular resolution are given. Finally the angular distribution of atmospheric muons is presented and from this the depth profile of the muon intensity is derived. (C) 2009 Elsevier B.V. All rights reserved.
  •  
10.
  • Checchi, V., et al. (author)
  • Wide diameter immediate post-extractive implants vs delayed placement of normal-diameter implants in preserved sockets in the molar region: 1-year postloading outcome of a randomised controlled trial
  • 2017
  • In: European Journal of Oral Implantology. - 1756-2406. ; 10:3, s. 263-278
  • Journal article (peer-reviewed)abstract
    • Purpose: To compare the effectiveness of 6.0 to 8.0 mm-wide diameter implants, placed immediately after tooth extraction, with conventional 4.0 or 5.0 mm diameter implants placed in a preserved socket after a 4-month period of healing in the molar region. Materials and Methods: Just after extraction of one or two molar teeth, and with no vertical loss of the buccal bone in relation to the palatal wall, 100 patients requiring immediate post-extractive implants were randomly allocated to immediate placement of one or two 6.0 to 8.0 mm-wide diameter implants (immediate group; 50 patients) or for socket preservation using a porcine bone substitute covered by a resorbable collagen barrier (delayed group; 50 patients), according to a parallel group design in one centre. Bone-to-implant gaps were filled with autogenous bone retrieved with a trephine drill used to prepare the implant sites for the immediate wide diameter post-extractive implants. Four months after socket preservation, one to two 4.0 or 5.0 mm-wide delayed implants were placed. Implants were loaded 4 months after placement with fixed provisional restorations in acrylic, and replaced after 4 months by fixed, definitive, metal-ceramic restorations. Patients were followed to 1 year after loading. Outcome measures were: implant failures, complications, aesthetics assessed using the pink esthetic score (PES), peri-implant marginal bone level changes, patient satisfaction, number of appointments and surgical interventions recorded, when possible, by blinded assessors. Results: Three patients dropped out 1 year after loading from the immediate group vs six from the delayed group. Five implants out of 47 failed in the immediate group (10.6%) vs two out 44 (4.6%) in the delayed group, the difference being not statistically significant (difference in proportion = 6.0%, 95% CI: -8.8% to 20.8%, P = 0.436). In the immediate group 10 patients were affected by 10 complications, while in the delayed group four patients were affected by four complications. The difference was not statistically significant (difference in proportion = 12%, 95% CI: -2% to 26%, P = 0.084). At delivery of the definitive prostheses, 4 months after loading, the mean total PES score was 9.65 ± 1.62 and 10.44 ± 1.47 in the immediate and delayed groups, respectively. At 1 year after loading, the mean total PES score was 9.71 ± 2.71 and 10.86 ± 1.37 in the immediate and delayed groups, respectively. The Total PES score was statistically significantly better at delayed implants both at 4 months (mean difference = 0.79; 95% CI: 0.05 to 1.53; P = 0.03) and at 1 year (mean difference = 1.15; 95% CI: 0.13 to 2.17; P = 0.02). Marginal bone levels at implant insertion (after bone grafting) were 0.04 mm for immediate and 0.11 mm for delayed implants, which was statistically significantly different (mean difference = 0.07; 95% CI: 0.02 to 0.12; P < 0.0001). One year after loading, patients in the immediate group lost on average 1.06 mm and those from the delayed group 0.63 mm, the difference being statistically significant (mean difference = 0.43 mm; 95% CI: 0.15 to 0.61; P < 0.0001). All patients were fully or partially satisfied both for function and aesthetics, and would undergo the same procedure again both at 4 months and 1 year after loading. Patients from the immediate group required on average 7.48 ± 1.45 visits to the clinician and 2.14 ± 0.49 surgical interventions and to have their definitive prostheses delivered vs 10.30 ± 0.99 visits and 3.08 ± 0.40 surgical interventions for the delayed group, the difference being statistically significant (P < 0.001 for visits, and P < 0.001 for surgical interventions). Conclusions: Preliminary 1 year follow-up data suggest that immediate placement of 6.0 to 8.0 mm wide diameter implants in molar extraction sockets yielded inferior aesthetic outcomes than ridge preservation and delayed placement of conventional 4.0 to 5.0 mm diameter implants. Conflict of interest statement: This trial was partially funded by the manufacturer of the implants evaluated in his investigation (MegaGen Implant Co, Gyeongbuk, South Korea). However, data belonged to the authors and in no way did the manufacturer interfere with the conduct of the trial or the publication of its results. © Quintessenz.
  •  
11.
  • Delgado-Ruiz, R. A., et al. (author)
  • Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs
  • 2014
  • In: Vojnosanitetski Pregled. - : National Library of Serbia. - 0042-8450. ; 71:5, s. 451-461
  • Journal article (peer-reviewed)abstract
    • Background/Aim. The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of pen-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Methods. Implant surface characterization was performed using optical interferometric profilometry and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length) were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium), the group A (sandblasted zirconia), the group B (sandblasted zirconia plus microgrooved neck) and the group C (sandblasted zirconia plus all microgrooved). All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon microscope (SEM) analysis of the bone-implant interfaces of each group was performed. Results. Insertion torque values were higher in the group C and control implants (p < 0.05). Periotest values increased in all the periods in proportion to the extent of microgrooving as follows: the group C > the control > the group B > the group A (p < 0.05). Radiographic measurements showed minimal crestal bone loss at 3 months for microgrooved zirconia implants (groups C and B) and control implants compared with the group A implants (p < 0.05). The removal torque values increased with time for all the groups as follows: the group C > the control > the group B > the group A (p < 0.05). SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. Conclusion. The addition of microgrooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.
  •  
12.
  • Esposito, Marco, 1965, et al. (author)
  • Posterior atrophic jaws rehabilitated with prostheses supported by 5 x 5 mm implants with a nanostructured calcium-incorporated titanium surface or by longer implants in augmented bone. Five-year results from a randomised controlled trial
  • 2019
  • In: European Journal of Oral Implantology. - 1756-2406. ; 12:1, s. 39-54
  • Journal article (peer-reviewed)abstract
    • Purpose: To evaluate whether 5 x 5 mm dental implants with a novel nanostructured calcium-incorporated titanium surface could be an alternative to implants at least 10-mm long placed in bone augmented with bone substitutes in posterior atrophic jaws. Materials and methods: Forty patients with atrophic posterior (premolar and molar areas) mandibles having 5- to 7-mm bone height above the mandibular canal, and 40 patients with atrophic maxillae having 4- to 6-mm bone height below the maxillary sinus, were randomised according to a parallel-group design to receive one to three 5-mm implants or one to three at least 10-mm long implants in augmented bone at two centres. All implants had a diameter of 5 mm. Mandibles were vertically augmented with interpositional bovine bone blocks covered with resorbable barriers. Implants were placed after 4 months. Maxillary sinuses were augmented with particulated porcine bone via a lateral window covered with resorbable barriers and implants were placed simultaneously. All implants were submerged and loaded after 4 months with provisional prostheses. Four months later, definitive screw-retained or provisionally cemented metal-ceramic or zirconia prostheses were delivered. Patients were followed to 5 years post-loading and the outcome measures were: prosthesis and implant failures, any complication and pen-implant marginal bone level changes. Results: Sixteen patients dropped out before the 5-year evaluation (four short mandibles, three short maxillae, six augmented mandibles and three augmented maxillae). In mandibles, two grafted patients were not prosthetically rehabilitated because of multiple complications, and three implants failed in the same patient (one was a replacement implant) versus one patient who lost his short implant and crown 2 years after loading. In maxillae one short implant failed with its provisional crown 3 months post-loading. There were no statistically significant differences in prostheses (difference in proportion = -0.003; 95% CI: -0.14 to 0.13; P= 1.000) and implant failures (difference in proportion = -0.03; 95% CI: -0.17 to 0.09; P = 0.609) up to 5 years after loading. Significantly more complications occurred at mandibular grafted sites: 17 augmented patients were affected by complications versus nine patients treated with short implants in mandibles (difference in proportion = 0.39; 95% CI: 0.10 to 0.62; P = 0.013). In the maxilla seven sinus-elevated patients versus two patients treated with short implants were affected by complications, the difference not being statistically significant (difference in proportion = 0.25; 95% CI: -0.04 to 0.49; P = 0.128). Patients with mandibular short implants lost on average 1.22 mm of peri-implant bone at 5 years and patients with 10-mm or longer mandibular implants lost 1.70 mm. Patients with maxillary short implants lost on average 1.25 mm of peri-implant bone at 5 years and patients with 10-mm or longer maxillary implants lost 1.73 mm. Longer implants showed a greater bone loss up to 5 years after loading than short implants both in maxillae (mean difference: -0.48 mm; 95% CI: -0.89 to -0.07 mm; P = 0.024) and in mandibles (mean difference: -0.48 mm; 95% CI: -0.79 to -0.18 mm; P = 0.004). Conclusions: Five years after loading, 5 x 5 mm implants achieved similar results to longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation especially in posterior mandibles since the treatment is faster, cheaper and associated with less morbidity; however, 10-year post-loading data are necessary before making reliable recommendations.
  •  
13.
  •  
14.
  • Felice, P., et al. (author)
  • 1-stage versus 2-stage lateral maxillary sinus lift procedures: 4-month post-loading results of a multicenter randomised controlled trial
  • 2013
  • In: European Journal of Oral Implantology. - 1756-2406. ; 6:2, s. 153-165
  • Journal article (peer-reviewed)abstract
    • Purpose: To compare the efficacy of 1-stage versus 2-stage lateral maxillary sinus lift procedures. Materials and methods: Sixty partially edentulous patients requiring 1 to 3 implants and having 1 to 3 mm of residual bone height and at least 5 mm of bone width below the maxillary sinus, as measured on CT scans, were randomised into two equal groups to receive either a 1-stage lateral window sinus lift with simultaneous implant placement or a 2-stage procedure with implant placement delayed by 4 months using a bone substitute in 3 different centres. Implants were submerged for 4 months and loaded with reinforced provisional prostheses, which were replaced, after 4 months, by definitive prostheses. Outcome measures were augmentation procedure failures, prosthesis failures, implant failures, complications and marginal pen-implant bone loss assessed by a blinded outcome assessor. Patients were followed up to 4 months after loading. Only data of implants placed in 1 to 3 mm of bone height were reported. Results: Two patients dropped out from the 1-stage group and none from the 2-stage group. No sinus lift procedure failed in the 1-stage group but 1 failed in the 2-stage group, the difference was not statistically significant (P = 1.00). Two prostheses failed or could not be placed in the planned time in the 1-stage group and 1 in the 2-stage group, the difference was not statistically significant (P = 0.51). Three implants failed in 3 patients of the 1-stage group versus 1 implant in the 2-stage group, the difference was not statistically significant (P = 0.28). Two complications occurred in the 1-stage group and 1 in the 2-stage group, the difference was not statistically significant (P = 0.61). There were no statistically significant differences in bone loss between groups at loading (0.05 mm). Sites treated in 1 stage lost an average of 0.56mm (SD: 0.36; 95% Cl: -0.70 to -0.42; P < 0.001) of pen-implant bone and 2-stage sites approximately 0.61 mm (SD: 0.34; 95% Cl: -0.74 to -0.48; P < 0.001). Conclusions: No statistically significant differences were observed between implants placed according to 1- or 2-stage sinus lift procedures. However, this study may suggest that in patients having a residual bone height between 1 and 3 mm below the maxillary sinus there might be a slightly higher risk for implant failures when performing a 1-stage lateral sinus lift procedure.
  •  
15.
  • Felice, P., et al. (author)
  • 1-stage versus 2-stage lateral sinus lift procedures: 1-year post-loading results of a multicentre randomised controlled trial
  • 2014
  • In: European Journal of Oral Implantology. - 1756-2406. ; 7:1, s. 65-75
  • Journal article (peer-reviewed)abstract
    • Purpose: To compare the efficacy of 1-stage versus 2-stage lateral maxillary sinus lift procedures. Materials and methods: Sixty partially edentulous patients requiring 1 to 3 implants and having 1 to 3 mm of residual bone height and at least 5 mm bone width below the maxillary sinus, as measured on CT scans were selected. They were randomised according to a parallel group study design into two equal arms to receive either a 1-stage lateral window sinus lift with simultaneous implant placement or a 2-stage procedure with implant placement delayed by 4 months, using a bone substitute in three different centres. Implants were submerged for 4 months, loaded with reinforced provisional prostheses, which were replaced, after 4 months, by definitive prostheses. Outcome measures, assessed by masked assessors, were: augmentation procedure failures; prosthesis failures and implant failures; complications; and marginal pen-implant bone level changes. Patients were followed up to 1 year after loading. Only data of implants placed in 1 to 3 mm of bone height were reported. Results: Two patients dropped out from the 1-stage group and none from the 2-stage group. No sinus lift procedure failed in the 1-stage group but one failed in the 2-stage group, the difference being not statistically significant (P = 1.00). Two prostheses failed or could not be placed in the planned time in the 1-stage group and one in the 2-stage group, the difference being not statistically significant (P = 0.51). Three implants failed in three patients of the 1-stage group, versus one implant in the 2-stage group, the difference being not statistically significant (P = 0.28). Two complications occurred in the 1-stage group and one in the 2-stage group, the difference being not statistically significant (P = 0.61). One year after loading, 1-stage treated patients lost an average of -1.01 mm (SD: 0.56) of pen-implant bone and 2-stage sites about -0.93 mm (SD: 0.40). There were no statistically significant differences in bone level change between groups 1 year after loading (-0.08 mm 95%CI: -0.33 to 0.18 P = 0.56). Conclusion: No statistically significant differences were observed between implants placed according to 1- or 2-stage sinus lift procedures. However this study may suggest that in patients having residual bone height between 1 to 3 mm below the maxillary sinus, there might be a slightly higher risk for implant failures when performing a 1-stage lateral sinus lift procedure.
  •  
16.
  •  
17.
  • Felice, P., et al. (author)
  • Vertical Ridge Augmentation of an Atrophic Posterior Mandible with an Inlay Technique and Cancellous Equine Bone Block: A Case Report
  • 2013
  • In: International Journal of Periodontics & Restorative Dentistry. - 0198-7569. ; 33:2, s. 159-166
  • Journal article (peer-reviewed)abstract
    • This report describes a successful implant prosthetic rehabilitation in an atrophic left posterior mandible in a 62-year-old man using a cancellous equine bone block as grafting material. Four months later, two bone specimens were retrieved for histologic evaluation and two dental implants were placed. Computed tomography and conventional radiography showed a 5-mm mean vertical bone gain. The biopsies showed new bone formation within the cancellous portion of the blocks and no foreign body reaction. Cancellous equine bone grafts may be an effective alternative to autogenous bone and inorganic bovine bone grafting for reconstruction of the posterior mandible using the inlay technique.
  •  
18.
  • Pistilli, R., et al. (author)
  • Blocks of autogenous bone versus xenografts for the rehabilitation of atrophic jaws with dental implants: Preliminary data from a pilot randomised controlled trial
  • 2014
  • In: European Journal of Oral Implantology. - 1756-2406. ; 7:2, s. 153-171
  • Journal article (peer-reviewed)abstract
    • Objectives: To compare the effectiveness of onlay bone blocks of equine origin (test or XB group) with autogenous bone blocks (control or AB group) harvested from the ramus or the iliac crest for the rehabilitation of partially or fully edentulous atrophic jaws with implant supported prostheses. Materials and methods: Forty patients with partially or fully edentulous atrophic jaws having less than 5 mm of residual crestal bone height and/or less than 3 mm of bone thickness, as measured on computerised tomography (CT) scans, were randomised into two groups according to a parallel group design, either to be augmented with autogenous onlay bone blocks (20 patients; AB group) from the mandibular ramus or the iliac crest, or with onlays blocks of spongious bone of equine origin (20 patients; XB group). Two centres treated 20 patients each. Six XB blocks were modelled on lithographic models of the jaws before grafting. The blocks were fixed with screws and osteosynthesis plates and were covered with resorbable barriers made of equine cortical bone and fixed with tacks. The autogenous bone grafts were left to heal for 4 months and the xenografts for 7 months before placing implants, which were submerged. After 4 months, either bar-retained overdentures or provisional reinforced acrylic prostheses were delivered. Provisional prostheses were replaced, after 4 months, by definitive fixed prostheses. Outcome measures were: prosthesis and implant failures; complications; patient satisfaction; pain recorded 3 and 10 days post-augmentation; number of days of hospitalisation, total and partial infirmity days. All patients were followed for 4 months after loading. Results: All patients could be rehabilitated with implant-supported prostheses and none dropped out. Twenty-eight patients were augmented in the maxilla (15 with AB and 13 with XB) and 12 in the mandible (5 with AB and 7 with XB). No AB graft failed totally versus 10 XB grafts (difference = 0.5; 95% CI 0.23 to 0.68; P = 0.0004). In particular, all 7 XB mandibular grafts and 5 out of 6 XB blocks (3 in mandibles and 2 in maxillas), which were previously modelled on lithographic models of the jaws failed. One implant failed in one AB patient versus 11 implants in 4 XB patients (P = 0.3416). All but 1 prostheses were loaded in time in the AB patients, versus 4 prostheses which were loaded with delays in XB patients because of graft and implant failures (P = 0.3416). Four complications occurred in 4 AB patients versus 15 complications in 12 XB patients (difference = 0.4; 95% CI 0.09 to 0.63; P = 0.0225). Fourteen AB patients reported moderate pain 3 days postoperatively versus 6 XB patients (P = 0.0562); at 10 days, 10 AB patients reported moderate pain versus 1 XB patient (difference = -0.45; 95% CI -0.65 to -0.17; P = 0.0033). The 14 patients harvested from the iliac crest were hospitalised for an average of 3.1 nights, whereas 7 patients treated with XB were hospitalised on average for 1.4 nights (P < 0.0001). The number of total and partial infirmity days was 126 for the AB group and 43 for the XB group, and 220 for the AB group and 93 for the XB group, respectively (mean day difference = -4.15; 95% CI -7.35 to -0.95; P = 0.0134 and mean day difference = -5.7; 95% CI -10.01 to -1.39; P = 0.0116, respectively). Seventeen AB patients versus 19 XB patients were fully satisfied with function of their prostheses (P = 0.6050), 18 AB patients versus 12 XB patients were fully satisfied with aesthetics of their prostheses (P = 0.0648), and 5 and 3 patients, respectively would not undergo the same procedure again (P = 0.6948). There were no differences between the outcomes of the two centres with exception of prosthesis failures and complications in the maxilla. Conclusions: Autogenous onlay bone blocks are superior to equine onlay bone blocks, especially in mandibles, where all equine blocks failed, therefore we strongly discourage the use of onlay bone blocks of equine origin in mandibles.
  •  
19.
  • Pistilli, R., et al. (author)
  • Posterior atrophic jaws rehabilitated with prostheses supported by 5 x 5 mm implants with a novel nanostructured calcium-incorporated titanium surface or by longer implants in augmented bone. One-year results from a randomised controlled trial
  • 2013
  • In: European Journal of Oral Implantology. - 1756-2406. ; 6:4, s. 343-357
  • Journal article (peer-reviewed)abstract
    • Purpose: To evaluate whether 5 x 5 mm dental implants with a novel nanostructured calcium-incorporated titanium surface could be an alternative to implants at least 10 mm long placed in bone augmented with bone substitutes in posterior atrophic jaws. Materials and methods: A total of 40 patients with atrophic posterior (premolar and molar areas) mandibles having 5 to 7 mm of bone height above the mandibular canal and 40 patients with atrophic maxillae having 4 to 6 mm below the maxillary sinus, were randomised according to a parallel group design to receive one to three 5 mm implants or one to three at least 10 mm-long implants in augmented bone at two centres. All implants had a diameter of 5 mm. Mandibles were vertically augmented with interpositional bovine bone blocks and resorbable barriers. Implants were placed after 4 months. Maxillary sinuses were augmented with particulated porcine bone via a lateral window covered with resorbable barriers and implants were placed simultaneously. All implants were submerged and loaded after 4 months with provisional prostheses. Four months later, definitive screw-retained or provisionally cemented metal-ceramic or zirconia prostheses were delivered. Patients were followed up to 1 year post-loading and the outcome measures were prosthesis and implant failures, any complications and pen-implant marginal bone level changes. Results: One maxillary grafted patient dropped out before the 1-year evaluation. In mandibles, 1 grafted patient did not want to go ahead with the treatment because of multiple complications and graft failure, and another grafted patient did not receive his prostheses due the loss of 2 implants. In maxillae, one 5 x 5 mm implant failed with its provisional crown 3 months post-loading. There were no statistically significant differences in prostheses and implant failures. Significantly more complications occurred at both mandibular and maxillary grafted sites: 17 augmented patients were affected by complications versus 8 patients treated with short implants in the mandible (P = 0.0079; difference in proportion = -0.45; 95% Cl -0.67 to -0.15), and 5 sinus-lift patients versus none treated with maxillary short implants (P = 0.047; difference in proportion = -0.25; 95% Cl -0.44 to -0.06). Patients with mandibular short implants lost on average 0.94 mm of pen-implant bone at 1 year and patients with 10 mm or longer mandibular implants lost 1.03 mm. Patients with maxillary short implants lost on average 0.87 mm of pen-implant bone at 1 year and patients with 10 mm or longer maxillary implants lost 1.15 mm. There were no statistically significant differences in bone level changes up to 1 year between short and longer implants in maxillae (mean difference -0.28 mm, 95% Cl -0.56 to 0.01, P = 0.051) and in mandibles (mean difference -0.09 mm, 95% Cl -0.26 to 0.08, P = 0.295). Conclusions: One year after loading, 5 x 5 mm implants achieved similar results compared to longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation especially in posterior mandibles since the treatment is faster, cheaper and associated with less morbidity, however 5 to 10 years of post-loading data are necessary before making reliable recommendations.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-19 of 19

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view