SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Worm Esben) "

Sökning: WFRF:(Worm Esben)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bernigaud, Virgile, et al. (författare)
  • Electron capture-induced dissociation of AK dipeptide dications : Influence of ion velocity, crown-ether complexation and collision gas
  • 2008
  • Ingår i: International Journal of Mass Spectrometry. - : Elsevier BV. - 1387-3806 .- 1873-2798. ; 276:2-3, s. 77-81
  • Tidskriftsartikel (refereegranskat)abstract
    • The fragmentation of doubly protonated AK dipeptide ions has been investigated after collisional electron transfer. Electron capture leads to three dominant channels, H loss, NH3 loss, and N–Cα bond breakage to give either c+ or z+ fragment ions. The relative importance of these channels has been explored as a function of ion velocity, the degree of complexation with crown ether, and collision gas. Our results indicate that H loss and NH3 loss are competing channels whereas the probability of N–Cα bond breakage is more or less constant.
  •  
2.
  • Colvill, Emma, et al. (författare)
  • A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy : A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking
  • 2016
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140. ; 119:1, s. 159-165
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion. Methods and materials Ten institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for γ-tests recorded. Results For all lung traces all measurement sets show improved dose accuracy with a mean 2%/2 mm γ-fail rate of 1.6% with adaptation and 15.2% without adaptation (p < 0.001). For all prostate the mean 2%/2 mm γ-fail rate was 1.4% with adaptation and 17.3% without adaptation (p < 0.001). The difference between the four systems was small with an average 2%/2 mm γ-fail rate of <3% for all systems with adaptation for lung and prostate. Conclusions The investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy