SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wearing G.) "

Sökning: WFRF:(Wearing G.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • George, T. S., et al. (författare)
  • Organic phosphorus in the terrestrial environment : a perspective on the state of the art and future priorities
  • 2018
  • Ingår i: Plant and Soil. - : Springer Netherlands. - 0032-079X .- 1573-5036. ; 427:1-2, s. 191-208
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The dynamics of phosphorus (P) in the environment is important for regulating nutrient cycles in natural and managed ecosystems and an integral part in assessing biological resilience against environmental change. Organic P (P-o) compounds play key roles in biological and ecosystems function in the terrestrial environment being critical to cell function, growth and reproduction.Scope: We asked a group of experts to consider the global issues associated with P-o in the terrestrial environment, methodological strengths and weaknesses, benefits to be gained from understanding the P-o cycle, and to set priorities for P-o research.Conclusions: We identified seven key opportunities for P-o research including: the need for integrated, quality controlled and functionally based methodologies; assessment of stoichiometry with other elements in organic matter; understanding the dynamics of P-o in natural and managed systems; the role of microorganisms in controlling P-o cycles; the implications of nanoparticles in the environment and the need for better modelling and communication of the research. Each priority is discussed and a statement of intent for the P-o research community is made that highlights there are key contributions to be made toward understanding biogeochemical cycles, dynamics and function of natural ecosystems and the management of agricultural systems.
  •  
2.
  • Conway, N. J., et al. (författare)
  • The MAST motional Stark effect diagnostic
  • 2010
  • Ingår i: REVIEW OF SCIENTIFIC INSTRUMENTS. - Melville, NY : AMER INST PHYSICS. - 1089-7623. ; , s. 10D738-
  • Konferensbidrag (refereegranskat)abstract
    • A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of similar to 2.5 cm, and time resolution of similar to 1 ms at angular noise levels of similar to 0.5 degrees. Conventional (albeit very narrow) interference filters isolate pi or sigma polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The pi component is observed to be significantly stronger than sigma, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on pi. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.
  •  
3.
  • Kuldkepp, Matias, et al. (författare)
  • Motional Stark effect diagnostic pilot experiment for MAST
  • 2006
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 77:10, s. 10E905-
  • Tidskriftsartikel (refereegranskat)abstract
    • Exploiting the motional Stark effect (MSE) in the low magnetic fields of spherical tokamaks such as MAST is complicated by the Doppler smearing of the relatively closely spaced Stark components. Extensive modeling of MSE spectra and the subsequent polarized fraction (similar to 20%) of spectrally filtered light and signal to noice ratios have been performed taking account of real experimental conditions including neutral beam parameters, port sizes, optical losses, filter characteristics, etc. A design is selected which uses high throughput interference filters (0.1 nm bandpass ) for separation of the spectral components. An accuracy of similar to 0.5 degrees S compared with typically 15 degrees is estimated for field angle measurements. The design allows for early implementation, starting with a pilot two chord system, and for an economic expansion to a multiplicity of chords. Matching the Doppler shifted D-alpha from the beam neutrals will be accomplished by a combination of filter selection and fine-tuning of the beam voltage. Avoiding filter tuning in the design greatly simplifies the diagnostic. Calibration results of the diagnostic support the calculations.
  •  
4.
  • Gillespie, S. A., et al. (författare)
  • Identification of sub- μ s isomeric states in the odd-odd nucleus Au 178
  • 2021
  • Ingår i: Physical Review C. - 2469-9985. ; 103:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The neutron-deficient gold (Z=79) isotopes in the vicinity of the neutron midshell N=104 provide prolific examples of shape coexistence and isomerism at low excitation energy. They can be probed via a number of different experimental techniques. In this study, two new isomeric states with half-lives of 294(7) and 373(9) ns have been observed in the neutron-deficient odd-odd nuclide Au178 (N=99) in an experiment at the RITU gas-filled separator at JYFL, Jyväskylä. This result was achieved due to the use of a segmented planar germanium detector with a high efficiency at low energies. By applying the recoil-decay tagging technique, they were assigned to decay to two different long-lived α-decaying states in Au178.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy