SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Shon H. K.) "

Sökning: WFRF:(Shon H. K.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaltonen, T., et al. (författare)
  • Combination of Tevatron Searches for the Standard Model Higgs Boson in the W+W- Decay Mode
  • 2010
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 104:6, s. 061802-
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine searches by the CDF and D0 Collaborations for a Higgs boson decaying to W+W-. The data correspond to an integrated total luminosity of 4.8 (CDF) and 5.4 (D0) fb(-1) of p (p) over bar collisions at root s = 1.96 TeV at the Fermilab Tevatron collider. No excess is observed above background expectation, and resulting limits on Higgs boson production exclude a standard model Higgs boson in the mass range 162-166 GeV at the 95% C.L.
  •  
2.
  • Shard, A. G., et al. (författare)
  • Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study
  • 2015
  • Ingår i: Journal of Physical Chemistry B. - : American Chemical Society (ACS). - 1520-6106 .- 1520-5207. ; 119:33, s. 10784-10797
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray photoelectron spectroscopy (XPS) or time-of-flight secondary ion mass spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants' data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally, we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.
  •  
3.
  • Karlsson, T., et al. (författare)
  • Gluteal lymphoedema associated with lower extremity lymphoedema : A preliminary study with indocyanine green lymphography and magnetic resonance imaging
  • 2023
  • Ingår i: Journal of Plastic, Reconstructive and Aesthetic Surgery. - : Elsevier BV. - 1748-6815. ; 76, s. 88-93
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Indocyanine green (ICG) lymphography studies have identified that one in three to five patients with cancer-related lower extremity lymphoedema (LEL) demonstrated dermal backflow extending to the gluteal region. This study aimed to further characterize gluteal lymphoedema using contemporaneous magnetic resonance imaging (MRI). Patients and methods: Twenty-eight patients with unilateral advanced LEL who underwent both ICG lymphography and MRI prior to any surgical procedure were included in this study. The patients were divided into two groups with/without gluteal lymphoedema by the presence of dermal backflow on ICG lymphography. MRI was used to evaluate tissue changes. Results: Ten patients demonstrated gluteal lymphoedema on ICG lymphography and had a higher incidence of skin hypertrophy in the gluteal region. However, no difference in excess leg volume was found between the two groups. A trend of increasing gluteal subcutaneous tissue in the affected side was identified in patients with gluteal lymphoedema with a median increase of 20% compared with an 11% increase in the non-gluteal lymphoedema group. The excess gluteal subcutaneous tissue was positively correlated to ipsilateral excess leg volume. Conclusion: The gluteal lymphoedema group on ICG lymphography had skin thickening in the gluteal region and was likely identified in the secondary cancer-related group. Surgical and conservative management options for gluteal lymphoedema need to be considered in advanced LEL.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy