SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sobiella M.) "

Sökning: WFRF:(Sobiella M.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Adamczewski-Musch, J., et al. (författare)
  • Production and electromagnetic decay of hyperons : a feasibility study with HADES as a phase-0 experiment at FAIR
  • 2021
  • Ingår i: European Physical Journal A. - : Springer Nature. - 1434-6001 .- 1434-601X. ; 57:4
  • Tidskriftsartikel (refereegranskat)abstract
    • A feasibility study has been performed in order to investigate the performance of the HADES detector to measure the electromagnetic decays of the hyperon resonances Sigma(1385)(0), Lambda(1405) and Lambda(1520) as well as the production of double strange baryon systems Xi(-) and Lambda Lambda in p + p reactions at a beam kinetic energy of 4.5GeV. The existing HADES detector will be upgraded by a new Forward Detector, which extends the detector acceptance into a range of polar angles that plays a crucial role for these investigations. The analysis of each channel is preceded by a consideration of the production cross-sections. Afterwards the expected signal count rates using a target consisting of either liquid hydrogen or polyethylene are summarized.
  •  
3.
  • Pausch, G., et al. (författare)
  • RoSiB - a 4 pi silicon ball for charged-particle detection in EUROBALL
  • 2000
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 443:03-feb, s. 304-318
  • Tidskriftsartikel (refereegranskat)abstract
    • A 4 pi silicon bail for detection and identification of light charged particles in large multidetector gamma-arrays as EUROBALL is presented. The design is based on a N = 42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive material for gamma-rays is minimized to the detector thickness of 300 or 500 mu m and a 0.63 mm ceramic backing. The geometrical coverage is designed for about 90% of 4 pi. A pulse shape discrimination method with totally depleted detectors working in the reverse mount allows identifying protons and alpha-particles above an energy threshold of about 2 MeV. The performances of the ball were rested at the tandem - booster accelerator combination of the MPI Heidelberg in two experiments using the high-recoil reaction of 228 MeV Ni-58 + Ti-46 and the low-recoil reaction of 95 MeV O-16 + Ni-58. The two-dimensional spectra of zero-crossing (ZC) versus energy confirmed an excellent discrimination of protons and alpha-particles in all the detectors at different angles. The energy spectra of protons and alpha-particles measured in the experiments are presented. too. The gamma-spectra measured in coincidence with various combinations of emitted particles showed a high selectivity of the ball. The reduced total efficiency for protons of 59% and 55% and alpha-particles of 44% and 32% measured in a nuclear spectroscopy application is analyzed in a Monte-Carlo simulation (GEANT). It is due to a combined influence of a thick target needed to stop the recoiling residual nuclei and thick absorbers needed to protect the Si-detectors from scattered beam. The results along with the GEANT extrapolation to optimum experimental conditions confirm that RoSiB is a highly efficient and selective device for identification of rare reaction channels with heavy ions.
  •  
4.
  • Pausch, G, et al. (författare)
  • RoSiB - a 4 pi silicon ball for charged-particle detection in EUROBALL
  • 2000
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : ELSEVIER SCIENCE BV, AMSTERDAM. - 0168-9002. ; 443:2-3, s. 304-318
  • Tidskriftsartikel (refereegranskat)abstract
    • A 4 pi silicon bail for detection and identification of light charged particles in large multidetector gamma-arrays as EUROBALL is presented. The design is based on a N = 42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive
  •  
5.
  • Roeder, M., et al. (författare)
  • Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons
  • 2014
  • Ingår i: European Physical Journal A. - : Springer Science and Business Media LLC. - 1434-6001 .- 1434-601X. ; 50:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Composite detectors made of stainless-steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175 MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy