SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Reintsema C.) "

Sökning: WFRF:(Reintsema C.)

  • Resultat 1-17 av 17
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ade, P. A. R., et al. (författare)
  • A Constraint on Primordial B-modes from the First Flight of the Spider Balloon-borne Telescope
  • 2022
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 927:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, which is an experiment that is designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. The results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency tests on these data. While the polarized CMB anisotropy from primordial density perturbations is the dominant signal in this region of sky, Galactic dust emission is also detected with high significance. Galactic synchrotron emission is found to be negligible in the SPIDER bands. We employ two independent foreground-removal techniques to explore the sensitivity of the cosmological result to the assumptions made by each. The primary method uses a dust template derived from Planck data to subtract the Galactic dust signal. A second approach, which constitutes a joint analysis of SPIDER and Planck data in the harmonic domain, assumes a modified-blackbody model for the spectral energy distribution of the dust with no constraint on its spatial morphology. Using a likelihood that jointly samples the template amplitude and r parameter space, we derive 95% upper limits on the primordial tensor-to-scalar ratio from Feldman-Cousins and Bayesian constructions, finding r < 0.11 and r < 0.19, respectively. Roughly half the uncertainty in r derives from noise associated with the template subtraction. New data at 280 GHz from SPIDER´s second flight will complement the Planck polarization maps, providing powerful measurements of the polarized Galactic dust emission.
  •  
2.
  • Bergman, A. S., et al. (författare)
  • 280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
  • 2018
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 193:5-6, s. 1075-1084
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be similar to 3 pW at 300 mK with a less than 6% variation across each array at 1 sigma. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
  •  
3.
  • Filippini, J. P., et al. (författare)
  • In-Flight Gain Monitoring of SPIDER's Transition-Edge Sensor Arrays
  • 2022
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 209:3-4, s. 649-657
  • Tidskriftsartikel (refereegranskat)abstract
    • Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical response that is exact in the limit of strong electrothermal feedback. We discuss the application and validation of this method using flight data from SPIDER, a balloon-borne telescope that observes the polarization of the cosmic microwave background with more than 2000 TESs. This method may prove useful for future balloon- and space-based instruments, where observing time and ground control bandwidth are limited.
  •  
4.
  • Leung, J. S.-Y., et al. (författare)
  • A Simulation-based Method for Correcting Mode Coupling in CMB Angular Power Spectra
  • 2022
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 928:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Modern cosmic microwave background (CMB) analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-C-l based, MASTER-style analyses, the net effect of the time-domain filtering is commonly approximated by a multiplicative transfer function, F-l , that can fail to capture mode mixing and is dependent on the spectrum of the signal. To address these shortcomings, we have developed a simulation-based spectral correction approach that constructs a two-dimensional transfer matrix, J(ll'), which contains information about mode mixing in addition to mode attenuation. We demonstrate the application of this approach on data from the first flight of the Spider balloon-borne CMB experiment.
  •  
5.
  • Gambrel, A. E., et al. (författare)
  • The XFaster Power Spectrum and Likelihood Estimator for the Analysis of Cosmic Microwave Background Maps
  • 2021
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 922:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the XFaster analysis package, a fast, iterative angular power spectrum estimator based on a diagonal approximation to the quadratic Fisher matrix estimator. It uses Monte Carlo simulations to compute noise biases and filter transfer functions and is thus a hybrid of both Monte Carlo and quadratic estimator methods. In contrast to conventional pseudo-Cℓ–based methods, the algorithm described here requires a minimal number of simulations and does not require them to be precisely representative of the data to estimate accurate covariance matrices for the bandpowers. The formalism works with polarization-sensitive observations and also data sets with identical, partially overlapping, or independent survey regions. The method was first implemented for the analysis of BOOMERanG data and also used as part of the Planck analysis. Here we describe the full, publicly available analysis package, written in Python, as developed for the analysis of data from the 2015 flight of the Spider instrument. The package includes extensions for self-consistently estimating null spectra and estimating fits for Galactic foreground contributions. We show results from the extensive validation of XFaster using simulations and its application to the Spider data set.
  •  
6.
  • Gualtieri, R., et al. (författare)
  • SPIDER : CMB Polarimetry from the Edge of Space
  • 2018
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 193:5-6, s. 1112-1121
  • Tidskriftsartikel (refereegranskat)abstract
    • SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. Spider targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. SPIDER's first long-duration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled transition-edge sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the SPIDER instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. SPIDER's second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.
  •  
7.
  • Nagy, J. M., et al. (författare)
  • A New Limit on CMB Circular Polarization from SPIDER
  • 2017
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 844:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a new upper limit on cosmic microwave background (CMB) circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for B-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the nonzero circular-to-linear polarization coupling of the half-wave plate polarization modulators, data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes V at 95 and 150 GHz in the range 33 < l < 307. No other limits exist over this full range of angular scales, and SPIDER improves on the previous limit by several orders of magnitude, providing 95% C.L. constraints on l (l + 1)C-l(VV) /(2 pi) ranging from 141 to 255 mu K-2 at 150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments become increasingly sensitive, the techniques described in this paper can be applied to obtain even stronger constraints on circular polarization.
  •  
8.
  • Osherson, B., et al. (författare)
  • Particle Response of Antenna-Coupled TES Arrays : Results from SPIDER and the Laboratory
  • 2020
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 199:3-4, s. 1127-1136
  • Tidskriftsartikel (refereegranskat)abstract
    • Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce 'glitches' in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.
  •  
9.
  • Hashimoto, T., et al. (författare)
  • Beamline test of a transition-edge-sensor spectrometer in preparation for kaonic-atom measurements
  • 2017
  • Ingår i: IEEE Transactions on Applied Superconductivity. - 1051-8223. ; 27:4
  • Tidskriftsartikel (refereegranskat)abstract
    • We are developing a new technique to apply transition-edge sensors (TESs) to X-ray spectroscopy of exotic atoms, especially of kaonic atoms. To demonstrate the feasibility of this pioneering project, performance of a TES-based X-ray detector was evaluated in pion- and kaon-beam environments at particle accelerators.We successfully observed X-rays from pionic-carbon atoms with a resolution as good as 7 eV FWHM at 6 keV. Also at a kaon beamline, we confirmed that the TES spectrometer will be able to achieve our resolution goal, 6 eV, in our first scientific campaign to measure X-rays from kaonic-helium atoms.
  •  
10.
  • Hashimoto, T., et al. (författare)
  • Kaonic-Atom X-ray Spectroscopy with Superconducting Microcalorimeters
  • 2017
  • Ingår i: Proceedings of the 12th International Conference on Hypernuclear and Strange Particle Physics (HYP2015). - 9784890271221 ; 17
  • Konferensbidrag (refereegranskat)abstract
    • We will measure kaonic helium X-rays using transition-edge-sensor microcalorimeters, TES, in the J-PARC hadron experimental facility. To demonstrate the feasibility of the experiment, we performed a measurement of pionic carbon X-rays at PSI, where an excellent FWHM energy resolution of 7 eV at 6.4 keV was achieved. We also evaluated the expected TES performance in the kaon beam at J-PARC. The simulation results show that the TES spectrometer would work with a good energy resolution, and clear peaks of kaonic helium X-rays would be observed on a reasonably suppressed background.
  •  
11.
  • Doriese, W B, et al. (författare)
  • A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science
  • 2017
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 88:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.
  •  
12.
  • Okada, S., et al. (författare)
  • First application of superconducting transition-edge sensor microcalorimeters to hadronic atom X-ray spectroscopy
  • 2016
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; 2016:9
  • Tidskriftsartikel (refereegranskat)abstract
    • High-resolution pionic atom X-ray spectroscopy was performed with an X-ray spectrometer based on a 240 pixel array of superconducting transition-edge sensor (TES) microcalorimeters at the φM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f → 3d transition and the parallel 4d → 3p transition were observed with a full width at half maximum energy resolution of 6.8 eV at 6.4 keV. The measured X-ray energies are consistent with calculated electromagnetic values which considered the strong interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic atom X-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic atom X-ray spectroscopy.
  •  
13.
  •  
14.
  • Uhlig, Jens, et al. (författare)
  • High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential.
  • 2015
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 22:Pt 3, s. 766-775
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.
  •  
15.
  • O’Neil, Galen C., et al. (författare)
  • Ultrafast Time-Resolved X-ray Absorption Spectroscopy of Ferrioxalate Photolysis with a Laser Plasma X-ray Source and Microcalorimeter Array
  • 2017
  • Ingår i: The Journal of Physical Chemistry Letters. - : American Chemical Society (ACS). - 1948-7185. ; 8:5, s. 1099-1104
  • Tidskriftsartikel (refereegranskat)abstract
    • The detailed pathways of photoactivity on ultrafast time scales are a topic of contemporary interest. Using a tabletop apparatus based on a laser plasma X-ray source and an array of cryogenic microcalorimeter X-ray detectors, we measured a transient X-ray absorption spectrum during the ferrioxalate photoreduction reaction. With these high-efficiency detectors, we observe the Fe K edge move to lower energies and the amplitude of the extended X-ray absorption fine structure reduce, consistent with a photoreduction mechanism in which electron transfer precedes disassociation. These results are compared to previously published transient X-ray absorption measurements on the same reaction and found to be consistent with the results from Ogi et al. and inconsistent with the results of Chen et al. (Ogi, Y.; et al. Struct. Dyn. 2015, 2, 034901; Chen, J.; Zhang, H.; Tomov, I. V.; Ding, X.; Rentzepis, P. M. Chem. Phys. Lett. 2007, 437, 50-55). We provide quantitative limits on the Fe-O bond length change. Finally, we review potential improvements to our measurement technique, highlighting the future potential of tabletop X-ray science using microcalorimeter sensors.
  •  
16.
  • Uhlig, Jens, et al. (författare)
  • Table-Top Ultrafast X-Ray Microcalorimeter Spectrometry for Molecular Structure
  • 2013
  • Ingår i: Physical Review Letters. - 1079-7114. ; 110:13
  • Tidskriftsartikel (refereegranskat)abstract
    • This work presents an x-ray absorption measurement by use of ionizing radiation generated by a femtosecond pulsed laser source. The spectrometer was a microcalorimetric array whose pixels are capable of accurately measuring energies of individual radiation quanta. An isotropic continuum x-ray spectrum in the few-keV range was generated from a laser plasma source with a water-jet target. X rays were transmitted through a ferrocene powder sample to the detector, whose pixels have average photon energy resolution Delta E = 3.14 eV full-width-at-half-maximum at 5.9 keV. The bond distance of ferrocene was retrieved from this first hard-x-ray absorption fine-structure spectrum collected with an energy-dispersive detector. This technique will be broadly enabling for time-resolved observations of structural dynamics in photoactive systems. DOI: 10.1103/PhysRevLett.110.138302
  •  
17.
  • Ullom, J N (creator_code:cre_t)
  • X-ray Spectrometer
  • 2019
  • Patent (övrigt vetenskapligt/konstnärligt)abstract
    • An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-17 av 17

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy